Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
CDA2 B 50 200 X1184 B31J S With built-in special magnet Number of auto switches Cylinder stroke Description 2 pcs. 1 pc.
Item XL -25 XL -40 XL -50 XL -63 XL -80 Rated heater voltage 90 to 125VAC 200/10 200/20 400/40 400/60 600/100 Heater power W (nominal value) In-rush/Normal (Option symbol) H1 80C (176F) 200/40 200/60 400/100 600/150 H2 100C (212F) 200/30 400/70 400/80 600/130 800/180 H3 120C (248F) Note) In-rush current will flow to the heater for approximately 30 seconds and will then subside.
Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
100% Horizontal load 50% Horizontal load 100% Horizontal load 50% 50 100 200 50 100 200 20 20 10 10 5 5 Lateral load 100% Lateral load 50% Lateral load 100% Lateral load 50% 1 2 1 2 0.5 0.5 Horizontal empty weight deflection Lateral empty weight deflection Horizontal empty weight deflection Lateral empty weight deflection 0.1 0.2 0.1 0.2 100 200 300 500 1000 100 200 300 500 1000 Load point
For Air 1.0 Downstream pressure of valve (P2) [MPa] Upstream pressure of valve P1z1.0 MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 3/64 (1.2) 50 100 150 3/32 (2.4) 100 200 300 400 1/8 (3.2) 300 200 100 400 500 600 700 5/32 (4) 200 1, 000 800 400 600 7/32 (5.6) Series VXN2 250 500 7/32 (5.6) Series VXN3 500 1, 000 1, 500 2, 000 Flow rate Q [L/min
50 Drain port 1/4 100 200 100 400 674 200 696 (mm) A 481 520 444 477 B 394 429.8 394 429.8 C 3/8 1/2 3/8 1/2 D Note) 469 493 Booster regulator model The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
0.5 1000 1000 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 200 200 100 100 40 32 30 40 50 30 40 50 25 40 20 32 Load weight: m (kg) Load weight: m (kg) 20 20 [Example] 25 10 10 20 5 4 5 4 3 3 2 2 1 1 0.5 0.5 100 500 400 300 200 100 500 400 300 200 1000 1000 Maximum speed: V(mm/s) Maximum speed: V (mm/s) Graph 7 Graph 4 0.5MPaP 0.5MPaP 200 200
Coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Note) For the special voltages, please consult with SMC.
10, 20, 30, 40, 50 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 Refer to "Made to Order" on page 51 for long strokes (i.e., strokes beyond the standard stroke range).
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 1000 1000 100 80 500 400 300 500 400 300 63 63 100 80 200 200 50 40 50 100 100 63 Load weight: m(kg) Load weight: m(kg) 32 50 40 50 40 30 50 40 30 32 20 20 [Example] 10 10 5 4 3 5 4 3 2 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Maximum speed: V(mm /s) Maximum speed: V(mm/s) Graph 7 Graph 4 0.5MPaP 0.5MPaP
/60 Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
0.5MPaP 200 200 40 100 100 32 30 40 50 30 40 50 40 25 20 32 Load weight: m (kg) Load weight: m (kg) 20 20 25 20 10 10 5 4 3 5 4 3 2 2 1 1 0.5 0.5 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) 1000 1000 Maximum speed: V(mm/s) Note: 1kg = 2.2046lb 1MPa = 1450psi 1in = 25.4mm 20
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bore size (Stroke (mm)) 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Auto switch Nil Without
, 200 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 1/8 Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Non-lube Double acting, Up to 1500 25, 50, 75, 100, 125, 150, 200 Single rod (40 to 63) 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note 1) When exceeding the standard strokes above, the particle generation class may not be satisfied
rod CQP2 Double acting 7-6-88 Spring return/ 12, 16, 20 25, 32, 40 50 Single acting 12 to 40/5, 10 50/10, 20 Spring extend CQP2 7-6-98 Large Bore Size 125, 140 160, 180 200 Single rod CQ2 7-6-108 10 to 300 Double acting 125, 140 160, 180 200 Double rod CQ2W 7-6-115 10 to 300 Long Stroke 32, 40, 50 63, 80, 100 Single rod CQ2 Double acting 7-6-121 125 to 300 Anti-lateral Load Single rod CQ2S
-50 MXQ25-50 MXQ25-30 MXQ25-30 MXQ25-50 MXQ25-50 MXQ25-125 MXQ25-125 MXQ25-30 MXQ25-50 MXQ25-125 0.08 0.06 MXQ25-20 MXQ25-20 MXQ25-20 0.04 MXQ25-20 MXQ25-20 MXQ25-20 0.04 MXQ25-10 MXQ25-10 MXQ25-10 MXQ25-10 0.04 0.02 0.02 0 0 0 800 200 400 600 100 200 300 400 500 100 200 300 400 500 Load (N) Load (N) Load (N) 8-5-13 14 Series MXQ Model Selection Model Selection Step Formula/Data Selection
Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.