Round type) 1 2 JA T-bracket 32 50 T-bracket 32 50 MXH Mounting nut and rod end nut are included in the basic weight.
, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) 1000 2 1 kVA Singlephase 2000 2 kVA 3 4 9 200 VAC (50 Hz
Therefore, also check the allowable load for the selected conditions. 6.1 10 16 20 25 32 40 MX 0.8 6.1 1.1 0.8 6.1 10.8 3.7 10.8 4.9 3.7 10.8 40 50 40 50 40 50 17.6 MTS 11 17.6 16 11 17.6 MY1H 27.5 23 27.5 26 23 27.5 30 30 30 39.2 MY 39 39.2 50 39 39.2 20 50 39 50 50 50 50 20 20 CY The above values are the maximum allowable values for moment and load.
, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 12, 16, 20 25, 32, 40 50, 63, 80 100 6, 10 15, 20 25, 32 12, 16 20, 25 32, 40 20, 25 32, 40 50, 63 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 12, 16 20, 25 6, 10 16 20, 25, 32 40, 50 10, 15 25 10, 16, 20 25, 32 6, 10 16 20, 25 32, 45 Bore size (mm) 5 to 50 mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50 mm/s Piston speed Air cushion on both
amount (mm) Plate displacement amount (mm) MGP MGPA16-250 MGPA16-250 0.35 MGPA -400 50 50 63 63 MGPA -400 50 63 0.6 0.3 50 50 63 63 MGPA -300 0.5 50 63 MGPA -300 MGPA16-150 MGPA16-150 MGPA16-100 MGPA16-75 0.25 0.4 MGP MGPA16-100 50 50 63 63 MGPA -200 50 63 MGPA -200 0.2 MGP MGPA16-75 0.3 0.15 50 50 63 63 MGPA -150 50 63 MGPA -150 50 63 MGPA -100 50 63 MGPA -50 0.2 50 50 63 63 MGPA -100 0.1
The operating speed range of the stroke marked with an asterisk (*) is 50 to 300 mm/s.
50 50 B 42 42 42 52 52 52 C 63 98 134 63 98 134 D 118.5 ZPT40H 25-A18 ZPT40H 50-A18 ZPT40H 75-A18 ZPT50H 25-A18 ZPT50H 50-A18 ZPT50H 75-A18 ZPT63H 25-A18 ZPT63H 50-A18 ZPT63H 75-A18 ZPT80H 25-A18 ZPT80H 50-A18 ZPT80H 75-A18 ZPT100H 25-A22 ZPT100H 50-A22 ZPT100H 75-A22 ZPT100H 100-A22 ZPT125H 25-A22 ZPT125H 50-A22 ZPT125H 75-A22 ZPT125H 100-A22 01 01 01 01 01 01 01 01 01 01 01 01 01 01 01
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).
NBR (50), Conductive silicon rubber (50) Durometer Spring Reactive Force Dia.
If the workpiece gripping point goes beyond the range limits, this will have an adverse effect on the life of the air gripper. 0.5 MPa 0.4 MPa 0.4 MPa 0.5 MPa 0.5 MPa 0.6 MPa, 0.7 MPa 0.6 MPa, 0.7 MPa 20 MHW 50 10 MRHQ 0 10 20 30 40 50 0 50 100 150 Misc.
1 L = 50 mm Max. speed = Over 200 mm/s !
65 60 Inrush Frequency (Hz) 50 45 55 50 65 60 50 60 50 60 50 60 50 60 50 60 50 60 9 7 19 16 30 25 11 8 20 18 32 27 VX21 VX21 VX22 VX22 VX23 VX23 Note) The values are for an ambient temperature of 20C and at the rated voltage.
No Stop with external stopper Stop with air pressure circuit Intermediate stopping method (Refer to p. 50 for intermediate stops.) Note 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation. In this case, an intermediate stop can be performed only by using an external stopper, etc.
denotes the bottom ported type. 3-6-12 13 Explosion Proof Solenoid Valve Series 50-VFE/50-VPE Specifications: 50-VFE3000/5000 Explosion proof solenoid valve 5 port/50-VFE3000, 5000 3 port/50-VPE500, 700 VK 50-VFE3000 50-VFE5000 Series VZ Fluid Air Quality of explosion proof spec.
LG1H/ Aluminum body LG1TH/ Stainless steel body LJ1 LG1 LC1 LX LC6D/LC6C Switches 50 10 10 50 Horizontal load 100% Horizontal load 50% 20 10 20 10 Horizontal load 100% Horizontal load 50% Amount of deflection m Amount of deflection m 500 1000 1000 500 200 100 200 100 50 20 50 20 10 10 5 5 Lateral load 100% Lateral load 100% 0.5 1 2 0.5 1 2 Lateral load 50% Lateral load 50% Horizontal empty
type) With indicator light/surge voltage suppressor (non-polar type) 5 24VDC 6 12VDC 1 100VAC 50/60Hz 2 200VAC 50/60Hz Note 1) "DOZ" is not available. 110VAC 50/60Hz [115VAC 50/60Hz] Note 2) "S" specification is not available for AC since it is integrated with the rectifier. 3 4 220VAC 50/60Hz [230VAC 50/60Hz] Electrical entry D With connector DIN terminal DO Without connector Note) When