Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.
Item Property Conductor resistance /km, 20C 65 or less Voltage limit V, 1 minute, AC 1000 Circular connector cable assembly Insulation resistance M/km, 20C Note) When using the negative COM specification, use valves for negative COM. 5 or more Assembly part no.
Lead wire length 0 1 2 0.6 m 1.5 m 3.0 m Electrical characteristics Item Characteristic Sheath Colour: Urban white Conductor resistance /km, 20C 65 or less Withstand pressure V, 1 minute, AC 1000 Polarity Terminal no. Lead wire colour Dot marking Insulation resistance M/km, 20C 5 or more 1 () (+) Black None SOL. A 14 () (+) Yellow Black Station 1 SOL.
Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.
Flow at 20C, atmospheric pressure, and 65% of the relative humidity The maximum flow capacity varies depending on the inlet pressure.
(Coil temperature : 20C, at rated voltage and without surge voltage suppressor) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Note 2) Safety allowance x3 at 20C Note 3) To calculate flow factor for longer lengths of tube divide factor for 1 metre by actual length in meters.
Flow rate conversion NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3kPa Standard state: 20C, 101.3kPa, 65%RH (ANR) Switchable between these states.
Note 2) Flow rate display can be switched between the basic condition of 0C, 101.3 kPa and the standard condition (ANR) of 20C, 101.3 kPa, and 65% RH. Note 3) Without lead wire. Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.
Standard Specifications/Single Unit (Standard Dew Point 20C) Membrane Air Dryer Series IDG Model Standard dew point: 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters. -20C low dew point just by installing in air pressure line.
The value of the minimum bending radius is measured at the temperature of 20C as shown below. KP LQ MQR Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. T T Fixed end IDK 3.
Note 2) The maximum operating pressure is the value at 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter change rate of 10% or less.
(mm) 7.3 5.8 4.4 2.8 8.8 Black (B) White (W) Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Blue (BU) Fixed end Translucent (N) Fluid Air 20C 0.8 Max.
MPa Proof pressure (20C) 20 to 80C Ambient and fluid temperature JIS B 0203 (Taper threads for piping) Thread Note 1) Refer to Particulate Generation Grade Classifications.
Features 1 New New 5 port solenoid valve series SY9000 Cv 2.8 (base mounted type with sub-plate) Interface regulator series ARBY3000/5000 (for series SY3000/5000) High speed response: 10ms (SY3000 single solenoid, 0.5MPa, 20C) (representative value) The innovative design of the pilot valve makes it possible to achieve a short response time of 10ms while consuming only a half watt of power
to 60C (No freezing) Fluorine-based grease AS-D AS-T Note 1) The maximum operating pressure is the value at 20C.
Speed Controller Cylinder Solenoid valve Tubing Silencer Max. return speed (mm/s) 10 20 30 6 ASD230FM CJ2 SYJ500 TU0604 1 m AN11001 10 16 Cylinder size 20 ASD330FM CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 32 Values are measured at 0.5 MPa and 20C.
to 60C (No freezing) Fluorine-based grease AS-D AS-T Note 1) The maximum operating pressure is the value at 20C.
FGF FGH FGH [Test conditions] Fluid: water / Test dust: ACFTD / Flow rate: 35 L/min Dust concentration: 10 mg/L / Temperature: 20C Element: EJ801S Schematic diagram of filtration efficiency data measuring circuit FQ1 EJ-2 m FN 100 99 Dust feeder Initial filtration efficiency (%) EJ-4 m EB ES Tank Flow meter EJ-6 m Differential pressure gauge EJ-13 m 95 Pressure gauge Downstream side sampling