100 V Relay, PLC Reed switch Solid state switch A54 100 V, 200 V Yes A33 PLC 12 V Terminal conduit 24 V 2-wire A34 100 V, 200 V Relay, PLC A44 DIN terminal Diagnostic indication (2-color indication) Lead wire length symbols: 0.5 mNil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Grommet A59W Y59A 3-wire (NPN) IC circuit 24 V 5 V, 12V Y7P 3-wire (PNP) Grommet J51 100 V, 200
Valve power PWR(V) supervision Enable Disable Enable WARNING: If safe PWR(V) monitoring is required for the application or if PWR(V) diagnostic is disabled on the device PWR(V) failures must be managed externally by other means.
F .G. + 24 V Brown (2 pcs.) + 24 VDC + + + 24 V Power supply 24 VDC 0 V 0 V 0 V DC/DC Blue (2 pcs.) 0 V F .G.
/ sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 11-3 Block diagram of the EX245-DX1 74 No.EX##-OMY0004 12.
B5 White Unused 1) NPN type Ionizer (IZS41, IZS42) When an ionizer (IZS41) is used in DC mode, make sure to ground the F.G. cable (green) and 0 V cable (blue) Shield Green: F.G. +24V F.G. Brown (2pcs.): +24 VDC + DC/DC + +24 V Power supply 24 VDC Blue (2pcs.): 0 V 0 V 0 V 0 V F.G. PLC INPUT Internal circuit F.G.
DO (n+1) 0 V DO (n) FE / Shield Output interface Output interface Short circuit Short circuit protection protection Output circuit / Output circuit / Bus interface Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 12-3 EX245-DY1 79
(A/D ) ( ) 6 2030 20 80 mA (Er1,2) () ( (Er4,6,7,8) ) DC1224 V DC1224 V Er1,2) Er4,6,7,8) 7 (HHH) "HHH" "LLL" Er3) (LLL) (Er3) 7F.S. -27No.PS-OMG0001CN-H No. DC1224 V DC1224 V 8 DC(+) DC(-) DC1224 V DC1224 V DC(+) 9 DC(-) / / 10 ( ) 11 / 5m / 12 2030 20 -28No.PS-OMG0001CN-H No.
5 V 12 V 3 wire (PNP) M9P IC circuit 2 Wire M9B 3 wire (NPN) M9NW 12 V Solid state switch 3 wire (PNP) M9PW IC circuit Diagnostic indication (2-color indication) 2 Wire M9BW 3 wire (NPN) M9NA 5 V 12 V Relay, PLC Yes 24 V 12 V Water Resistant (2-color indication) 5 V 12 V 3 wire (PNP) M9PA IC circuit 12 V 2 Wire M9BA 3 Wire (NPN equivalent) A96 IC circuit Yes 5 V Reed switch No 12 V 100 V
The length is 24 when any of the following auto switches are used: D-90/90A/S99(V)/ T99(V)/S9P(V). The length is 30 when any of the following auto switches are used: D-97/93A. 2. The angle is 60 when any of the following auto switches are used: D-90/90A/97/93A. The angle is 69 when any of the following auto switches are used: D-S99(V)/T99(V)/ S9P(V).
A2 Blue 0 V IN B2 A3 Green F.G. Make sure to ground with a resistance of 100 or less to use it as a reference electric potential for Ionizer. Signal input to turn ON/OFF the ventilation with fan and ion generation. NPN specification: Ventilation and ion generation is stopped by connecting to 0 V.
24 V Grommet Yes 3-wire(NPN) IC circuit Diagnosis (2-color indication) 5 V, 12 V 3-wire(PNP) 12 V 2-wire Auto switches marked with a symbol are produced upon receipt of order.
12 V 12 V Relay, PLC Grommet 24 V IC circuit 5 V,12 V Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) A96V A96 5 V IC circuit Grommet Relay, PLC A93V A90V A93 A90 IC circuit 100 V 24 V 12 V 2-wire 100 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked
IC circuit 3-wire (PNP) 2-wire 12 V Diagnostic indication (2-color indicator) Water resistant (2-color indicator) 100 V 3-wire (NPN) 5 V, 12 V IC circuit Relay, PLC Yes Grommet 24 V 3-wire (PNP) 2-wire 12 V 3-wire (NPN) 5 V, 12 V IC circuit M9PA1 M9PAV1 3-wire (PNP) 2-wire M9BA1 M9BAV1 12 V 5 V 12 V Relay, PLC Z76 Z732 A96 A93 A90 IC circuit 3-wire (NPN equivalent) Yes Grommet 24 V
Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
12 V 12 V IC circuit 5 V, 12 V Relay, PLC Diagnostic indication (2-color indicator) Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equivalent) Grommet 24 V A96V A96 IC circuit 5 V Yes A93V2 A93 A90 IC circuit 100 V Relay, PLC 2-wire 12 V A90V No 100 V or less 1 Water resistant type auto switches can be mounted
Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
Designation Description 1 SI24 V +24 V for SI unit operation 2 SV24 V +24 V for solenoid valve 3 SI0 V 0 V for SI unit operation 4 SV0 V 0 V for solenoid valve : Recommended mating M12 5-pin socket, part no. EX500-AP00and PCA-1401804. (Refer to page 40) The M12 connector cable has two types, SPEEDCON compatible and non-compatible.