Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. Auto Switch Mounting Band Part No.
The below table shows the applicable maximum stroke (in cm units), found by calculation assuming the case where the force generated by the cylinder itself acts as buckling force on the piston rod, or piston rod and cylinder tube.
. %100 1 ~ Operation Double acting single rod Media Air " Proof pressure 217 psi {15.3kgf/cm.2} Min. operating pressure . 7 psi {O.
~} {-1 10.2kgf/cm"'1 I Max operating plessure 200kPa (2.04kgjlcm~ 200kPa {2.04kgl:cmZ } l MPa{10 .2k9.!!
energy (J) 0.811 0.082 0.54 0.16 0.112 0.6 0.12 0.398 Allowable radial load (N) Free-Mounting Type CRBU2 CRB2 588 245 490 390 245 588 390 490 Shaft load Allowable thrust load (N) 539 196 490 340 196 539 340 490 Ball bearing Bearing type Side ports or axial ports Port position Side ports Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Size Axial ports Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Basic, Foot Mounting Volume (cm
Do not to obstruct the aftercooler's vent inlet and outlet, and install the equipment more than 20 cm away from the walls or other equipment. 2. Install the aftercooler in a location that facilitates maintenance and inspection. 3. Install the aftercooler in a location with minimal vibrations. 4.
Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. Auto Switch Mounting Band Part No.
General Withstand voltage 500 VAC for 1 minute between external terminals and metallic parts Insulation resistance 10 M or more (500 VDC between external terminals and metallic parts) Standards CE marking, RoHS compliant Weight 300 g Communication standard ISO/IEC14443B (Type-B) Frequency 13.56 MHz NFC communication*3 Communication speed 20 to 100 kHz (I2C) Communication distance Up to 1 cm
Deionized water (with an electric conductivity of approximately 1 S/cm) can be used, but may lose its electric conductivity. Also, if a facility supplying deionized water is used, the thermocon may be damaged by static electricity. When installing the product into a rack, it should be designed that the product weight is held with the bottom surface of the product.
Deionized water (pure water) [with an electric conductivity of approx. 1 S/cm] can be used, but may lose its electric conductivity. Also, if a facility supplying deionized water (pure water) is used, the thermo-con may be damaged by static electricity. Operating Environment/Storage Environment Warning 1. Keep within the specified ambient temperature and humidity range.
Provide about 30 cm of space above and below the D.P. Lube or the D.P. Lube Unit to facilitate their maintenance and inspection. 2. When the line is stopped, do not adjust or set the differenital pressure, as it could cause the differential adjustment valve to break. 3.
PC I/O Configurator OS (Windows) PC/SC driver Establish communication by adjusting the position so that the height from the center of the NFCR/W antenna to the "O" on the wireless unit is 1 cm or less. NFC reader/writer Wireless Base unit Wireless Remote unit Memory area where power supply is unnecessary. Memory area where power supply is necessary.
PC I/O Configurator OS (Windows) PC/SC driver Establish communication by adjusting the position so that the height from the center of the NFCR/W antenna to the "O" on the wireless unit is 1 cm or less. NFC reader/writer Wireless master unit Wireless slave unit Memory area where power supply is unnecessary. Memory area where power supply is necessary.
Place the NFC reader/writer within 1 cm of the centre of the wireless symbol on the wireless unit to display the wireless master/slave information and change the parameter setting. Here, basic functions of the I/O configurator for NFC are given. (1) (2) (3) (4) (5) (6) -11No.EX-OMV0017 Basic characteristics No.
PC I/O Configurator OS (Windows) PC/SC driver Establish communication by adjusting the position so that the height from the center of the NFCR/W antenna to the "O" on the wireless unit is 1 cm or less. NFC reader/writer Wireless master unit Wireless slave unit Memory area where power supply is unnecessary. Memory area where power supply is necessary.
IN OUT [cm] -66No.PF-OMP0001CN-F PFMB7501/7102/7202 2x A B D E F H K L N PFMB7501/7102 70 30 43.7 37.2 15 14 26 18 13.6 PFMB7202 90 35 49.2 42.7 17.5 24 31 28 16.8 S T U V W PFMB7501/7102 24 22 32 40 50 PFMB7202 30 30 42 48 58 -67No.PF-OMP0001CN-F (ZS-33-D) (ZS-33-F) -68No.PF-OMP0001CN-F Revision history A B C D E F [September 2016] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021
The straight piping length shall be 8 cm or longer. Otherwise, if a straight section of piping is not installed, the accuracy varies by approximately 2%F.S. Avoid sudden changes in the piping size on the IN side of the product. Do not release the OUT side piping port of the product directly to the atmosphere without the piping connected.
Stainless (I include heat exchanger brazing), Aluminum oxide ceramic, SiC, Carbon, PP, PE, POM, FKM, EPDM, PVC (No. copper used) Circulating fluid wetted materials Servieable conductivity: 0.22S/cm or more. (Resistivity: 4.5Mcm or less.) This option doesnt include a function to maintain high resistivity/conductivity. You need ion exchange resin filter (DI filter) for the purpose.
Stainless (I include heat exchanger brazing), Aluminum oxide ceramic, SiC, Carbon, PP, PE, POM, FKM, EPDM, PVC (No. copper used) Circulating fluid wetted materials Servieable conductivity: 0.22S/cm or more. (Resistivity: 4.5Mcm or less.) This option doesnt include a function to maintain high resistivity/conductivity. You need ion exchange resin filter (DI filter) for the purpose.