Note 15) For an actuator with lock, add the power consumption for the lock.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
When disassembling a cylinder with a bore of 20 to 40, use a vise or the like to hold the wrench flats portion of the tube cover or the rod cover on one side, while placing a wrench or an adjustable wrench on the other side to loosen and remove the cover. To replace, tighten it an additional 28 from the installed position.
Manual Override How to Use L/M Plug Connector Caution Warning Attaching and detaching connectors Without an electric signal for the solenoid valve the manual override is used for switching the main valve. Locking type (Tool required) is available as an option.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Other dimensions are the same as the grommet style. [ ] for AC Other dimensions are the same as type 46.
52 46 55 63 69 S 33 36 40 46 50 52 Z 46 52 56 65 73 79 6 10 16 20 25 32 7 9 12 16 20 24 6 depth 4.8 6 depth 5 7.6 depth 6.5 9.3 depth 8 9.3 depth 9 11 depth 11.5 5 7 Free Mount Cylinder Double Acting, Single Rod Series CU Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 D-F9W 22 (24.5) ( ): Denotes the values of D-A93.
An approximate plate-end deflection X without a load is shown in the graph below.
-48 D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV 5.3-66 The output signal can be detected in an unsteady detecting area.
Therefore, if an external stopper is used to stop the piston rod and the lock is engaged, the piston rod will shift in the amount of its axial play. 6. To effect an intermediate stop, take the cylinders stopping precision and overrun amount into consideration.
Base mounted (with sub-plate) 65 (51) 1/8 61 (47) 60 (46) 82 (68) V100 Note) Value for DC. Add 1 g for AC. ( ): Without sub-plate.
There may be the case it will vary substantially depending on an ambient environment. 325 CHM Series Auto Switch Mounting Brackets: Part Nos.
Fix it to the detecting position with a set screw by installing an auto switch mounting bracket in cylinder tie-rod and letting the bottom surface of an auto switch mounting bracket contact the cylinder tube firmly. (Use a hexagon wrench.) 2. Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. 3.
If there is no buffer mechanism, an excessive impact force is generated. As a result, the tensile compression force of the floating joint may exceed its maximum level.
Air Piping Compressor Air Delivery Caution Caution HAA HAW IDFA55E, 75E Compressed air inlet Compressed air outlet Use an air compressor with an air delivery of 100 L/min or larger with the IDFA3E to 75E series.
Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. Sizes 20 through 32 have a built-in holding function for the unlocked state, allowing the unlocked condition to be maintained even without an air supply.
Do not install in Zone 0 (as defined in IEC 60079-101:2008) or Zone 20 (as defined in IEC 60079-10-2:2009) Zone 0 area classification: An area in which an explosive gas atmosphere is present continuously or for long periods or frequently.
Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. Sizes 20 through 32 have a built-in holding function for the unlocked state, allowing the unlocked condition to be maintained even without an air supply.