When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or Caution moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death Warning or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or Danger serious injury. Warning 1.
Cushion valves are provided with a crimp (32) or a retaining ring (40 to 100) as a stopping mechanism, and the cushion valve should not be opened above that point.
Use this as a guideline purpose only for model selection because the value varies depending on the material and/or size of a subject.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
Note 2) Voltage symbol 23 (230 VAC) and 46 (460 VAC) are the terminal block connection as standard. The option S cannot be chosen. Voltage symbol 11 (115 VAC) is the power cable with plug as standard.
+0.30 +0.10 Note) For a double clevis, a pin (cotter pin) and a flat washer are equipped as standard. +0.058 0 +0.058 0 +0.070 0 +0.084 0 +0.084 0 +0.084 0 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 14 19 24 26 26 36 20 22 28 40 40 46 30 40 50 60 60 92 M10 X 1.25 M14 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 M27 X 2.0 12 16 19 24 34 34 34 M10 X 1.25 M14 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5
P/A as a contact protection box may be necessary.
Cylinder with Lock Series MNB Taper ring Steel ball P f R R High locking efficiency Improved locking efficiency, as well as stable locking and unlocking (unlocking pressure 0.25MPa. 0.05MPa compared to conventional P/A products) have been realized by arranging a large number of precision steel ball bearings in two circular rows.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
As shown in the right figure, mount a crimped terminal o, and then again tighten the screw . Note) Tighten within the tightening torque of 0.5 Nm 15%. Note: a It is possible to wire even in the state of bare wire.
HRX-OM-Q026-V Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH Series HRSH100-A-20HRSH100-A-40HRSH100-A-20-S HRSH150-A-20HRSH150-A-40HRSH150-A-20-S HRSH200-A-20HRSH200-A-40HRSH200-A-20-S HRSH250-A-20HRSH250-A-40HRSH250-A-20-S HRSH300-A-20HRSH300-A-40HRSH100-W-20HRSH100-W-40HRSH100-W-20-S HRSH150-W-20HRSH150-W-40HRSH150-W-20-S HRSH200-W-20HRSH200-W-40HRSH200
When using a 5 port valve as a 3 port valve The 10-SV series can be used as normally closed (N.C.) or normally open (N.O.) 3 port valves by closing one of the cylinder ports (A or B) with a plug. However, they should be used with the exhaust ports kept open. They are convenient at times when a double solenoid type 3 port valve is required.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.