Head Flange (mm) Bore size (mm) Standard stroke A AL D J B B1 C H1 H ZZ E F FX FD FT GA GB I KA MM NA P S 20 25 32 40 50 63 80 100 12 12.5 11 10.5 15 15 17 20 85 92 94 101 130 130 162 166 14.5 17.5 17.5 23.5 29 29 35.5 35.5 5 6 6 8 11 11 13 16 14 16.5 20 26 32 38 50 60 20 23 23 29 35 35 44 44 Up to 200 12 15 15 20.5 26 26 32.5 32.5 40 44 53 61 76 92 104 128 13 17 17 19 27 27 32 41 8 10 12
For dimensions of 25 stroke, refer to page 8-26-20. 12.5 15 15 10.5 12.5 15 15 10 23 23 12.5 15 12.5 15 15 17.5 15 17.5 15 17.5 15 17.5 9 17.5 14 16 22 23 23 24 22 23 23 24 Note 2) For 25 stroke, the shock absorber is mounted on a single side of the plate.
L dimension 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 285.5 21 273 No.
A Unused A Unused A Unused A Unused A Unused A B A B A B A B A B A A A B A B A B A B A A VQC 10 11 13 12 15 14 11 10 12 13 14 15 SQ 9 8 7 6 5 4 3 2 1 0 3 2 1 0 4 5 9 8 7 6 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System VQ0 VQ4 Name of terminal block (LED) Note ADDRESS NO. STATION NO.
K2 H6 EU 11 11 15 15 18 18 10 12 12 16 16 20 6.6 6.6 9 9 11 11 38 41 50 52 66 76 51 54 65 67 86 96 10 10 12 14 18 20 21 24 33 37 47 55 7 9 11 11 12.5 13.5 18 22 30 35 40 50 26 28 32 40 50 60 31 35 45 50 60 70 32 36 45 50 63 71 8 10 12 12 14 15 10 11 12 15 15 19 32 40 50 63 80 100 11 11 15 15 18 18 10 12 16 16 20 20 21 24 33 37 47 55 8.5 8.5 10.5 10.5 11.5 12.5 10 10 12 12 14 15 6.6 6.6 9
[mm] Model L A B n C D E Without lock With lock 11-LEJS40S-200523.5 563.5 206 260 6 1 200 80 11-LEJS40S-300623.5 663.5 306 360 6 1 200 180 11-LEJS40S-400723.5 763.5 406 460 8 2 400 80 11-LEJS40S-500823.5 863.5 506 560 8 2 400 180 11-LEJS40S-600923.5 963.5 606 660 10 3 600 80 11-LEJS40S-7001023.5 1063.5 706 760 10 3 600 180 11-LEJS40S-8001123.5 1163.5 806 860 12 4 800 80 11-LEJS40S-9001223.5
11 11 23 11 23 SOL.A SOL.B SOL.B Light/Surge voltage suppressor Station 10 Station 10 SOL.A SOL.A 10 10 Light/Surge voltage suppressor Light/Surge voltage suppressor 15 15 15 SOL.B SOL.B SOL.B Station 2 Station 2 Station 2 2 2 SOL.A SOL.A SOL.A Light/Surge voltage suppressor Light/Surge voltage suppressor Light/Surge voltage suppressor 2 SOL.B SOL.B SOL.B 14 Station 1 Station 1 14 14 Station
10.5 D-Z7/Z80 7.5 8.5 7.5 9.5 9.5 10.5 D-A5/A6 9 9 10 11 11 11 D-A59W 13 13 13 14 14 15 D-A3/A44 9 9 10 11 11 11 *1 The switch mounting bolt is supplied with the switch. * Values which include hysteresis are for reference purposes only.
14 3 2 1 4 SOL.A 17 16 5 25 24 Station 3 13 SOL.B 6 23 18 12 4 SOL.A 7 26 22 19 Station 4 SOL.B 11 5 21 20 8 SOL.A 10 9 8 7 6 The total number of stations is tabulated starting from station one on the D-side. 9 Station 5 SOL.B 10 SOL.A 11 Station 6 SOL.B 12 SOL.A 13 Station 7 SOL.B 14 SOL.A 15 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/
14 3 2 1 4 SOL.A 17 16 5 25 24 Station 3 13 SOL.B 6 23 18 12 4 SOL.A 7 26 22 19 Station 4 SOL.B 11 5 21 20 8 SOL.A 10 9 8 7 6 The total number of stations is tabulated starting from station one on the D-side. 9 Station 5 SOL.B 10 SOL.A 11 Station 6 SOL.B 12 SOL.A 13 Station 7 SOL.B 14 SOL.A 15 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/
XLGV/With solenoid valve Q Port R (exhaust port) N N With double solenoid P K M L (mm) L 6.5 6.5 6.5 11 11 11 K 9 9 9 11 11 11 N 14 Model K L M N P Q M 17 15 2 6 Q 16.5 16.5 17.5 28 29 29 P Model XLGV-16 XLGV-25 XLGV-40 XLGV-50 XLGV-63 XLGV-80 3 3 3 6.5 6.5 6.5 16 With single solenoid Port P (pressure port) 29 26 32 45 Other dimensions are the same as XLG. 19 Series XLD, XLDV Smooth Exhaust
/32 9/32 1.43 1 1.71 3 5/8 2.36 6.44 5/8 1 15/16 2 1/4 1.81 M16x1.5 200 (2") 5/8 7/16-20 3/4 2.6 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3/8 1.26 1.06 11/32 11/32 1.84 1 1.71 3 5/8 2.40 6.44 7/8 1 15/16 2 1/4 1.81 M16x1.5 250 (2.5") 5/8 7/16-20 3/4 3.1 1 1/8 3/8 9/16 5/16-24 3 0 3/8 1.30 1.06 11/32 11/32 2.19 1 1.75 3 3/4 2.48 6.44 1 1/4 1 15/16 2 3/8 1.69 M16x1.5 325 (3.25") 1 3/4-16 1 1/8 3.9
/32 9/32 1.43 1 1.71 3 5/8 2.36 6.44 5/8 1 15/16 2 1/4 1.81 M16x1.5 200 (2") 5/8 7/16-20 3/4 2.6 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3/8 1.26 1.06 11/32 11/32 1.84 1 1.71 3 5/8 2.40 6.44 7/8 1 15/16 2 1/4 1.81 M16x1.5 250 (2.5") 5/8 7/16-20 3/4 3.1 1 1/8 3/8 9/16 5/16-24 3 0 3/8 1.30 1.06 11/32 11/32 2.19 1 1.75 3 3/4 2.48 6.44 1 1/4 1 15/16 2 3/8 1.69 M16x1.5 325 (3.25") 1 3/4-16 1 1/8 3.9
6 16 11 8 3 38.5 38 38.5 43.5 45 38.5 28 37 8.5 3.5 12.5 7.5 54 48 18.5 13.5 15 10 20 15 12 7 48 47 48 52 51 48 46.5 46 8.5 6 12.5 10 66.5 58 18.5 15.5 15 12.5 20 17.5 12 9.5 57.5 59 57.5 62.5 63.5 58 59 57 D-A5/A6/A59W cannot be mounted to 40, 50.
*11 *11 *11 *11 *1 Set the inlet pressure to at least 0.05 MPa higher than the set pressure. *2 Options B, G, H, and M are not assembled and supplied loose at the time of shipment. *3 The assembly consists of a bracket and set nuts (applicable to the AR20(K)-D to AR40(K)-D).
CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD SG 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector. 12 SG Note 1) Do not orient diodes incorrectly
/32 9/32 1.43 1 1.71 3 5/8 2.36 6.44 5/8 1 15/16 2 1/4 1.81 M16x1.5 200 (2) 5/8 7/16-20 3/4 2.6 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3/8 1.26 1.06 11/32 11/32 1.84 1 1.71 3 5/8 2.40 6.44 7/8 1 15/16 2 1/4 1.81 M16x1.5 250 (2.5) 5/8 7/16-20 3/4 3.1 1 1/8 3/8 9/16 5/16-24 3 0 3/8 1.30 1.06 11/32 11/32 2.19 1 1.75 3 3/4 2.48 6.44 1 1/4 1 15/16 2 3/8 1.69 M16x1.5 325 (3.25) 1 3/4-16 1 1/8 3.9 1 1
*15 *15 *15 *15 *15 *15 *15 ZA*14 Digital pressure switch: With unit selection function *16 *16 *16 *16 *16 *16 *16 *16 *8 The only difference from the standard specifications is the adjusting spring for the regulator.
50 70 93 44.5 84 16 303 11 6.4 115 3.3 277 43 20 191 11 20 50 98 70 84 44.5 11 6.4 117.5 16 3.3 316 280 46 20 196 11 20 98 50 70 44.5 84 13 319 11 6.4 117.5 3.3 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
25 32 40 50 20 25 32 40 50 37 25.3 157 30 40 20 25 32 40 50 12 (14) 21 47.5 107 (115) 11 104 40 28.3 175 37 46 12 (14) 21 48 107 (115) 11 104 43 31.3 201 37 52 12 (14) 21 49 110 (118) 11 106 52.5 38.3 238 44 62 12 (15) 25 53 121 (130) 11 123 58.5 44.5 285 55 75 14 (16) 26 59 137 (149) 16 140 For long strokes Bracket mounting strokes Note) Dimensions inside ( ) are for long strokes.