Auto switch capable How to Order NC D A1 B 150 0400 + 0200 H XC11 R Mounting Bore size Auto switch Stroke B-A Dual operationSingle rod Stroke A Cushion Both ends N W/o cushions H Head end R Rod end Dimensions PA + Stroke B PB + Stroke A 4-EE (NPTF) 4-DD D across flats Stroke A Stroke B 4-NT Depth ND SN + Stroke A + Stroke B LF + Stroke A + Stroke B ZB + Stroke A + Stroke B Bore size (in)
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993: *2 : : : 1, 2 3 1 2 3 4 -3No.EX-OMN0037CN-A / 1 1.5 *3) *3) 1 1 () -4No.EX-OMN0037CN-A () () () () -5No.EX-OMN0037CN-A / , () * UL UL1310 Class2 0V -6No.EX-OMN0037CN-A * IP67 / *() ,, SI SI SI * IP67 M12M8 -7No.EX-OMN0037CN-A CE , * 20-23 PLC PLC * -8No.EX-OMN0037CN-A SI 1 SI 32 10 SI SI ON/OFF PNP NPN
MM BA AE AT AH D ACROSS FLATS G DD J AL AO S 6 AB (HOLE) LF + STROKE AO AL FA SA + STROKE X119 Option (in) Bore (in) MM KK A AA AB AE AH AL AO AT B BA C D DD E EA EE FA G J S WF Y P LF SA XA ZA 200 (2) 1 3/4-16 1 1/8 2.6 3/8 2 11/16 1 7/16 1 9/16 1/8 1.5 1 1/8 1/2 7/8 5/16-24 2 1/2 0.3 3/8 3/8 1.26 1.06 1 3/4 1 3/8 2.09 2.40 3 5/8 6 6 6 9/16 250 (2.5) 1 3/4-16 1 1/8 3.1 3/8 3 1/8 1 5/8 1
M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13
Shield 12 13 7 6 9 8 3 B-4 A-4 B-5 A-5 B-6 A-6 Brown Black Red Black Orange Black Vcc GND A A B B Connector B terminal no.
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: Operation
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None