Note 2) When symbols C or D are specified, an auto drain with a part number shown on page 18 is mounted.
It is already built-in to the rectifier circuit. 50 60 110 VAC Hz [115 VAC Hz] 3 50 60 50 60 50 60 4 220 VAC Hz [230 VAC Hz] Electrical entry D With connector DIN terminal DC specifications of type D and DO is only available with 12 and 24 VDC.
A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.
M1 Weight (g) ASV120F-M3-04 ASV220F-M5-04 ASV220F-M5-06 Model 5 8 9 M3 x 0.5 M5 x 0.8 M5 x 0.8 5.5 8 8 9.3 9.3 11.6 7.2 9.6 9.6 21.4 22.8 23.6 25 27.6 28.4 9.8 11.1 11.1 28.6 31.4 31.4 26.1 28.6 28.6 25.8 27.7 27.7 23.3 24.9 24.9 12.7 12.7 13.5 4 4 6 Reference dimensions of M thread after installation. Inch Size Applicable tubing O.D. d T H D1 D2 L1 L2 L3 L4 A Max. Min. Max. Min.
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15
Metric sizes Type 4 6 8 10 12 04 06 08 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 x 0.8 1/8 1/4 3/8 1/2 M5 01 02 03 04 With One-touch fitting Clean specification Metal part material Q G Brass (electoless nickel plated) Stainless steel (SUS304) Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06
Fig.1-3 shows the location of the communication port. 14 1 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 Fig.1-3 Communication port HRS400-A-46 1.3 Communication port 1-5 DOC1003626 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.
M5 01 02 03 04 06 10 D AF30 to 60 Flow direction: Right to left AF10 to 60 F Note 2) Note 3) Bracket is not assembled and is supplied loose at the time of shipment. Note 4) Applicable tube O.D for auto drain connection should be 3/8" in case NPT thread port is chosen.
Fluid Table (1) Rated Voltage-Electrical Entry-Electrical Option Standard specifications Option (1) Made to Order (2) Water (standard) Turbine oil High temperature water (D, E) Air X500B Vacuum (up to 1.3 x 10 2 Pa) X500B For pure water X500 G C Class B D, T Class H G, C T S Note) S L, Z L, Z S Note) Surge voltage suppressor is attached in the middle of lead wire.
AS2002F-04 When connecting 4 pcs. and mounting L-brackets on both sides Speed controller AS2002F-04 4 pcs. L-bracket AS-20L 2 pcs.
Port size AS-D U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 AS-T ASP Needle Valve/Flow Rate Characteristics ASN AS2201FSl-U02, AS2211FSl-U02 AS2201FSl-U01, AS2211FSl-U01 300 600 AQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 500 ASV 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 03, 04 06, 07 200 400 AK 01, 23 300 VCHC 03, 04 100 200 ASR ASQ 01, 23
AS2001F-04-3-X12 Ex.) AS2001F-04-3-X21 Note) Not particle-free Throttle Valve (Without Check Valve) X214 Ex.)
M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3
Applicable tubing O.D. d Weight (g) D1 39.2 M1 L3 12.9 M2 M1 12.9 L2 14.3 L4 12.9 L1 5.2 D2 39.2 L3 23.5 Weight (g) D1 10.0 L2 13.7 L1 5.2 Model Tubing O.D. d AQ240F-04-00 Model Tubing O.D. d AQ240F-04-04 6 4 9.3 5 4 9.3 AQ240F-06-00 AQ240F-06-06 13.7 13.7 15.4 6.2 13.7 26.7 40.7 8 10.0 14.7 6 11.6 6 6 11.6 6.2 40.7 AQ340F-06-00 AQ340F-06-06 13.7 19.5 13.7 13.7 6.3 44.8 31.7 13 19.6 11.8
X Port size) Sysytem Figure Silencer System Solenoid valve Speed controller 4 X M5 6 X M5 6 X 1/8 6 X M5 AS1301F-M5-04 A SYJ3000 M5 X 0.8 (S = 1.8mm2) AS1301F-M5-06 B q AN120-M5 (S=5mm2) AS2301F-01-06 C 6 X M5 AS2001F-06 D w 1.2-9 Series SYJ3000 How to Order Bracket Light and surge voltage suppressor Configuration S Z R U Without light and surge suppressor With surge suppressor With light
Precautions FH150-02 to 04 q Mounting Confirm IN and OUT before mounting.
After washing the element, make sure the base seal is properly mounted. 500 A Vertical Suction Filter FHIA Series Dimensions Differential pressure indicator 16 B (34) F OUT Removal dimension K H F OUT D E C H Differential pressure indication switch FH FH 62 HOW (65) F IN 4 x I OUT A J G (mm) A B C D E F G H I J K Model Weight (kg) FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA
64.7 25.4 28.6 AS421FE-04-12SK 22 48.9 34.6 12 20.9 105 Reference dimensions of R thread after installation.
Product Profile: ISO Standard Solenoid Valve: Size 1, 2 Rubber Seal Series VP7-6/7-8 Solenoid valve conforming to ISO standard Size (1)/VP7-6 Size (2)/VP7-8 (Rubber seal) Single solenoid (FG-S) Double solenoid (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) 2 position 3 position Closed center (FHG-D) Exhaust center (FJG-D) Double pilot check (FPG-D) Pressure center (FLG-D) Courtesy
* C D H* Description None Mounting Bracket Float Auto Drain (N.C.)