SMC Corporation of America
Elite Part Number Search
Search Results "AV4000-04-3DB-R-A"

This product cannot be used as a check regulator by installing it between solenoid valve and actuator. 3. Port with a pressure gauge or a plug can be used as an OUT port.

Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.

(Full span) 0.05 to 0.7 MPa Rc AF Mounting Linearity (3) AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Signal pressure (3) IR 1 8 Signal port PA (3) 02 03 02 04 04 06 10 10 12 14 20 01 Port P A R M5 01 M5 01 01 02 VEX Port size Rc (4) (4) 1 2 1 1 1 4 1 1 8 1

11.7 12.7 17 31.1 27.1 32.1 36.1 14.2 14.3 R 1/8 12 13.5 18.5 16 17 18.5 21.0 19 32 18.2 18.5 R 1/4 17 35.4 29.4 34.4 40.4 34 36 Reference dimensions for M5 and R threads after installation. 20.0 Inch Size A L4 Model Weight (g) M1 d D2 L3 L2 D1 L1 H T Max.

Hs D-A44 A A 49.5 Auto switch 376 Auto Switch Mounting CH2E/CH2F/CH2H Series Auto Switch Proper Mounting Positions CHQ D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA Note2) D-A9/A9V Bore size (mm) D-G39/K39 D-A5/A6 D-B5/B64 D-A3/A44 D-F5NT D-A59W D-B59W CHK CHN A A A A A A A A A A A 32 25 21.5 26.5 17 15 19 15.5 18.5 CHM 40 26 22.5

When using seal tape, leave one thread exposed when wrapping fitting or pipe. 0.1 i'--... 01 5 O~ o 0.2 0.3 0.4 0.5 0.6 0.7 08 0.9 1 00 1000 2000 Flow ra te / mi n IANR) Inlet pressure MPa AR3001-03 AR3001-03 0.6 ~ 0.5 ---'" " Jp J 0.25 '" I r~r " ::;; l' 0.2 ~ --P l' a. r< & "" & l' ::> 0.4 ~ ~ ~ 0.3 ~ -... a. ID '$'2 1-?/"(9 . "OS .

A A A A A A A 2-C6 P (SUP port) 24.5 (11) 13.5 B B B B B B B B R R 7 P = 11 19.2 2-C6 R (EXH port) (7.5) 2n-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 thread The broken lines indicate the DIN rail mounting style [-D] and the top entry connection [-PU].

A B C A B A B A B A B 15A 20A 25A Note 1) For each piping diameter for each body size, the second and later numbers or symbols indicate reducing.

6 RE A B REC CX CY MQQ M RHC #2 !1 w t #6 #0 @2 u o r !3 !2 #5 !7 #1 #3 #4 e !8 @3 MK(2) @7 @8 @5 @6 RS Q G RS H A RZQ MI W S CEP1 N@4 @9 CE1 Component Parts CE2 No. Description Body No. Description Note Hard anodized Material Aluminum alloy Material Note Hard anodized Aluminum alloy Plate A q !

Description Material Note Note RS Q G Body Hard anodized Aluminum alloy Special resin Wear ring A @1 q Cylinder tube Stainless steel Special resin Wear ring B @2 w RS H A Shaft Stainless steel NBR Piston seal @3 e Piston side yoke Zinc chromated Rolled steel plate NBR Scraper @4 r RZQ Zinc chromated Rolled steel plate External slider side yoke NBR Cushion seal @5 t Magnet A Rare earth

VQ VQ4 Note) R block valve is mounted in the blocking position when ordering an individual EXH spacer incorporated with a manifold. When separately ordering an individual EXH spacer, separately order a R block valve. VQZ P R PR 1 2 0 1 P R PR Block valve VQD VQ 4 --Valve No.

VX3 Threaded M5 x 0.8 VXA Fluid temperature (C) 0 to 100 Ambient temperature (C) 0 to 60 VN Weight (kg) 0.09 0.15 0.36 0.17 LVC Construction LVA Standard type N.C. type N.O. type Double acting type LVH LVD LVQ PB PB PB q q q LQ PA PA PA e e e LVN TI/ TIL A B A B A B A B A B PA r w PAX PB With flow rate adjustment t PB PA Description Material Parts list No.

Operate the piston within a range such that collision damage will not occur at the end of the stroke. When a cylinder is used in a clamping mechanism, there is a danger of work pieces dropping if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage, etc.

0 o @0 i A A MX MTS MY CY !4 !3 y e !2 q r t o !6 @0 !4 !1 q !6 i t y e !5 r u !

R R R P A A A A A 63.6 60 P 42 B B B B B 6-Rc(PT)1/4 (P, R port) Manual override L2 10 Depress and turn to operate and lock override.

(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.

Port size ASV Model M3 x 0.5 ASV120F-M3 0.3 0.3 AK M5 x 0.8 ASV220F-M5 1.3 1.3 R 1/8 ASV310F-01 8 7 ASS R 1/4 ASV310F-02 8 7 R 1/8 ASV410F-01 14 13.5 ASR R 1/4 ASV410F-02 14 13.5 R 3/8 ASV410F-03 14 13.5 ASF R 1/4 ASV510F-02 27 23 R 3/8 ASV510F-03 29 27 R 1/2 ASV510F-04 29 27 10-32 UNF ASV220F-U10/32 1.3 1.3 NPT 1/8 ASV310F-N01 8 7 NPT 1/4 ASV310F-N02 8 7 NPT 1/8 ASV410F-N01 14 13.5 NPT 1

) 0x1F88 (8072) 1 R Rated range lower limit N S16 2 R Rated range upper limit N S16 3 R Measurable range lower limit N S16 0x1F9A (8090) 0x1F9B (8091) 0x1F9C (8092) 0x1F9D (8093) 4 R Measurable range upper limit N S16 5 R Settable range lower limit N S16 6 R Settable range upper limit N S16 1: "R" means Read and "W" means Write.

Note 2) O-ring e is included with manifold valve r. 17-2-18 13 Series VCA Direct Operated 2 Port Solenoid Valve For Air Manifold Option Parts Blanking plate assembly (VCA20) VVCA20 4A This is used when a blanking plate is mounted on a manifold as preparation for a planned valve installation.