Hexagon socket head cap screw C (M4 x 5L) Switch mounting rod mounting tap (3 locations) Switch mounting rod mounting tap (3 locations) (Attached to auto switch) Hexagon socket head cap screw A (M2.5 x 11L) Auto switch Hexagon socket head cap screw (M3 tightening torque: 0.5 to 0.7 Nm) Auto switch mounting bracket Plugged Hexagon socket head cap screw B (M4 x 8L) Switch mounting rod E Auto
C 54 56 ZPR10C I 56 ~PRllII ZPR10 ZPR16U 16 18 12.5 21.5 30.4 46.5 57.5 80.5 91.5 3.5 1.2 C Deep type 54 ZPR13 54 54 mml 54 'y o ' O A ~B Ij G 75 ~ 1 2 10 60 83 94 6 76 2; '" ZPR16D 16 18 15 6 5l 61 84 Z ~6 ~O 75 75 ZPR?S 76 76 76 Apphcable tube mm ZPI!~2 ZPR40 128 Q O P R .S 129 128 04 4. 20.6 15.6 10,4 130 .6 ' . 16.6 6 21.6 12.8 Applidal\le lWe 0.0 128 1 30 ZI!J!
In order to hold the locked state, be sure to follow the steps below after confirming safety. 1) Remove the dust cover (1). 2) Supply air pressure of 0.2 MPa or more to the unlocking port (2) shown below and unlock. 3) Screw the attached hexagon socket head cap bolt (3) (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), into the lock ring to hold the unlocked condition. 2.
SP158X-002E P: TS P.G.Information (Specialized Product) SMC Corporation 4-14-1, SOTO-KANDA, CHIYODA-KU, TOKYO 101-0021, JAPAN URL: http://www.smcworld.com Liquid Dispense Pump (Solenoid type) Series LSP Features Compact solenoid type diaphragm pump, which dispenses fixed amount of liquid from 5L to 200L each time it is operated.
Right angle, 5 m Joint bracket ISA-3-A Lead wire with connector (Individual wiring type) ISA-8-A ISA-8-B DIN rail mounting bracket ISA-9-A With mounting screw 2 pcs. 878 A Air Catch Sensor Series ISA2 DIN Rail DIN Rail ISA-5ISA-5L Applicable models L 4.5 8 1.3 7.5 Part no.
Qi '5 0 ~ 5l :r 0. 31<.-t-~-+---="I--;;::'--t-t_1 Q. 0.15 f-t.,---+t--t-+---1--+-t--t-l 8Tightening torque of mounting screw (M3) for gauge is 3-Skgf . cm.
Model: 42 (Dual AC Type), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 5L (ø3/16" Elbow)
(Adjust the bypass valve) AL14 Circulating fluid temperature increase OFF3 AL14 TEMPOUT.HI AL15 Circulating fluid temperature decrease OFF3 AL15 TEMPOUT.LO Displayed flow rate: 5L/min or less(For 400V type options Z and Z1:Less than 7L/min), piping is thin, external valve is closed, pinching or blockage of the piping or clogging of the filter.
25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Approx.2200W(water), 1500W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN HT-135 Fluorinert FC-77, FC-3283) Recirculating fluid Reservoir capacity : Approx.5L
./ 80L/min(ANR)(SUP=0.14MPa) *3 200L/min(ANR)(SUP=0.4MPa) 5L/min(ANR)(SUP=0.14MPa) *3 11L/min(ANR)(SUP=0.4MPa) 2080() 2060( ExdBT5) ExdBT5(TC15916) A A Rc1/4 1/4NPT G1/4 Rc1/8 A G1/2M20X1.51/2NPT G1/2 2.6kg 2.4kg JISF8007 IP65(IEC Pub.529) *11/21/2%F.S.
In order to hold the locked state, be sure to follow the steps below after confirming safety. 1) Remove the dust cover (1). 2) Supply air pressure of 0.2 MPa or more to the unlocking port (2) shown below and unlock. 3) Screw the attached hexagon socket head cap bolt (3) (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), into the lock ring to hold the unlocked condition. 2.
8 Symbol 03 VBA4200-04 Rc(PT)1/2 Related Products Air operated style Model Description Notes VBA1110/1 VBA2100/2200 VBA4100/4200 VBA2200-03 P.4.6-1 AM250-02 AM450-04/06 AM550-06/10 Mist separator AMC310-03 AMC510-06 AMC610-10 35dB or more of noise reduction Exhaust cleaner VBAT20 (20l, Directly connected to booster regulator) VBAT38 (38l, Directly connected to booster regulator) VBAT05 (5l
pressure: 1.0MPa) Exhaust port: 2l/min (ANR) or less (at maximum set pressure) Bleed port: 9.5l/min (ANR) or less (supply pressure: 1.0MPa) Exhaust port: 2l/min (ANR) or less (at maximum set pressure) 4l/min (ANR) or less (supply pressure: 1.0MPa) 3l/min (ANR) or less (supply pressure: 0.7MPa) 4l/min (ANR) or less (supply pressure: 1.0MPa) 3l/min (ANR) or less (supply pressure: 0.7MPa) Note 4) 5l
In order to hold the locked condition, be sure to follow the procedures below after confirming safety. 1) Remove the dust cover . 2) Supply air pressure of 0.2MPa or more to the unlocking port shown below and unlock. 3) Screw in the hexagon socket head cap bolt (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), included, into the lock ring and hold the unlocked condition. 2.
In order to hold the locked condition, be sure to follow the procedures below after confirming safety. 1) Remove the dust cover . 2) Supply air pressure of 0.2MPa or more to the unlocking port shown below and unlock. 3) Screw in the hexagon socket head cap bolt (20, 25: M3 x 0.5 x 5l, 32: M3 x 0.5 x 10l), included, into the lock ring and hold the unlocked condition. 2.
VQ110-5L 4 set Valve part no. (1st to 4th stations) VVQ100-10A-2 1 set Blanking plate part no. (5th stations) Applicable solenoid valve (Plug lead type) VQ10-L VQ10-M VQ10-G 1 VQ100 Series Prefix the asterisk to the part nos. of the solenoid valve, etc.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT VP How to Order Valve Manifold Assembly (Example) VG U side D side 1 3 Stations 2 VP S070 VQZ215-5L 4 sets VQ VV3QZ25-05C6C 1 set (C kit 5 stations manifold base) VVQZ200-10A-51 set (Blanking plate assembly) VQZ215-5L4 sets (N.C. type part no.)
Example) VQ1130-5L-C6-A A port, Plug 2-4-24 25 Body Ported Series VQ1000 Plug-in Unit: Flip Type Double check block (Separated type) VQ1000-FPGIt is used on the outlet side piping to keep the cylinder in the intermediate position for a long time.
U side D side Stations 1 2 3 4 5 VQD1151-5L Port size (Body ported only) M5 thread M5 VQD1000-10A-5 2B 4A 3R 1P 2B 4A VV4QD15-05M5 2-8-8 9 4 Port Direct Operated Poppet Solenoid Valve Series VQD1000 Manifold Option Blanking plate assembly/Body ported VVQD1000-10A-2 VQC Blanking plate assembly includes 2 screws and gasket SQ VQ0 VQ4 Blanking plate assembly/Base mounted VVQD1000-10A-5 VQ5 Courtesy
C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R H O W T O O R D E R S E E N E X T P A G E G A S K E T: N I P P L E: M-3N M-5N U N I V E R S A L T E E: M-3UT M-5UT P L U G: M-3P M-5P M-5G1 M-3G P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R E L B O W: M-5L