Available in thread sizes from M3 to 1/2 in both inch (NPT) and metric R(PT) and with tube sizes from 3.2mm to 12mm OD (metric) and 1/8 to 1/2 OD (inch) and with optional elbow and universal style (increased flexibility) and meter-in and meter-out, these speed controls are designed to meet most applications.
°C), Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: Rc, Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: B (Out 1: PNP; Out 2: PNP), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)
), Vacuum Pressure Sensor: None, Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
), Vacuum Pressure Sensor: None, Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Sensor: None, Output: A (NPN Open Collector), Unit: M (SI Unit Only, kPa), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Sensor: None, Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector)
Sensor: None, Output: A (NPN Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: without Sealant, Push lock: A (Push-lock)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 06 (ø6), Sealant: S (with Sealant), Push lock: A (Push-lock)
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 06 (ø6mm), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: One Touch Fitting Class 1: ø4, Class 2~5: ø6, Pilot Port Position: None (Position 1), Material: Standard, Option: 1 (With Flow Rate Adjustment)
Body Class: 2 (Orifice Dia. ø4), Valve Type: 0 (N.C.), Applicable Tubing Size: 06 (ø6mm), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: 2 (M5X0.8)