Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 3 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 4 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 5 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 9 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 18 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 20 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 13 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 16 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 12 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 8 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 6 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 14 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 15 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 7 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 2 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 3 Stations
Port Size: A02 [Stacking Base Type (Barb Fitting: ø6/ø4, Tubing: ø4/ø2.5)], Stations: 4 Stations
(Coil temperature: 20C, at rated voltage) Use of the product under the conditions and environment below may cause delay in the response (switching) of the valve during start-up. qThe first operation after a long period of inactivity wWhen using at low supply pressure (0.1 MPa or less) eWhen using in an environment where the ambient and fluid temperature is low (10C or less) *4 The flow rate
. -10C Refrigerant circuit failed. Check that the ambient temperature, heat load satisfy the specifications. Check that the circulating fluid flow rate is more than the minimum flow rate.
When the ambient temperature or circulating fluid temperature is 10C or below, use the circulating fluid specified in "3.2.2 Operation at low ambient temperature or low circulating fluid temperature". For the product installation or operation in accordance with UL standards, see below.