SMC Corporation of America
Elite Part Number Search
Search Results "LECP1P1-LEFS40A-1000"

lead wire and case) Withstand voltage 10 to 60C Ambient temperature IEC60529 Standard IP67 (2) Enclosure 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C): 1000 VAC/min.

The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) V(mm/s) = x 1000 4. Keep wiring as short as possible. Although wire length should not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch.

(between lead wire and case) 1000 VAC for 1 min.

Auto switch operating range (mm) _ Load operating time V(mm/s) = x 1000 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life. (The switch will stay ON all the time.) 1) Use a contact protection box when the wire length is 5m or longer. 7.

Screw lead LC1-1(Either T-nuts or T-brackets for mounting) LC1-1-1000 (Controller connector) LC1-1-2000 (Controller connector) (Refer to page 85.) F H L 6mm 10mm 20mm Note) The following options are necessary for operating and setting the controller.

] 0.3 Rotational torque [N.m] MQR12 MQR8 MQR8 20 MQR4 MQR2 MQR12 0.2 10 0.1 MQR1 0 0 0 1000 2000 3000 0 500 1000 1500 2000 2500 3000 Rotation speed [min-1 (r.p.m)] Rotation speed [min-1 (r.p.m)] Note 1: Value when no pressure applied.

B80CL N (Example) B80CN * : Manufactured upon receipt of order Stroke Long stroke (mm) Standard stroke (mm) Model Bearing Bore size (mm) 20 25 32 40 50 75, 100, 125, 150, 200 250, 300, 350, 400 MGCM Slide bearing 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000

V = 2gH/1000 x 60 20 12 = 2 x 9.8 x 15/1000 x 60 = 32.5 (m/min) 20 L=60mm 20 L=50mm . Obtain the intersection of the collision speed V and the total weight of the work piece m. Confirm that the value is within the operating range of the point of application L = 60mm.

Lead wire length 2000 mm Cover Concave Pin Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lever DC indicator Socket Part no.

Lead wire length 2000 mm -+ Socket Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lead wire Connector Hook For DC V114-5LO SY100-30-4A-20 For AC V114A-1LO SY100-30-1A-20 2.

For lead wire length (1000 mm) Solenoid valve: VZ2150-5M0-015 pcs. Connector assembly: DXT170-80-4A-105 pcs. Crimping the Lead Wire and Socket Peel 3.2 to 3.7 mm of the tip of lead wire, enter the core wires neatly into a socket and crimp it with a special crimp tool. Be careful so that the cover of lead wire does not enter into the crimping part.

Cylinder Speed Chart Bore size Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm Series MB, CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Enclosure Series Average speed (mm/s) IP65 compatible T kit (Terminal block box) 5 wiring types have been standardized to facilitate easy wiring work and maintenance.

Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" Flow rate (l/min (ANR)) OUT 1000 680 440 480 420 210 150 IN OUT IN High pressure Effective area (mm2) 15.2 10.4 6.7 7.3 6.4 3.2 2.3 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation

mm/s50 to 1000 mm/s100 to 1000 mm/sHeavy load0.25 to 2.45 m/s26 (10) kg11 (20) kgTrapezoidal driveHorizontal directionBoth ends (Mechanical stoppers), 1 intermediate positionBoth ends (Mechanical stoppers), 3 intermediate positionsBoth endsIntermediate stopping position10 N20 NDirect teaching, JOG teachingController bodyLED for power supply, LED for alarming, LED for positioning completionActuation