No anchor bolt is included. 139 A HRSH090 Series Inverter Type * If the product is used at altitude of 1000 m or higher, refer to Operating Environment/ Storage Environment (page 151) Item 14 * For altitude of 1000 m or higher.
No.EX-OMW0014CN-A PROFINET SI / / EX245-SPN1A/2A/3A(SI ) EX245-DX1() EX245-DY1() EX245-LA1/LB1(IO-Link ) EX245-EA2-() 1. 11 1.1. 11 1.2. 12 2. 13 3. 14 3.1. 14 3.2. 16 4. 22 4.1. 22 4.2. 26 5. 30 5.1. 30 5.2. 34 6.SI 35 6.1. 35 6.2. 37 6.3. 39 6.4.LED 40 6.5. 43 7.EX245-DX1 46 7.1. 46 7.2. 47 7.3. 48 7.4. 48 7.5 LED 49 7.6. 50 8.EX245-DY1 51 8.1. 51 8.2. 52 8.3. 53 8.4. 53 8.5.LED
mA or less None Operating time 1.2 ms 1 ms or less Impact resistance 300 m/s2 1000 m/s2 Insulation resistance 50 M or more at 500 VDC (between lead wire and case) Withstand voltage 1500 VAC for 1 min.
Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) 133 (ms) Speed at a rated motor rotation of 3000rpm Accel/decel time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 * Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 47 - 5.6.4 Move distance Configuration and Operation
A 65 82 98 B2 53 64 76 B3 78 88 108 C1 14 20 22 C2 39 44 54 F 96 111 131 E1 1 1 1 E2 1 1 1 MY-J25 MY-J32 MY-J40 MYAJ25 MYAJ32 MYAJ40 63 73 93.5 61 72 88 30.5 36 44 40 46 55 73 84 104 14 14 19 6 6 8 Note) Floating brackets consist of a set of right and left bracket.
PneuAlpha Series Terminal Layout. 19 4.1 Installation Wiring Notes . 13 4.2 Wire Size and Specifications . 13 4.3 Power Supply. 14 4.4 Recommended Power Input Wiring Diagram. 14 4.5 AC Input Wiring. 15 4.5.1 AC Input Wiring Diagram. 15 4.6 Wiring Diagrams for the Sink/Source Terminals . 16 4.6.1 Source (+ Common) Input Wiring Diagram. 16 4.6.2 Sink ("-" Common) Input Wiring Diagram . 16 4.7
JXC-OMT0034CN (GW)(CC-Link) / LEC-GMJ2 1. . 4 2. . 6 2.1 . 6 2.2 . 6 2.3 . 7 2.4 () . 8 (1) . 8 (2). 8 (3)(LEC) . 8 (4). 8 (5) . 8 (6) . 9 (7) . 9 3. . 10 3.1 . 10 3.2 . 12 3.3 . 13 (1)(LECGMJ2) . 13 (2)DIN (LECGMJ2D) . 13 3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1 (STATION NO.,B RATE) . 15 4.2 (CN2SW) . 16 4.3 (LEC) . 17 5. . 19 5.1 CN4 . 19 5.2 CN3 . 19 5.3 CN1CONT . 19 5.4 CN2PC
120 53.5 28 40 242 36.5 30 6.8 6.6 M6 x 1 12 16 116.5 M8 x 1.25 14 M10 x 1.5 372 354 186 190 124 158 118 73 106 144 140 64 30.5 43 286 40.5 35 8.6 8.5 14 15 AA BB CC DD EE FF GG II JJ KK LL MM NN WW XX ZZ Model ML1C25 ML1C32 ML1C40 1/ 8 5 5 5 5 7 28 26 14 44 20 16 12.5 120 42 8 D1/ 8 6 5 6 5 8 36 28 18 54 36 18 12.5 140 48 8 1/ 4 30.5 6 5 6 5 8 47 17 62 30 22 16.5 170 51 10 -X 1113 ML1C
1000m/s2 Insulation resistance 50M or more at 500V DC (between lead wire and case) 1500V AC/min.
Startup . 10 3.1 Startup procedure. 10 3.2 Procedures for actuator operation . 11 3.3 Setup software (MR Configurator2TM ) . 12 3.3.1 Installation method . 12 3.3.2 Startup setup software (MR Configurator2TM) . 12 3.3.3 System settings . 13 3.3.4 Model selection. 13 3.3.5 Driver ON LINE check . 14 3.3.6 Help function . 14 4. Parameter setting . 15 4.1 Operation modePr.
VBA VE VY1 SW round head Phillips screws G M3 x 8 Panel PPA Gasket A AL Display protective cover Tighten screws by 1/4 to 1/2 turn after the heads are flush with the panel. 14-8-41
Move Speed Position Accel PushingF T riggerL V PushingSp Moving F Area1 Area2 In posn mm/s2 mm/s mm mm/s2 mm/s mm mm mm 0 Absolute 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 Absolute 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 Absolute 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 6.
Mount the switch in a locations where there is no vibration greater than 98 m/s2 or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
acceleration, whichever is smaller. 4.9 m/s2 Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Weight Note 3) 410 g 470 g 650 g 1,100 g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W2/3.
Do not drop, bump, or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 5. Do not allow short circuiting of loads.
(Convertible) Standard 0.2 to 1.0 Operating pressure range (MPa) For vacuum 100 kPa to 0.2 Pilot pressure (MPa) 0.2 to 1.0 (Equivalent to the operating pressure or more) Ambient and fluid temperature (C) 10 to 50 (No freezing) Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance (m/s2) Note) 300/50 Note) Impact resistance: No malfunction to axis and right
Reset the accumulated time here. 14 Anti-freezing function Circulating fluid is protected from freezing during winter or at night. Set beforehand if there is a risk of freezing. i [ ] lamp Equipped with a timer for start and stop.
DWith M3 port 2023 mm x 15 mm x 10 mm 9.5 g Variations Page Page Page 12-8-14 12-8-14 12-8-22 MHC2-6n MHCA2-6n MHCM2-7S Model Cylinder bore 6 6 7 Double acting Action Single acting (Normally open) Single acting (Normally open) 30n to s10n Opening/Closing angle (Both sides) 20 to s7 0.038 Nm (Double acting) Holding moment (at 0.5 MPa) 0.017 Nm 0.024 Nm (Single acting) Repeat ability Maximum
DWith M3 port 2023 mm x 15 mm x 10 mm 9.5 g Variations Page Page Page 12-8-14 12-8-14 12-8-22 MHC2-6n MHCA2-6n MHCM2-7S Model Cylinder bore 6 6 7 Double acting Action Single acting (Normally open) Single acting (Normally open) 30n to s10n Opening/Closing angle (Both sides) 20 to s7 0.038 Nm (Double acting) Holding moment (at 0.5 MPa) 0.017 Nm 0.024 Nm (Single acting) Repeat ability Maximum
Refer to the accessories on page 4-7-14. 4-7-9 10 Series VT317 Standard Specifications Type of actuation Direct operated type 2 position single solenoid Air Fluid Operating pressure range 0 to 0.9 MPa 10 to 50C (No freezing. Refer to page 4-18-4.)