HUMIDITY SENSOR. CONDENSATION CHECKER. 103.00000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 103.00000 lb. Q62.
type lead wire is only applicable to D-A93. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ * Auto switches marked with v are produced upon receipt of order. * Auto switches are shipped together, (but not assembled). * Refer to pages 837 and 838 for detailed solid state auto switches with prewired connectors. 188 Rotary
Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Since there are applicable auto switches other than those listed above, refer to page 30 for details. The D-A9l/M9l/P3DWAl auto switches are shipped together, but not assembled.
Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Besides the above models, there are some other auto switches that are applicable.
(1.64 ft) L 3 (m) (9.84 ft) Z 5 (m) (16.4 ft) For standard part number please see applicable auto switches on page 44 50 For standard part number please see applicable auto switches on page 44 50 Connector type A M8-3 pins B M8-4 Pins D M12-4 Pins Lead wire length S 0.5 (m) M 1.0 (m) L 3.0 (m) Auto Switch Mounting Bracket/Part No.
1, @2 and @6 each. 12 MXY12-PS 8-9-11 11 Series MXY Dimensions 2-M5 x 0.8 Piping port J + Stroke Same in case of the type of centralized piping on one side without switch rail ( ) JH Piping port (Plug: M-5P) 2-M5 x 0.8 (Plug: M-5P) 2-M5 x 0.8 Piping port FL 21 21 FH 2-M thread depth MM +0.03 0 Width across flats MB (lock plate fixing bolt) R 4-M thread depth MM PR RL PR +0.03 0 MA (Stroke
Weight of total loads: Wo (kg) Wo = (Load weight: WA) + (Jig weight: WB) 4.
NO m: Refer to "Operating Conditions (Allowable eccentric load)" on page 12. m < Wo NO mo Wo m Wo mo < Wo YES mo Wo YES m Wo Model selected Allowable rotational torque Non-rotating accuracy T T (Nm) Non-rotating accuracy Bore size (mm) Stroke (mm) Bore size (mm) 40 0.08 100 75 50 30 63 40 0.06 3 4 5 7 100 63 0.05 10 12 16 22 100 13 17 22 30 Note) The value given for the non-rotating
NO m: Refer to "Operating Conditions (Allowable eccentric load)" on page 12. m < Wo NO mo Wo m Wo mo < Wo YES mo Wo YES m Wo Model selected Allowable rotational torque Non-rotating accuracy T T (Nm) Non-rotating accuracy Bore size (mm) Stroke (mm) Bore size (mm) 40 0.08 100 75 50 30 63 40 0.06 3 4 5 7 100 63 0.05 10 12 16 22 100 13 17 22 30 Note) The value given for the non-rotating
M type connector w/ plug and 300 mm lead wire MO M type connector w/o plug and lead wire MN M type connector w/ plug and pins Air Operated Valve DXT474-A Valve Manifold Assembly DXT475 A * * * * * * 02 * Valve Actuation Type Sup.
HUMIDITY SENSOR. CONDENSATION CHECKER. 158.80000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 143.00000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 114.60000 lb. Q62.
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 142.00000 lb
HUMIDITY SENSOR. CONDENSATION CHECKER. 168.50000 lb. Q62.
HUMIDITY SENSOR. CONDENSATION CHECKER. 168.50000 lb. Q62.
2 M4f.7 optr-8 1.57 (40) 276 o0) 0.13 (x2l 0.79 (m) 0.79 \20) 6.95 076.5) 'Remove drain cock to obtain 1/4 pipe lhread (220 only) Typical Applications r t l -i-E-:I I I ; | | | ' \t/ H World Wide ?gtC Support... United States Branch Offices Europe ENGLAND SMC Pneumatics (U.K.)
Stations: 9 Stations, Port Size: N3 (5/32" One-touch Fitting), Cable Length: 0 (w/o Cable 25 Pin), Option 1: D (DIN Rail Mounting), Option 2: RT (External Pilot, Branched P & R Ports on U Side)
Input Specifications: 0 (Voltage Input), Output Specification: RT [2 Outputs (NPN/PNP Switching Type) + Analog Voltage Output], Unit Specification: Units selection Function; for Overseas use only; SI Unit provided for Use in Japan, Lead Wire: L (Power Supply/Output Connection Lead Wire, 2m), Bracket/Panel Mount: A2 (Bracket B, Horizontal Mounting), Sensor Connector: C (Sensor Connector, for