Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models. 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Connector 12 V Yes 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire
Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models. 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Connector 12 V Yes 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire
Indicator Unit (LED) Descriptions and Functions SI unit (DeviceNet) SI unit (PROFIBUS-DP) Input block 1 3 5 7 PWR 0 2 4 6 TM TM PWR(V) RUN PWR(V) MOD/NET PWR ADDRESS 1 H L 0 SETTINGS DIA BF FB FB PS PS Description Description Function Function Description Function PWR(V) ON when solenoid valve power supply is turned ON. ON when sensor power is turned ON.
25 M For positive pressure ZSE30 01 25 M For vacuum/low pressure Option 2 Piping specifications Nil None Bracket R 1/8 (With M5 female thread) 01 NPT 1/8 (With M5 female thread) A T1 Straight type 4 One-touch fitting 5/32" One-touch fiting C4H Output specifications Panel mount 25 65 26 28 NPN output PNP output 1 to 5 V output 4 to 20 mA output C6H 6 One-touch fitting B N7H 1/4" One-touch
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFT04-01 KFT04-02 KFT06-01 KFT06-02 KFT06-03 KFT08U-01 KFT08U-02 KFT08U-03 KFT08N-01 KFT08N-02 KFT08N-03 KFT10U-02 KFT10U-03
Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" AS1002F V V V V V V AS2002F V V V V AS2052F V V V V AS3002F V V V V V V V AS4002F V V V V 1 Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the Web Catalog for details.)
Mounting Screw Tightening Torques M3: 0.8 Nm 4-6-34 35 3 Port Solenoid Valve Rubber Seal, Body Ported/Base Mounted Series VZ500 Manifold for Internal Pilot How to Order Applicable solenoid valve VZ512--01 VZ512M--01 VZ522--01 Z522M--01 Applicable blanking plate assembly DXT201-15-4A Type 20/21 VV3Z5 20 05 1 A port A port P/R port thread type Manifold P port Stations 20 21 Type 20 Type 21
How to Order Manifold [Option] VV5Q 1 08 C6 XP 1 V S 10 CE compliant CE compliant Nil Q Enclosure Note) Refer to SI Unit Part No. when ordering the CE-compliant SI unit.
How to Order Manifold [Option] VV5Q 1 08 C6 XP 1 V S 10 CE compliant CE compliant Nil Q Enclosure Note) Refer to SI Unit Part No. when ordering the CE-compliant SI unit.
Setting of the selected alarm Setting range: AL.01 to AL.51 to 63. Press the [MENU] key once. Returns to the main display (which shows the circulating fluid temperature).
Internal voltage drop: 1 V or less (With load current of 80 mA) PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (With load current of 80 mA) Switch output Note 4) Output specifications NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulse Pulse width: 50 msec Accumulated Note 4) pulse output Output voltage: 1 to 5 V; Load impedance:
I"P.1/4, .. . , ASP530F-N03-11 S 3/S' ~ 25.9 1 51Jtr 11 / 16" 28.6 ~6~5 ~ 61 ;a.: ~:B-.9 :2D.S 220 tU6' /36,3 . 34:7 .26~ 21.7 . . ~ A efertlllCe dll'l'lerlSlons 1 01 NPT Ihmads aller installalion 3 Speed Controller 5 . ASP w"" P;lo' Ch.,k V,'v. efles Construction Parts list .QesCr;plian ' ''' fi1t~lal , . . .
Ordering Example: VV307-01-052-01-F1 pc. (5 station manifolds base) V0307-1G4 pcs. DXT060-51-13A 1 pc.
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 4 Stations, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 8 Stations, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 8 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 9 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 2 Stations, Voltage: 5 (24 VDC)