Note Note 1) Value when cooling water inlet temperature is 32C and with rated load Note 2) Calculated at 1 RT = 3,300 kcal/h IDF-S0302 230 VAC IDU3E to 37E-23 IDU55E, 75E-23 IDF-S0198 (mm) Dimensions A B C D E Model IDF120D IDF150D 180 250 160 90 225 IDF190D IDF240D 180 250 160 48 273 IDF120D to 240D B Cooling water outlet A Condensation pressure gauge Cooling water inlet E D C Drain plug
Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S
With barb fitting With drain guide Metal bowl Metal bowl with level gauge Model B B 107 160 214 251 255 B B AC10A AC20A AC30A AC40A 208 246 249 234 272 275 209 247 250 AC40A-06 6 F.R.L.
Construction Figure-4 125 to 160 Table. 13 Parts list No.
(ASME B40.1 Grade B or better) psig/bar 4) (No code) Accuracy Cleanliness No oil ASME B40.1 level IV No oil Brass Polycarbonate Brass Phosphor bronze B Case Window Socket Bourdon tube Material MPa MPA 1.14 (29) 2.28 (58) 2.1 (53.5) 2.12 (54) NPT 1/4 0.42 (10.5) inch (mm) 3) Part number of pressure gauge itself.
(c) (a) (b) (c) (b) (c) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) Note 1) The above (a), (b), (c) indicate heater mounting positions.
Description No. 2 Common IN Individual IN Common IN Individual IN Bonnet Polyacetal Regulator NARM2500-A-N02 NARM2500-B-N02 NARM3000-A-N03 NARM3000-B-N03 9 Regulator 1 Component Parts 10 End plate R 1 No.
A B A B A B A B A 32 8 (6) 7 (5) 8.5 (6.5) 14.5 (11.5) 9 (7) 8 (6) 7 (5) 6 (4) 6 (5) 12 (9) 40 10 (11) 12 (9) 7.5 (5.5) 12.5 (9.5) 15 (12) 13 (10) 13 (10) 11 (8) 5 (3) 11 (7) Aim at this number ( ) For air cushion type Auto Switch Mounting Height (mm) D-F7/J79 D-F7W D-J79W D-F7BAL D-F79F D-C7/C80 D-H7 D-H7W D-H7BAL D-H7NF D-A7 D-A80 D-A7H D-A80H D-C73C D-C80C D-A73C D-A80C D-H7C D-A79W D-J79C
A B A 32 6 7 7 8 40 11 13 12 14 Aim at this number.
Note) B Note) B Note) B Note) B Note) AW10 AW20(K) AW30(K) AW40(K) AW40(K)-06 AW60(K) 125 177 242 278 282 448 209 247 251 417 164 208 246 249 416 107 160 214 252 255 422 234 272 275 442 AV AF800 AF900 Note) The total length of B dimension is the length when the filter regulator knob is unlocked. 373 Filter Regulator AW20 to AW60 Made to Order Specifications: Please contact SMC for detailed
Valve side exhaust 29 Series XLS High Vacuum Angle Valve Dimensions (mm) 1in=25.4mm XLS/Without control power supply Grommet (G) D Conduit (C) J K 27010 E D G B C G(PF)1/2 Terminal (T) J K2 J H 29010 L 25 33 B C G(PF)1/2 DIN terminal (D) J K L C B F A 29.5 39 B C G(PF)1/2 6 to 9 22 A (mm) A B 104 L 48 62 C D F G H J E K 41 60 95 43 Model XLS-16G XLS-16C XLS-16D XLS-16T XLS-25G XLS-
(Including bracket, set screw) Mounting bracket (b) Cylinder series Applicable bore size (mm) 32 40 50 63 80 100 125 140 160 180 200 1. Fix the mounting bracket (A) on the auto switch with the set screw. 2. Fit the concave part of mounting bracket into tie-rod and set the auto switch at the mounting position. 3.
7 35 114 +0.030 0 6H9 ( ) depth 7 (158) 63.5 Motor cable (6) 73 Encoder Z phase detecting position Note 2) Motor option: B/With lock L A (Table traveling distance) Note 1) 186 (B: With lock/226) 39 (64) Encoder cable (7) Stroke (66) 2o1 (4) 70 58 47 Lock cable (4.5) 6.7 35 Motor cable (6) 0 8H9 ( ) depth 6 B 30 +0.036 +0.036 0 8H9 ( ) depth 6 n x 6.8 13 140 79 200 C x 200 (=D) E 25 Note
In this case, the rigidity of the machinery should also be examined. 9 - 7) How to order 25A D B 125 100 D-M9* C S2 Auto-switch Stroke Bore size Mounting bracket Built-in magnet Secondary battery production facility Air Cylinder Built-in magnet Bore size D Built-in magnet 125 125mm Nil Without magnet 140 140mm 160 160mm Mounting B L *Refer to Maximum stroke table(P5 Table 1) F G Auto-switch
Seat material Hastelloy C-22 H No gauge port Material PCTFE (Standard) Vespel 3) PTFE4) 5) Code No code No code VS TF No pressure gauge (Connections: 1/4 inch face seal male) 0 Surface finish Surface finish Ra max 15 in. (0.4 m) Standard 10 in. (0.25 m) 7 in. (0.18 m) 5 in. (0.13 m) Code Ports V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160
so that an even number will be allocated. a) I/O mapping Auto mapping/fixed mapping Fixed mapping Available 16 to 1280 points (2 to 160 bytes) Increase and decrease by 128 points. b) System input 1280 points/ 160 byte Available This is not settable when the I/O mapping is set to "Auto". size 16 to 1280 points (2 to 160 bytes) Increase and decrease by 128 points.
Refer to pages starting with 181 for mounting. 30 95 B 100 95 8(4)-6.2 (160) () () 110 95 20 95 A (140) () () A B Stroke Model LG1H202PA-100-F LG1H202PA-200-F LG1H202PA-300-F LG1H202PA-400-F 100 200 300 400 50 150 250 70 170 270 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)
B) Under the above conditions, adjust shim so that the space between the workpiece and the clamping block is about 0 mm. Theoretically there is no clamping force for holding a workpiece under this condition. C) In order to generate clamping force from the state described in step B, insert additional shim.
Applicable cylinder MY3A16, MY3B16 MY3A25, MY3B25 MY3A40, MY3B40 MY3A63, MY3B63 A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 Data 091 130 182 Guide for Using Side Support For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.