SMC Corporation of America
Elite Part Number Search
Search Results "MLGCLB32-450-R-E"

MB MC KA MA N K N C S + Stroke H B ZZ + Stroke Allowable angle displacement of E to B is 1.5.

Description Material AMD150 AMD250 AMD350 AMD550 AMD650 AMD850 Glass fiber, Others Element assembly AMD-EL150 AMD-EL450 AMD-EL250 AMD-EL350 AMD-EL550 AMD-EL650 AMD-EL850 r Element assembly: With gasket and O-ring AMD800 to 1000 HA AT ID Component Parts AMG Model AMD800/900/1000 SGP-E, SS400 SGP-E, SS400 AMD801/901 Note No.

Symbol Name Initial value Unit PC01 STA Acceleration time constant 0 ms PC02 STB Deceleration time constant 0 ms PC05 SC0 Internal speed command 0 0 r/min PC06 SC1 Internal speed command 1 100 r/min PC07 SC2 Internal speed command 2 500 r/min PC08 SC3 Internal speed command 3 1000 r/min PC31 SC4 Internal speed command 4 [Applied] 200 r/min PC32 SC5 Internal speed command 5 [Applied] 300 r

Description Material AMF250 AMF350 AMF550 AMF650 AMF850 AMF150 Glass fiber, Others Element assembly AMF-EL250 AMF-EL350 AMF-EL450 AMF-EL550 AMF-EL650 AMF-EL850 AMF-EL150 r Element assembly: With gasket and O-ring AMF800 to 1000 HA AT ID Component Parts AMG Model AMF800/900/1000 SGP-E: SS400 SGP-E: SS400 AMF801/901 Note No.

Bracket (Option) Optional Specifications J: With drain guide u I T: With element service indicator T Maintenance , Drain space Dimensions with mounting bracket E~ment service indicator B E F G H I J Model Port size A C D K L M N 0 P Q R S T U 5 9 5.5 35 54 70 26 4.5 1.6 24 37 AMH150 1/8, 1/4, 3/8 159 20 63 20 76 20 76 20 90 20 90 20 106 20 106 20 122 20 160 10 166 56 15 10 187 66 20 10 187

A( ) A 24V 12V 100V SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 24V DC 12V DC 100V AC SOL SOL C(+) C ZNR Light DIN connector circuit with light AC circuit DC circuit 1 2 1 2 NL R R LED NL: Neon light R: Resistor LED: Emitting diode R: Resistor 4.3-2 Series VQ20/30 Manifold Caution Caution Valve Mounting How to Mount/Remove from DIN Rail After confirming the gasket is correctly placed under

F G S 6.0 , 2 1 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AFF75B 1 2 13 42 348 220 57.5 220 10 AFF75A to AFF220A/Dimensions 3-20 holes For anchor bolt mounting Label Drain Rc ORIENTATION G 184 184 236 12B AFF220A 4BJIS10k flange 500 1291 1070 670 325 282 Model A 8B B 380 380 450 C 1125 1125 1178 D 935 935 980 E 505 505 540 F 265 265 265 Port size AFF75A AFF125A AFF150A

The tightening torque should be 0.1 to 0.2 Nm. 5 to 6 14 e-Rodless Actuator Series E-MY2 Names and Functions of Individual Part Controller detail w t q u End Motor I/O cable Controller Power supply cable Slider i y e r Switch FG terminal Motor side end Description Content/Function q w e r t y u i Stroke learning switch Description Content/Function Switch to move the actuator to intermediate

Acceleration/ deceleration time 0 ~ 50 ms Set the time until the servo motor reaches/stops to the rated speed (3000 r/min) Move distance 0 ~ 2147483647 pulse Sets movement distance. -35- 6.6.2 Motor speed Configuration Motorspeed (r/min) configuration. * r/min (rpm): Indicated motor rotation speed (motor rotations/min) Rotation speed must be between 0 and the

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 50 20 40 Pressure loss (kPa) Pressure loss (kPa) 15 30 10 20 5 10 Flow rate (l/min) 0 200 0 50 100 150200250 300 400 350 450 500 20 50 100 150 Flow rate (l/min) Sensor Unit Construction PF2A710/750 PF2A510/550 Component Parts No. q w e r t Description

6For PROFIBUS DP K e For EtherNet/IPTM, PROFINET, EtherCAT, Ethernet POWERLINK K w and K e are used in combination with each other. K !4For PROFIBUS DP Terminating resistor Plug (Male) K tFor CC-Link K oFor DeviceNetTM Socket (Female) K uFor CC-Link K !2For DeviceNetTM Connects to the communication port of the communication unit connected at the end K !3 K !8 K !

BM51 BM52 BM53 BM54 BM55 BM56 BM57 How to Order AME 250 03 R B Option R INOUT reversal Body size HAl Accessories (Options) 150 250 350 450 550 650 850 1/8 1/4 3/8 1/2 3/4 None B AT With bracket IDl Port size 1/8B 01 02 03 04 06 10 14 20 2B 1 Thread 1/4B AMG 11/2 3/8B Rc(PT) F G(PF) N NPT 1/2B AFF 3/4B 1B AMl 11/2B Symbol Related poroducts AME Note) Refer to p.4.7-7 for "How to Order" case

f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .

2 y q e !3 o !0 With auto switch (Built-in magnet) 32 to 63 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !2 r t i !4 y q e !3 o w u !0 !1 M: Rod end male thread Component Parts Replacement Parts: Seal Kit No. Description Material Note Bore size (mm) Kit no.

Model number Serial number Type and quantity of refrigerant How to read the serial number y R 001 April 2020 W R 001 Year Symbol Remarks Month Symbol Remarks Serial no. 4 R Repeated from O to Z in alphabetical order, with O for January and Z for December 2020 y 2021 Z 5 S Repeat ed from A to Zin alphab etical order 2022 A 6 T Fig 1-1 Position of product label HRR Series 1.4 Product Label

Air operated style fluid control valve Vacuum valve Vacuum pad 2(A) 1(P) 2(A) 1(P) 2(A) 1(P) 2(A) 3(P) 3(R) 3(R) 3(R) 1(R) Atmospheric air or micro pressure for vacuum release 22 Multi-purpose Valve Series VCA Direct Operated 2 Port Solenoid Valve for Air Improved durability (Nearly twice the life of the previous series) Operating resistance of moving parts reduced for improved longevity