SMC Corporation of America
Elite Part Number Search
Search Results "CDJP2F10-30D-B-A93S"

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: B (Without Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: B (Without Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PIN, DBL ACT, ACTUATOR, CJP/CJP2 ROUND BODY CYLINDER, EE, 10MM CJP/CJP2 DBL-ACT AUTO-SW, .11023 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PIN, DBL ACT, ACTUATOR, CJP/CJP2 ROUND BODY CYLINDER, EE, 10MM CJP/CJP2 DBL-ACT AUTO-SW, .10802 lb

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without