MGC series 20 to 50 MGC Series (mm) C port SZ + Stroke B Cushion valve (Width across flats WH) Front mounting flange Bore size (mm) GC GD SA SB W 1 W 2 A, B port A port W 2 W 1 A 20 25 32 40 50 30 30 21 9 50 87 30 30 C port D port 21 9 50 87 B port W 2 W 1 10 A' 25 30 23 9 52 91 20 20 24 8 59 99 Cushion valve (Width across flats WH) D port ZZ + Stroke A + Stroke B SB + Stroke B SA + Stroke
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) B 15 16 A 12 13 B 19 20 A 11 12 B 18 19 A 8 9 SMC D-A90 20 25 SMC D-A90 A Approx.
to 50 M N Bracket (See table below.) 4-O T Q 2-P AH AG B S W K U L AA AL AB A I J AI AJ 4-AK hole V AP R Y + Stroke Z + Stroke X AG For 4-AO AN AI Cutout window AM Mounting dimensions For standard strokes (mm) Bore size (mm) Stroke range (mm) O N M L K J I B AP AO AN AM AH AG AB AA AL AK AJ AI A 20 25 32 40 50 75, 100, 125, 150, 200 M6 x 1 depth 9 45 25 80 60 55 30 108 25 M6 115 65 125 112
W/o auto switch B L L1 With auto switch Bore (mm) 5st 10 A 20 20 20 20 5st 10 5st 10 5st 10 32 48 58 12 33.5 58 68 17 38.5 40 64.5 12 33.5 64.5 74.5 17 38.5 45.5 50 67.5 77.5 18 43.5 87.5 97.5 28 53.5 Rod end male thread Double clevis (mm) A Without auto switch B CL A B CL With auto switch Bore (mm) Double clevis/CQ2D, CDQ2D 5st 10 20 20 20 20 20 20 5st 10 5st 10 5st
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or return from an intermediate stop using an external stopper, etc. RE A B Reference values for non-rotating accuracy and maximum allowable moment at stroke end are indicated below.
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or return from an intermediate stop using an external stopper, etc. RE A B Reference values for non-rotating accuracy and maximum allowable moment at stroke end are indicated below.
(Red Green Red) D-B59W D-A79W D-A59W D-H7NW/H7PW/H7BW D-G59W/G5PW/K59W D-F79W/F7PW/J79W D-F7NWV/F7BWV D-F59W/F5PW/J59W D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV D-Y7NW/Y7PW/Y7BW Band Grommet 10-20-23 Solid state switch Reed switch Rail Grommet 10-20-24 Tie-rod Grommet 10-20-25 2-color indication 10-20-42 Band Grommet RE A B 10-20-43 10-20-44 Rail Grommet REC 10-20-45 Tie-rod Grommet 10-20-46
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
D-A9, D-A9V D-M9, D-F9W D-M9V, D-F9WV Bore size (mm) B W A W W B B A A 6 10 16 20 25 32 9.5 1.5 17.5 0.5 5.5 9.5 13.5 17.5 3.5(1) 13.5 5.5 16.5 3.5 9.5 13.5 12.5 16.5 7.5(5) 15.5 7.5 20 5.5 11.5 15.5 16 20 9.5(7) 19 11 24 9 15 19 20 24 13(10.5) 20 12.5 26.5 10.5 16 20 22.5 26.5 14.5(12) 22.5 14.5 27.5 12.5 18.5 22.5 23.5 27.5 16.5(14) Note 1) Figures in the table above are used as a reference
@ ZP3-T(04/06/08)B;(JB/K)15-@ ZP3-T(04/06/08)UM(JB/K)20-@ ZP3-T(04/06/08)B;(JB/K)20-@ ZP3B-T2A(J/K)3-B5 Note 1) ; in the table indicates the pad material.
Lead 20: LEYG32A 30 30 20 20 0 0 0 200 600 1000 1400 1200 Speed [mm/s] 0 200 600 1000 1400 Speed [mm/s] 866 A Model Selection LEYG Series Motorless Type * These graphs show an example of when the standard motor is mounted.
Note) The minimum bending radius of the D-sub connector cable is 20 mm. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 COM 572 VQC Series Plug-in Unit Base Mounted F IP40 compliant VQC1000/2000 Series Kit (D-sub connector) (L4) (L3) L2 L1 VV5QC11 (5.25) 63.5 51 35 28 1.5 P = 10.5 Manual override 13 (12) Indicator light 1.5 SV (5.5) SYJ B A A B A B A B A B A B A 2 93.5
Electric entry direction: Inward Electric entry direction: Outward A B A B D-Z7, D-Z8, D-Y7W D-Y5, D-Y7 D-Y6, D-Y7V D-Y7WV D-Y7BAL Bore size (mm) A B B B 3.8 11.3 9.8 (8.3) 13.8 6 26 24.5 (23) 28.5 10 32.5 31 (29.5) 35 15 40.5 38.5 (37) 42.5 20 33.5 41.5 39.5 (38) 43.5 25 44 52 50 (48.5) 54 32 Auto switch mounting and mounting dimensions are same as those for the standard type.
Auto switch capable Bore size Standard Stroke 1.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 2, 2.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 3.25, 4 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How To Order NC D A1 B 150 0400 A XC8 Adjustable Stroke Auto Switch Mounting Bore Stroke Adjustment Range A: 0~1 B: 0~2 Dimensions (in) Bore (in) MM KK A AA B C D DD E EA EE G K
10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) Note Symbol 02 Stations 2 stations Double wiring Note 1) 11 02 11 stations Pilot type 2 stations Specified layout Note 2) Internal pilot External pilot Nil R (Up to 23 solenoids possible) 20 20 stations A, B port size (Inch) A, B port size (Metric) P, E port Applicable series P, E port Applicable series A, B port A, B port
B B B AC20-D 1/8 1/8 M5 x 0.8 Width across flats 14 Width across flats 14 N.O.: Black N.C.: Gray B AC30-D to AC60-D B B B B B B Thread type/Rc, G: 10 One-touch fitting Thread type/NPT: 3/8" One-touch fitting Barb fitting applicable tubing: T0604 1/4 1/4 1/4 Width across flats 17 Width across flats 17 Width across flats 17 Standard specifications Bracket mount P1 P2 A B C E F G J K M N Q1
A B C D E F 20 2.13 1.97 .20 2.81 2.67 1.98 30 2.13 1.53 .20 2.81 2.67 1.98 50 1.50 1.53 .19 1.94 1.88 1.34 70 2.75 2.44 .20 3.44 3.31 2.61 MILLIMETERS SER. A B C D E F 20 54 50 5.2 71.3 67.9 50.4 30 54 38.9 5.2 71.3 67.9 50.4 50 38.1 38.9 4.8 49.2 47.6 34.1 70 69.8 61.9 5.2 87.3 84.1 66.3 COAST PNEUMATICS 8055 E.
Head side flange style: CQ2G/CDQ2G Without auto switch With auto switch Bore size (mm) 5 st 10 st 20 st 5 st 10 st 20 st A B L L1 32 40 50 28.5 53 58 43 48 7 28.5 59.5 64.5 49.5 54.5 7 33.5 77.5 67.5 67.5 57.5 8 Flange bracket material: Carbon steel Double Clevis Style 5 st 10 st 20 st 5 st 10 st 20 st 5 st 10 st 20 st 5 st 10 st 20 st 5 st 10 st 20 st 5 st 10 st 20 st A B CL Without auto
MY1B (Basic type) B A (mm) 10 16 20 Mounting position A 35 27 20 B 165 133 90 Operating range l Note) 8.5 6.5 6 MY1M (Slide bearing guide type) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B A (mm) 16 20 Mounting position A 70 90 B 90 110 Operating range l Note
2401 P3 JIS B 2401 P22 JIS B 2401 P5 131545 JIS B 2401 P5 131647 JIS B 2401 P5 131647 JIS B 2401 P5 JIS B 2401 G50 JIS B 2401 P6 JIS B 2401 G55 131336 JIS B 2401 P14 1.5-34 AR1000 to 6060 Dimensions AR1000 to 5060 Panel mounting hole AR1000 to 3060: Max. 3.5t AR4060/5060: Max. 5t AR6060 Model Port size A B C D M N P E F G H J K L Bracket mounting dimensions 25 40 53 53 70 75 90 95 11 15 25