SMC Corporation of America
Elite Part Number Search
Search Results "HRSH250-AN-20-AS"

For an exterior dimension diagram to identify the mounting support types, refer to p.3.1-21 to 3.1-24 as the dimensions are identical to those of standard.

Also install a cleaning device such as an air filter or a mist separator on the secondary side as necessary.

Do not use in an environment where the product is directly exposed to liquid, such as cutting oils. If cutting oils, coolant or oil mist contaminates the product, failure or increased sliding resistance can result. 3. Install a protective cover when the product is used in an environment directly exposed to foreign matters such as dust, cutting chips and spatter.

Auto switch 2 15 2 15 Double vane type CDRB2BWU15/20/30-D Single vane type CDRB2BWU20, 30-S Dimensions for double vane type sizes 15, 20, and 30 are the same as those of single type.

Please See Below for How to Order Seal Kit 14* Rod Seal NBR Available only as an Assembled Item. Please See Below for How to Order Seal Kit 15* Piston Seal NBR Available only as an Assembled Item. Please See Below for How to Order Seal Kit 16* Cushion Valve Seal NBR Available only as an Assembled Item.

Auto switch 2 15 2 15 Double vane type CDRB2BWU15/20/30-D Single vane type CDRB2BWU20, 30-S Dimensions for double vane type sizes 15, 20, and 30 are the same as those of single type.

In this case, an intermediate stop can be performed only by using an external stopper, etc. Note 2) Depending on the operating environment, etc., order made products should also be reviewed. Note 3) An external guide system should be installed when over specifications. (Refer to page 6 for intermediate stops.) (Refer to pages 20 through 24.)

<18> 20 20 GA 19 17 17 13 B1 6 5.5 5.5 5 K 44 35.5 29 24 NA 9 7 7 7 RA 26 20 16.5 14 C 130 121 119 114 ZZ 14 10 8 6 KA 78 79 77 77 S 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 40 32 25 20 30 22 22 18 23 0<23> 0 0 10 0 0 0 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M14 x 1.5 M6 x 1 depth 12 12 12 1/4 1/4 3/8 1/2 58 58 27 27 32 41 14<12> 14<12> 10 10 10 10 23 20 20 20 11 11 58 72 20<17> 20<17> 16 16 71

DeviceNet compatible SI unit As a DeviceNet slave unit, it is capable of solenoid valve ON/OFF control up to a maximum of 32 points. In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.

The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.

, IDF6E-20 IDF8E-20, IDF11E-20 5 A IDU3E-20, IDU4E-20 IDU6E-20, IDU8E-20, IDU11E-20 [mm] Dimensions Model A B C D E F IDF22E-20 59 40 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 25 46 IDF37E-20 IDF22E-30 39 30 mA 125 10 A 60 60 IDF37E-30 IDF55E-30 148 81 50 36 IDF75E-30 133 73 IDU22E-30 151 74 200 V type IDF75E-30, IDU75E-30 15

The current target position data is sent D9004 Target position 4 as an encoder count value. Step Data number being executed is D9006 Step Data number executed 2 sent. (a) Positioning data (encoder count value) The current position data is sent as an encoder count value. Count value 1,000,000 has been fixed for 0 mm as a reference point.

One-touch fitting for 8 SUP/EXH block mounting position C8 Stations M 02 20 2 stations For 20 stations Mixed 20 stations Nil For 2 to 10 stations : One side (Same as direction of connector mount) For 11 to 20 stations: Both sides In the case of mixed specifications (M), indicate separately on the manifold specification sheet. 20 For 2 to 10 stations: Both sides Special specifications

Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as valves. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator. 4.

Applicable solenoid valves: Series 10-SY3 0, 10-SY5 0, 10-SY7 0, 10-SY9 0 2 4 6 2 4 6 2 4 6 2 4 20 40 45 60 3 5 7 9 X90 10 SY Model no. Entry is the same as standard products. Specifications and performance are the same as standard products.

An auto switch cannot be mounted on the same side as a motor. Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming approx. 30% dispersion). It may change substantially depending on the ambient environment.

For male thread When in the locked state, do not apply a load accompanied by an impact shock, strong vibration, turning force, etc. 30 Note that an external action, such as an impacting load, strong vibration, or turning force, may damage the lock unit or reduce its life.

as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 97 Thermo-chiller Standard Type HRS100/150 Series

Other functions such as data change are not covered.