Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: E3 (Output: PNP output / Electrical entry: Wiring bottom entry), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: CG (C + G), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: DG (D + G), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port: 03 (3/8), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: M [Round type pressure gauge (with color zone)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: Standard, Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port: 03 (3/8), Option: CG (C + G), Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993: *2 : : : 1, 2 3 1 2 3 4 -3No.EX-OMN0035CN-A / 1 1.5 *3) *3) 1 1 () -4No.EX-OMN0035CN-A () () () () -5No.EX-OMN0035CN-A /, , () * UL UL1310 Class2 0V -6No.EX-OMN0035CN-A * IP67 / *() ,, SI SI SI * IP67 M12M8 () -7No.EX-OMN0035CN-A CE , * 20-23 PLC PLC * -8No.EX-OMN0035CN-A , SI 1 SI 32 10 SI SI ON/OFF PNP
When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off.
When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
is mounted) 7.5 B B B B 102.9 111.4 118 100.4 91.9 A A A A B A B A B A B A Dimensions are the ones for SV1300--.
A B A B COM PWR A A A A B B B B Cable with M12 connectors EX500-ACP. 15 Connection of sensors with M8, M12 connectors (auto switch, pressure switch, etc. A B A B COM PWR A A A A B B B B Cable with M12 connectors EX500-ACP. 15 Connection of sensors with M8, M12 connectors (auto switch, pressure switch, etc.
Shield Brown Black Red Black Orange Black 12 13 7 6 9 8 3 Vcc GND A A B B B-4 A-4 B-5 A-5 B-6 A-6 LE-CP-3-B 360 LE-CP-5-B 590 LE-CP-8-B 1060 LE-CP-A-B 1320 LE-CP-B-B 1920 LE-CP-C-B 2620 Robotic cable Connector B terminal no.