The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. VALVE, SUB PLATE. VALVE. SV4000 NO SIZE RATING. .51260 lb. 2I.
The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation SV4000 SOLENOID VALVE. VALVE, DBL SOL, PLUG-IN. VALVE. SV4000 NO SIZE RATING. 1.58675 lb. 2E.
Free 300/50 VPA342: VP300-27-1A VPA542: VP500-27-1A VPA742: VP700-27-1A Bracket (With screw) Option N.C. N.O. Note) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal ON and OFF.
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
[Option] Electrical entry D: DIN terminal DO : DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) Rated voltage Valve option Rated voltage Nil V Y W E DC AC CE-compliant 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz For the connector part number, refer to page
Main applications Nominal filtration accuracy (m) Material Core material Stainless steel 304 0.5, 1, 5, 10, 20, 50, 75, 100 Cotton 0 to 60 0.5, 1, 5, 10, 20, 50, 75, 100 0.2 MPa 0.1 MPa Polypropylene Polypropylene 0 to 400 Glass fiber Stainless steel 316 1, 5, 10, 20 Note) Size for all is 65 x L250.
Main applications Nominal filtration accuracy (m) Material Core material Stainless steel 304 0.5, 1, 5, 10, 20, 50, 75, 100 Cotton 0 to 60 0.5, 1, 5, 10, 20, 50, 75, 100 0.2 MPa 0.1 MPa Polypropylene Polypropylene 0 to 400 Glass fiber Stainless steel 316 1, 5, 10, 20 Note) Size for all is 65 x L250.
Applicable manifold base model VP300-25-1A VV3PA3 Blanking plate assembly (With a gasket and two mounting bolts) VP700-25-1A VV3PA7 VP500-25-1A VV3PA5 1569 VPA300/500/700 Series How to Order Valve (With a gasket and two mounting bolts) VPA 3 4 4 1 A Type of actuation A B N.C. (Normally closed) N.O.
Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
Example: SS3YJ3-20-03.1 set (Manifold base) SYJ312-5LZ-M3.2 sets (Valve) SYJ300-10-1A.1 set (Blanking plate assembly) SS3YJ3-42R-03-C4 .1 set (Manifold base) SYJ314R-5G.2 sets (Valve) SYJ300-10-2A. 1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
40 53 53 70 70 90 95 95 33 50 64 64 84 89 105 105 110 25 30 41 41 50 50 70 70 70 20 24 35 35 40 40 50 50 50 AC1000 AC2000 AC2500 AC3000 AC4000 AC4000-06 AC5000 AC5500 AC6000 17.5 22 34.2 34.2 42.2 46.2 55.2 55.2 55.2 1/8, 1/4 194 194 229 230.5 309.5 323.5 323.5 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 1 Option For piping adapter AC2500, 3000, port size 1/2: 40mm, For AC4000, port size
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
75.2 40 9 18 5 48 AC40-06-B 3/4 1/8 235.4 149.1 37.8 38.4 77.6 110 33.8 3 50 80.2 40 9 18 5 48 AC50-B 3/4, 1 1/8 282.4 220.1 41.2 93.1 110 43.3 3.2 70 96.2 50 11 20 6 60 AC55-B 1 1/8 292.4 234.1 44.7 98.1 110 43.3 3.2 70 96.2 50 11 20 6 60 AC60-B 1 1/8 297.4 234.1 44.7 98.1 110 43.3 3.2 70 101.2 50 11 20 6 60 Optional specifications Semi-standard specifications Metal bowl with level
VCA20-12-1A VCA30-12-1A VCA40-12-1A Connector Mounting screws (2 pcs.)
SZ3000-73-1A-L6 SZ3000-73-2A-L4 SZ3000-73-2A-L6 SZ3000-56-1A VVQ1000-51A-C6 VVQ1000-51A-C8 SZ3000-74-1A-L6 SZ3000-74-1A-L8 SZ3000-74-2A-L6 SZ3000-74-2A-L8 4(A), 2(B) port 1(P), 3(R) port Other Tube Brands Caution 1.