SMC Corporation of America
Elite Part Number Search
Search Results "CDM2YL20-125Z-A93"

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: A93, Lead

Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 16mm, Stroke: 125mm, Head Cover Port Location: Perpendicular to Axis, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)

Magnet: D (Built-in), Series: J2, Mounting: E (Double-side Bossed), Bore Size: 16mm, Stroke: 125mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Bearing Type: Slide Bearing, Bore Size: 63mm, Port Thread: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 125mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: w/Coil Scrapper, Suffix: -

Bearing Style: Slide Bearing, Bore Size: 40mm, Port Type: Rc, Stroke: 125mm, Z: Z, Locking Direction: Retraction Stroke Lock, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bearing Style: Slide Bearing, Bore Size: 80mm, Port Type: Rc, Stroke: 125mm, Z: Z, Locking Direction: Retraction Stroke Lock, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Bearing Style: Ball Bush Bearing, Bore Size: 50mm, Port Type: Rc, Stroke: 125mm, Z: Z, Locking Direction: Retraction Stroke Lock, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: A93, Lead

Magnet: Built-in Magnet, Mounting: Axial Foot, Bore Size: 20mm, Port Thread: Rc, Stroke A: 125mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or

Magnet: Built-in Magnet, Mounting: Axial Foot, Bore Size: 20mm, Port Thread: Rc, Stroke A: 125mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2: 1 m type lead wire is only applicable to D-A93.

Note 4) ( ) in column W is the dimensions of D-A93.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

D-A93 45 to less than 50 stroke D-M9 D-M9W 15 to less than 20 stroke 45 to less than 55 stroke Note 2) D-A3A/A44A/G39A/K39A cannot be mounted on the centralized piping type Series CDM2P.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Auto Switch Internal Circuit D-A90 Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A93 D-A96 Auto switch part no. 0.5 6 6 8 41 Lead wire length (m) 3 30 30 D-A93 LED diode Brown OUT (+) Brown Contact protection box Resistor Dimensions Unit: mm Reed switch Zener diode CD-P11 D-A90/D-A93/D-A96 CD-P12 OUT () Blue Blue D-A96 DC (+) Brown Indicator