Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female Rod
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Through hole, Body Options: Female Rod
Magnet: Built-in, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 9/16", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Both Ends Tapped, Overall Length: Super Compact, Bore Size: 1 1/2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 2 1/2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Rear Clevis, Overall Length: Standard, Bore Size: 2 1/2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Rear screw clearance hole, Overall Length: Standard, Bore Size: 1 1/2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Through Hole, Overall Length: Standard, Bore Size: 2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 1 1/16", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 2 1/2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 1 1/16", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Both Ends Tapped, Overall Length: Standard, Bore Size: 3/4", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: None, Mounting: Both Ends Tapped, Bore Size: 2", Stroke: 4", Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Scraper
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Screw Clearance Hole, Front Mount
Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 4", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Screw Clearance Hole, Through,
The CM2-XC4 double acting, single rod, stainless steel cylinders are compact, lightweght and offer high performance and at least 6 times superior durability in dudsty environments. The CM2-XC4 is suitable for environments with ceramic powder, toner powder, paper powder and metallic powder.
The CG1-XC4 double acting, single rod cylinders offer high performance and at least 6 times superior durability in dusty environments. The CG1-XC4 is suitable for environments with ceramic powder, toner powder, paper powder, and metallic powder. The CG1-XC4 employs the same specifications and dimensions as the existing CG1 air cylinder models.
The CG1-XC4 double acting, single rod cylinders offer high performance and at least 6 times superior durability in dusty environments. The CG1-XC4 is suitable for environments with ceramic powder, toner powder, paper powder, and metallic powder. The CG1-XC4 employs the same specifications and dimensions as the existing CG1 air cylinder models.
The CM2-XC4 double acting, single rod, stainless steel cylinders are compact, lightweght and offer high performance and at least 6 times superior durability in dudsty environments. The CM2-XC4 is suitable for environments with ceramic powder, toner powder, paper powder and metallic powder.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ8 COMPACT CYLINDER, NC, 2" NCQ8 OTHERS (COMBO)