The NCRA1 series is a rack and pinion rotary actuator, which offers very high torque-to-size and accurate positioning. Rail type mounting allows switch position to be easily adjusted. Bore sizes available include 30, 50, 63, 80 and 100mm. Single rod end or double rod end models are available.Standard type rotary actuator, Single or double rod end available, Bore sizes: 50mm ~ 100mm, Mounting
The MGZ series is a non-lube double power air cylinder available in both rotating and non-rotating styles. The MGZ's unique design doubles the pressurized area for extension making the MGZ an ideal cylinder for lifting and pressing operations. The front end lock style MGZ holds the rod when extended. Non-rotating, double power cylinder with rod-side end lock, Bore sizes (mm): 40, 50, 63,
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: E (Simple Joint B Type + Joint)
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: TF (Bore 20: M5 Thread, Bore 32 to 50: G), Stroke: 25mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal
Magnet: D (Built-in), Rod Type: Standard, Mounting: L (Foot), Bore Size: 50mm, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 16mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 25mm, Body Option: Rod End Female Thread, Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: D (Built-in Magnet), Mounting: B (Standard, Through-hole), Bore Size: 32mm, Stroke 1: 25mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector
Magnet: D (Built-in Magnet), Mounting: B (Standard, Through-hole), Bore Size: 25mm, Stroke 1: 25mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),
Magnet: D (Built-in Magnet), Mounting: B (Standard, Through-hole), Bore Size: 32mm, Stroke 1: 25mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),
Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of
Bore Size: 25mm, Opening & Closing Stroke: Standard
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 25mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 25mm, Body Option: Rod End Female Thread, Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 20mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 25mm, Body Option: Rod End Female Thread, Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch