Station 7 SOL.B () (+) 14 Blue White 16 SOL.A () (+) 15 Purple None 17 Station 8 SOL.B () (+) 16 Gray None 18 SOL.A () (+) 17 Orange Black 19 Station 9 SOL.B 30 () (+) 18 Red White 20 SOL.A () (+) 19 Brown White 21 Station 10 SOL.B () (+) 20 15 14 2 1 Pink Red 22 Terminal no.
30 30 40 45 50 57.5 63.5 69 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 36 46 53 30 30 30 59 71 82 46 55 66 45 55 68 58 67 73 21 26 32 23.5 28 34.5 34.5 40 46.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) N NB P S XA XL Y WL WM ZZ M MA MB MC MM 40 50 63 44 50 56 74 83 89 1/4 1/4 1/4 168 183 204 12 16 16 6 6 6 9.5 12.5 15 42 42 52 10 14 14 18 18 18 4 5 5 12 15 15 M6 x 1.0 M8 x
Note) Electric current should be 1A or less.
(off) Differential 15 88.7 67.6 23 35 14 AC4000, AC4020, AC4030 IS1000M-4Y AW AC4000-06, AC4020-06 AC4030-06 15 91 68 23 44 14 IS1000M-5Y AMR AC5000, AC5500, AC6000 AC5020, AC5520, AC6020 15 100 72.5 23 54 15 IS1000M-6Y Switch Characteristics AWM Contact point structure 1a Max. contact point capacity 2V AC/2W DC Voltage AC, DC 12V, 24V, 48V, 100V AWD AC, 12V to 24V DC: 50mA AC, 48V DC: 40mA
Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
*15 *15 *15 *15 *15 *15 *15 ZA*14 Digital pressure switch: With unit selection function *16 *16 *16 *16 *16 *16 *16 *16 *8 The only difference from the standard specifications is the adjusting spring for the regulator.
Single valve unit VCC12(D)-02(F) 38.7 16.5 Rc1/8 pilot (12) port G1/4, Rc1/4 IN(1) port 15 2 x 6 (for M5 mounting) G1/4, Rc1/4 OUT(2) port 48 6 22 22 6 25 25 43 15 15 M5 leakage detection port 23 30 22 Part number for sub-base VCC12-S02 02F [Rc1/4] [G1/4] 60 0.5 to 2 Sub-base material is aluminum + hard anodized containing PTFE.
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
30 40 48 30 40 48 15 15 20 24 15 20 24 62.5 73.5 72 75 78 76.5 79.5 30 35 35 35 40 40 40 9 9 9 20 22 22 22 24.5 24.5 24.5 8 8 9 14 8 9 14 15 15 22.2 19 15 22.2 19 18 18 22.2 20.6 18 22.2 20.6 6.4 6.4 7.6 6 6.4 7.6 6 27 29.5 29.5 29.5 32 32 32 44 54 52.5 53.5 58 56.5 57.5 30 32.5 32.5 32.5 35 35 35 30.5 40 38.5 39.5 44.5 43 44 2 11 9 9 3 11 Conduit terminal DIN terminal Size Port size P Q
SZ3000-73-1A-L6 SZ3000-73-2A-L4 SZ3000-73-2A-L6 SZ3000-56-1A VVQ1000-51A-C6 VVQ1000-51A-C8 SZ3000-74-1A-L6 SZ3000-74-1A-L8 SZ3000-74-2A-L6 SZ3000-74-2A-L8 4(A), 2(B) port 1(P), 3(R) port Other Tube Brands Caution 1.
VP300-27-1A VP500-27-1A VP700-27-1A Series VPA342 VPA542 VPA742 Bracket (With screw) Only VPA344, VPA544 and VPA744 Specifications Fluid Type of actuation Air N.C. or N.O. (Can be switched.) Note) Standard Vacuum Operating pressure range (MPa) 0.2 to 0.8 N.C.
VA, DC: 15 W Contact point construction: 1a, 1b Maintenance space Float switch Part no.
EVS1001-9-2H Gasket 1 AXT632-25-15 (M4 x 30, with washer, nickel plated) Hexagon bolt 2 EVS1001-9-1 Light cover 3 29.5 x 1.2 O-ring 4 OR-0500-130-H O-ring 5 30 Exploded View of Manifold Manifold block assembly D-side end plate assembly U-side end plate assembly Housing assembly and SI unit EX250 EX600 EX500 EX126 S kit q r e w t @0 i u y @2 !8 o @1 !0 !9 !
100 15 100 Note 1) Apparent power: The value at ambient temperature of 20C and when the rated voltage is applied.
-1 XLD40-30-1 XLD50-30-1 XLD25-30-1H XLD40-30-1H XLD50-30-1H 63 80 100 160 XLD63-30-1 XLD80-30-1 XLD100-30-1 XLD160-30-1 XLD63-30-1H XLD80-30-1H XLD100-30-1H XLD160-30-1H 1) M9// XLD25-30-1-M9// 2) 3) FKM:No.1349-80XLD25-30-1-XN1 4) S / 25 40 50 AS568-030V AS568-035V AS568-039V AS568-030 ** AS568-035 ** AS568-039 ** B2401-V24V B2401-P42V AS568-227V B2401-V24 ** B2401-P42 ** AS568-227
AXT661ALead wire length (mm) 6 43 Blanking plate with connector Connector Connector lead wire length (mm) 43 44 4-wire 2-wire Lead wire color: Black Lead wire color: Red Nil 300 600 1000 2000 3000 Nil 300 20 25 30 2000 6 10 20 30 Nil Without connector With connector/2-wire With connector/4-wire 1 2 6 10 15 600 2500 1000 3000 Lead wire color: White 24AWG 1500 Cover O.D. 1.5 Blanking plate
-30-1-1 XLF80-30-1 XLF80A-30-1 XLF80-30-1H XLF80A-30-1H XLFV80-30-1 XLFV80A-30-1 XLD80-30-1 XLD80-30-1H XLDV80-30-1 XLG80-30-1-1 XLG80-30-1H-1 XLGV80-30-1 63 XLA63-30-1 XLA63A-30-1 XLA63-30-1H XLA63A-30-1H XLAV63-30-1 XLAV63A-30-1 XLC63-30-1-1 XLC63-30-1H-1 XLCV63-30-1-1 XLF63-30-1 XLF63A-30-1 XLF63-30-1H XLF63A-30-1H XLFV63-30-1 XLFV63A-30-1 XLD63-30-1 XLD63-30-1H XLDV63-30-1 XLG63-30-1
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
Facility water temp. 25 1500 Cooling capacity[W] 1500 25 Cooling capacity[W] 32 32 35 35 1000 1000 500 500 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T1 is selected.
(Turn proof structure at pressurized state) 1.17-2 AL1000 to 6000 Standard Specifications AL1000 AL2000 AL3000 AL4000 AL4000-06 AL5000 AL6000 Model 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 M5 X 0.8 Port Size Air 1.5MPa 1.0MPa Fluid Proof pressure Max. operating pressure 1/4: 30 3/8: 40 1/2: 50 130 1/4: 30 3/8: 40 50 Min.operating flow (l/min (ANR))(1) 50 190 220 4 15 130 130 130 7 25