Heat generation amount by users equipment Q : Unknown [W] ([J/s]) Circulating fluid : Tap water* Example of current measurement units (Reference) Circulating fluid mass flow rate qm : (= x qv 60) [kg/s] Circulating fluid density : 1 [kg/L] Circulating fluid (volume) flow rate qv : 70 [L/min] Circulating fluid specific heat C : 4.186 x 103 [J/(kgK)] Circulating fluid outlet temperature
Application example Transferring Cutting 1 Series CY3B/CY3R Model Selection Method Operating conditions E: Kinetic energy of load (J) (W + WB) V 2 E = x ( ) 2 1000 Es: Allowable kinetic energy for intermediate stop using an air pressure circuit (J) Fn: Allowable driving force (N) MD: Maximum allowable moment (Nm) when a connection bracket, etc. is carried directly Ps: Operating pressure limit
Application example Transferring Cutting 1 Series CY3B/CY3R Model Selection Method Operating conditions E: Kinetic energy of load (J) (W + WB) V 2 E = x ( ) 2 1000 Es: Allowable kinetic energy for intermediate stop using an air pressure circuit (J) Fn: Allowable driving force (N) MD: Maximum allowable moment (Nm) when a connection bracket, etc. is carried directly Ps: Operating pressure
Heat generation amount by users equipment Q : Unknown [W] ([J/s]) Circulating uid : Tap water Example of conventional measurement units (Reference) Circulating uid mass ow rate qm : (= x qv 60) [kg/s] Circulating uid density : 1 [kg/L] Circulating uid (volume) ow rate qv : 35 [L/min] Circulating uid specic heat C : 4.186 x 103 [J/(kgK)] Circulating uid outlet temperature T1 : 293 [K] (
Bore 6 10 16 6.4 8.1 9.2 5.5 7 8 2.4 3.2 4 M3 X 0.5 NTJ-006A M4 X 0.7 NTJ-010A Clevis pins and set rings are attached.
M3 x 0.5 x 3L M8 x 1.25 x 8L (Bolt holder) (Hexagon socket head set screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 16 32 2-M3 x 0.5 through 6.5 counter bore depth 5 (Same on the opposite side) 3.4 through 3 3 45 45 5.5 M2.5 x 0.45 x 6L (Cap screw) M3 x 0.5 x 12.5L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2-M3 x 0.5 through Steel ball Plug 2-M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no
Lock ring Lock ring Retraction locking Extension locking 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15l or more on the market) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (rear side) to unlock. 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15l or more on the market
7 7.8 17 22.5 24 14.5 0.8 5 3.2 M3x0.5 KJH23-M3 7 18 15.5 14.5 0.9 1.6 3.2 M5x0.8 KJW23-M5 7 7.8 17 25 26 14.5 2.6/2.2 6.3 3.2 M5x0.8 KJH23-M5 7 18.5 15.5 14.5 3/2.5 2.1 3.2 R(PT)1/8 KJW23-01S 10 7.8 17 25 25 14.5 2.6/2.2 10.4 3.2 R(PT)1/8 KJH23-01S 10 16.5 12.5 14.5 3/2.5 5 4 M3x0.5 KJW04-M3 7 8.9 17.5 23 25 14.5 0.8 5 4 M3x0.5 KJH04-M3 8 18 15.5 14.5 0.9 1.9 4 M5x0.8 KJW04-M5 7 8.9 17.5
Max. air flow rate (m3/min (ANR)) JIS Symbol P . 14-20-55 Inlet pressure (MPa) Caution Be sure to read before handling.
Nm N M1 M M3 W W2 W W4 ML2B25 10.0 1.2 3.0 200.0 58.0 65.0 100.0 ML2B32 20.0 2.4 6.0 300.0 80.0 96.0 150.0 ML2B40 40.0 4.8 12.0 500.0 106.0 140.0 250.0 ML2B25 ML2B32 ML2B40 J 0.43 0.68 1.21 18 ML2B/M1 ML2B/W1 ML2B/W1 0 0 0 Nm 0 0 0 N N 0 m/s m/s m/s ML2B/M2 ML2B/W2 ML2B/W2 N m N N m/s ML2B/M3 m/s m/s 20 ML2B/W3 ML2B/W3 10 Nm 5 3 2 1 N N m/s m/s m/s ML2B/W4 500 N 00 N
Compressed air 1.0MPa Fluid Max. operating pressure Min. operating pressure (1) 0.05MPa 1.5MPa Proof pressure Ambient and fluid temperature Filtration rating 5 to 60C 0.01m(95% particle size collection) Oil mist removal rate Max.0.1mg/m3 (ANR) (2) (At saturation of element oil, less than 0.01mg/m3(ANR){0.008ppm}) 2 years or when pressure drop reaches 0.1MPa Element life Note 1) With N.O.auto
Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).
Cool from 30C (303 K) to 20C (293 K). : Tap water Density g: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath * Refer to the information shown below for the typical physical property values by circulating fluid.
Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).
D Side U Side C Switch specifications w How to Order Valves Nil J Without switch With switch Enter the symbols for the required specifications in the blanks below.
B' B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Drain cock Drain guide R, NPT, G Operating Pressure: 0.5 (MPa) Operating pressure: 0.5 (MPa) Mounting bracket Port size Model E M3 x 0.5 Depth 8 Drain piping D C B A F G H J K B' 3 8 AMC310 75 140.5 138.5 150.5
(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without unit switching function.) Refer to the specifications of display unit for the flow rate value per pulse.
screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 32 16 2 x M3 x 0.5 through 6.5 counterbore depth 5 (Same on the opposite side) 3.4 through 3 3 45 5.5 45 M2.5 x 0.45 x 6 L (Hexagon socket head cap screw) M3 x 0.5 x 12.5 L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2 x M3 x 0.5 through Steel ball Plug 2 x M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no.