Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% 1 Electric spec.
Black Continuous Energization (24 VDC) Black 1. Power consumption 80 W specification: Not possible When operating with an energy saving driver, continuous energization with the holding voltage of 3 to 6 VDC is possible. Symbol 2.
valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Insulation type Photo coupler insulation type Residual voltage 0.4 VDC or less -25No.EX-OMN0011-F Network communication specifications Item Specifications Protocol EtherCAT EtherCAT mode Direct Mode (No MAC address) : Does not support Open Mode.
Cable colour: Signal Cable O.D. 5.0 mm 1 Brown : 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) 3 Blue : 24 VDC (For control) Wire diameter (Including insulator) 1.27 mm 4 Black : 0 V (For control) 5 Green/Yellow: Not connected Min. bending radius (Fixed) 21.7 mm -31No.EX-OMP0005-I Seal cap For M12 connector socket: 10 pcs.
Supply 24 VDC 10% to the power supply for the input and control.
Current consumption in power supply voltage range 22.8 to 26.4 VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve power supply EX260-SPR1/-SPR3/-SPR5/-SPR7 PNP (negative common) / source Output type EX260-SPR2/-SPR4/-SPR6/-SPR8 NPN (positive common) / sink Solenoid valve connecting specification Solenoid valve with surge voltage suppressor of 24 VDC and
System error (Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 24 VDC 10%. (2) Supply power in the range 12 to 24 VDC 10%. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range.
condition at the time of communication error Output HOLD/CLEAR Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 1.5 W or less (manufactured by SMC) Insulation type Photo coupler insulation type Residual voltage 0.4 VDC or less -36No.EX-OMP0013-E Communication specifications Item Specifications Protocol Ethernet (IEEE802.3) Transmission medium Standard Ethernet cable
on NVS 3125) 48 VDC Poitlng 01 = 1/8" NPTF (NVS 3125 only) Cv 069 02 = 1/4' NPTF (NVS 3125 only) Cv 0.8i!
Electrical entry direction Perpendicular Perpendicular Perpendicular 3-wire Wiring type 2-wire Output type NPN PNP IC circuit, 24 VDC relay, PLC Applicable load 24 VDC relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) Power supply voltage 10 mA or less Current consumption Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA 80 mA or less 1.5 V or less (0.8
Supply source voltage Check if source voltage within the specification range (24 VDC 10%) is supplied. How to reset the product for power cut or forcible de-energizing Supply power to the product. The output status just before the power failure is not maintained when power supply is recovered.
Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.
-made) Cable: 16AWG 1 1 24 VDC + Wire color Contents 2 Brown 24 VDC + Power connector Blue 24 VDC J.S.T. Mfg. Co., Ltd.
Electrical entry direction In-line Wiring type 2-wire 3-wire NPN PNP Output type Applicable load IC circuit, relay, and PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less Load current 2.5 to 40 mA 40 mA or less Internal voltage drop 4 V or less 0.8 V or less at 10 mA (2V or less at
Check if there is a noise source An over current (2)Check if the power supply error (Er1 and 2) is indicated. voltage is in the range of 12 to 24 VDC. (2)Supply power voltage of 12 to 24 VDC.
System error (Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 24 VDC 10%. (2) Supply power in the range 12 to 24 VDC 10%. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range.
Connector pin numbers (lead wire) Used as switch output device Pin number Wire colour Description Function 1 Brown DC(+) 24 VDC 2 White FUNC Analogue output or External input 3 Blue DC(-) 0 V 4 Black OUT Switch output Used as IO-Link device Pin number Wire colour Description Function 1 Brown DC(+) 21.6 to 30 VDC 2 White N.C.
or more Enclosure IP67 Standard CE marked (EMC directive, RoHS directive), UL (CSA) Weight 250 g or less Electric specifications Item Specifications Applicable system DeviceNet Release2.0 SI unit power supply (V) and current consumption Conforms to the DeviceNet specifications (11 to 25 VDC) 100 mA or less Power supply voltage range and current consumption 19.2 to 28.8 VDC Depends on the
. -11No.EX-OMI0032-G Common Specifications EX510 series common specifications Item Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal
Incorrect operation of the internal data of the Pressure switch (Er0, Er4, Er6, Er7, Er8, Er9) System error (Er0, Er4, Er6, Er7, Er8 or Er9) is displayed. (2) Check that the power supply voltage is within the range 12 to 24 VDC 10%. (2) Supply a correct voltage of 12 to 24 VDC 10%.