Tubing Size: 2522 (ø25 O.D. x ø22 I.D.), Color Indication: N (Translucent), Length Per Roll: 50m Roll
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT W/LOCK, SW CAP, ACTUATOR, RLQ COMPACT LOCK CYLINDER, NE, 50MM RLQ DBL ACTING, AUTO-SW
Magnet: D (Built-in Magnet), Mounting: L (Foot), Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread: TN (NPT), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: B [Through Hole (Standard)], Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 25mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: L (Foot), Bore Size: 32mm, Port Thread: Rc: 32 to 100 Bore; M Thread: 20, 25 Bore), Stroke: 50mm, Body Option: M (Rod End Male Thread), Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 50mm, Thread Type: TN (NPT), Stroke: 50mm, Rod End Nut: M (Male Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 40mm, Thread Type: Rc, Stroke: 50mm, Rod End Nut: M (Male Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 40mm, Thread Type: Rc, Stroke: 50mm, Rod End Nut: M (Male Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 50mm, Thread Type: Rc, Stroke: 50mm, Rod End Nut: M (Male Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket
Magnet: Built-in, Mounting: Basic, Bore Size: 40mm, Thread Type: Rc, Stroke: 50mm, Rod End Nut: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: 50mm, Thread Type: Rc, Stroke: 50mm, Rod End Nut: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: 40mm, Thread Type: Rc, Stroke: 50mm, Rod End Nut: Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Built-in Magnet: With Magnet, Mounting Style: Standard, Bore Size: 63mm, Stroke: 50mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -