Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N7 (ø1/4 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 02 (Rc1/4), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: 6, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence, Display:
Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: [8] 8(5/16inch), Liquid contact parts material: Resin + Metal, Mounting Hole: Presence
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: -, Calibration Certificate: -, Connector: -, Option: -
6604113 660651 660651 Possible to check outlet dew point with an indicator 1/4"NPT 1/2"NPT 1/2"NPT 3/4"NPT Accessories Recycled Air 0.71 1.31 6.89 ID200-N02 ID300-N04 ID400-N04 ID600-N06 3 20 37 85 195 Add Z at the end of model no. for 58F dew point. 2.82 5.47 11.65 27.54 Outlet Model Flow 80 155 330 780 Specifications 3.53 6.78 14.65 34.43 Dimensions Inlet L/min 100 192 415 975 Features:
ARX Series Specialty Regulators Regulator for 290psi (2MPa) ARX20, 21 Specifications ARX20 Model Piston regulator Regulator construction Relief type Relief mechanism NPT 1/8, 1/4 Piping port size NPT 1/8, 1/4 Pressure gauge port size 435 (3.0) Proof pressure psig (MPa) 290 (2.0) Maximum operating pressure psig (MPa) ARX20-N02 7~120 (0.05 to 0.85) Standard Regulating pressure range psig (MPa
Speed Controller/In-line Type AS2000-N02-X800/AS3000-N03-X800/AS4000-N04-X800 P .G. information Point to Group Specialized Product Flow Characteristics AS3000-N03-X800 AS4000-N04-X800 AS2000-N02-X800 300 800 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 1500 250 600 200 1000 150 400 100 500 200 50 0 0 1 2 3 4 5 6 7 9 8 10 0 0 1 2 3 4 5 6 7 9 8 0 0 1 2 3 4 5 6 7 8 Number
N F.O.F. 2 x 1 8 3 x 1 4 P.T.
(Ex.: AN200-N02) AN600-10 270 1 1 1 AN700-12 440 1 4 AN800-14 590 1 2 AN900-20 960 2 Note) NPT thread is also available. Specify N after ANm00-.
0.1 -70 0.01 Food & Beverage, Pharmaceuticals 1 3/2 1 Odor Removal 2 1 -40 0.1 Instrumentation 1 3/2 2 3 5 -20 1.0 Abrasive Blasting 3 3 4 15 +3 5 Spray Painting 1 4/3 3 5 40 +7 25 Automation / Robotics 3 4/3 3 6 +10 Basic Air Cylinders 3 4/5 4 Outdoor Pipelines 1 2/3 1 Packaging Machines 3 4/5 3 Hand Air Tools 3 4/6 4 A Series Compressed Air Filters The selection of an air filter should
Assembly NARM2500 NARM3000 1 Body Aluminum die casting Chromate/Platinum silver painting Component Qty. Description No. 2 Common IN Individual IN Common IN Individual IN Bonnet Polyacetal Regulator NARM2500-A-N02 NARM2500-B-N02 NARM3000-A-N03 NARM3000-B-N03 9 Regulator 1 Component Parts 10 End plate R 1 No.
G36 P4 N01 G46 P4 N02 1348110A B Regulating pressure range Bracket 0.05 to 0.85MPa 0.05 to 0.30MPa 0 1 ARX20 Nil F ARX21 Nil F Thread type G Pressure gauge Rc NPT G Nil N F ARX20N ARX21N P Port size Panel nut 1/8 1/4 01 02 Option combination numbers Panel nut is also included with B.
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)