CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing June, 2003 D-DN P-120 (DN) Printed in Japan.
36.5 43.5 41.5 78 88 CH2F 41.5 36.5 41.5 36.5 41.5 76 86 50 CH2H 42 36 42 36 42.5 40 77 87 CH2E 47 43 48.5 43 50.5 47.5 85 95 CH2F 46.5 43 46.5 43 48.5 83 93 63 CH2H 47 43 48.5 43 50.5 47.5 85 95 CH2E 57 55.5 58.5 55.5 59 55.5 93.5 103.5 CH2F 80 56.5 55.5 56.5 55.5 57.5 92 102 CH2H 57.5 55.5 59 55.5 59.5 56 94 104 CH2E 66.5 67 66.5 67 69.5 65 104 114 CH2F 100 65.5 67 65.5 67 68 102.5
43 43 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21 21 16 16 18.5 30 35 35 40 40 50 50 56 27 32 32 37 37 47 47 53 11 11 11 11 11 16 16 18.5 60 70 86 102 116 145 161 182 MGC MGF CY1 MY1 In installing an air cylinder, if a hole must be made to accommodate the rod portion, make sure to machine a hole that is larger than the boot outer diameter "e" W/o rod boot W/ rod boot Bore (mm) 40 50
12 I 12 5 21 8 6 21 8 6.2 27 ZPT40g 40 43 18.5 6 8 6.2 32 6.5 3.3 2PTSOl!
Description Material 1 Rod Cover Aluminum alloy NCA200-02AQ3609-S NCA200-03-Q3609-S NCA250-02AQ3610-S NCA250-03-Q3610-S NCA325-02AQ3611-S NCA325-03-Q6311-S 2 Head Cover Aluminum alloy 3 Cylinder Tube Aluminum alloy Please See below for How to order Cylinder Tube 4 Piston Rod Carbon steel Available only as an Assembled Item.
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing January, 1998 D-SMC.L.A. P-76 (M)
Parl No. naq. 1A MB aO20.03 tg Ba &2041 1C MB 4@1-03 lD MB12-O3 121 Manlfold Block #.{1 Mrnlfold Slock *23 Manlfold Block ,28 Manltold Block l{ol} Us lor mountlno NVS ln24 valvs.
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C (4F)) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa (psi) 0.3 to 0.85 (43 to 123) 0.3 to 1.0 (43 to 145) Inlet air temperature C (F) Note
(15A) 10 2.4 43 1 2 420 Note) Refer to p.4.0-14 the glossary for detail of max. operating pressure differential and max. system pressure.
40 48.5 43 50 43 85 95 80 50 50 55.5 50 56 51 57 51 59 93.5 104 100 59 59 63 59 63.5 58.5 65 58.5 70 104 114 The auto switches listed below cannot be mounted on 63.
43 43 22 27 27 32 41 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21 21 16 16 18.5 11 11 11 11 11 16 16 18.5 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 M14 x 1.5 M14 x 1.5 M16 x 1.5 6 7 7 11 11 15 15 17 14 18 18 22 26 31 31 36 Note) In installing an air cylinder, if a hole must be made to accommodate the rod portion, make sure to machine a hole that is larger than
Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
43 43 22 27 27 32 41 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21 21 16 16 18.5 11 11 11 11 11 16 16 18.5 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 M14 x 1.5 M14 x 1.5 M16 x 1.5 6 7 7 11 11 15 15 17 14 18 18 22 26 31 31 36 Note) In installing an air cylinder, if a hole must be made to accommodate the rod portion, make sure to machine a hole that is larger than
Applicable bore size B (C) (D) d H NT-02 20 13 (15.0) 12.5 M8 x 1.25 5 NT-03 25, 32 17 (19.6) 16.5 M10 x 1.25 6 NT-04 40 22 (25.4) 21.0 M14 x 1.5 8 Part no.
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.
(Total Travel) 40 Hexagon nut thick 5, across flats 17 (Pilot exhaust port) JIS Symbol 0.5 MPa supply 2-3.2 mounting hole 15 N F.O.F. 40 T.T. 5-6-44 43 5 Port Mechanical Valve Series VZM500 Series VZM500 Push button (Mushroom) VZM550-01-30R/B/G/Y Panel mounting hole SA (Pilot exhaust port) JIS symbol VA SA VA VM 0.5 MPa supply Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San
Inch size Millimeter size Port size 5/32 04 03 4 M5 M5 x 0.8 Thread type 1/4 06 07 6 U10/32 10-32UNF 5/16 08 09 8 Metric system thread (M5) 01 1/8 3/8 10 11 10 Nil Unified thread (10-32UNF) 02 1/4 1/2 12 13 12 Rc(PT) 03 3/8 N NPT 04 1/2 Check valve free flow direction Applicable Tube O.D.
For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire
8.4 Cooling Capacity 8-13 HRX-OM-Q026 Chapter 8 Documents 8.4.3 HRSH200-A-20/4030 Ambient temperature: 32 oC 25 Cooling capacity [kW] 20 Ambient temperature: 43 oC 15 Ambient temperature: 45 oC 10 5 0 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Fig. 8-9: Cooling Capacity (HRSH200-A-20/40-) 8.4.4 HRSH250-A-20/4030 Ambient temperature: 32 oC 25 Ambient temperature: 43 oC Cooling