/deceleration time constant (ms).
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Poriing No. of Ports 'xx" M84010-02 Ta"NPTFSide l l M84011-02 7a" NPTF Side: Y.r" Bottom A & B 1 3 MB 4210-02 %"NPTFSid(2); % Botlom(5) 7 t 5 Manifolds *(OptionsT & P Only) Part No. Poding No.of Ports "xx" Subplates .
Appearance Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure L1,L2,L3: Power supply PE: Ground 15 14 13 12 11 10 PE L3 L2 L1 Customer Connection Side Customer Connection Side Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2
View A L1 L2 L3 PE Inlet of the power supply cable Note: Prepare a cable tie. Fasten the power cable to the mount on the base with the cable tie.
Tap water: Standard of The Japan Refregeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
The time can be set in multiples of 1 ms. It should be noted that if a time of 100 ms or less is set in this object, the SI unit responds with an abort message. This object cannot be set to a time of 100 ms or less. Index 1029h Error Behavior The Status of the SI unit when a communication error occurs (Error control, Emergency object) is defined in this object.
power supply voltage AC 100 Solenoid valve combination symbol Pilot valve symbol Nil Y Nil Nil Y Nil Nil Nil AC 200 AC 110 AC 220 DC 24 DC 12 K1 K1 K2 J1 J1 J2 Q1 Q2 q w e r t y u i Combinations (1) to (8) in the above table are the only possible options. 13-9-2 3 Compact Vacuum Ejector Series ZQ How to Order ZZQ1 08 B B S Manifold Pilot exhaust port location Number of stations Note) 01 02
Please refer to the catalogue to confirm the sizes of the fittings to be used. n: Number of stations (mm) Dimensions 5 6 1 26 52 2 36 52 3 46 62 4 56 72 5 66 82 6 76 92 7 86 102 8 96 112 n L1 L2 EXH EXH P PE P PE V V V V Circuit ZQ13M-K1-D ZQ13M-K2-DK ZQ13M-J1-F ZQ13M-Q1-FK 9 Series ZQ Manifold Exploded View 6 3 6 4 6 b b view 4 6 2 a 5 a 5 5 Component Parts No.