11) [opposite side] IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 5 A IDU3E-20, IDU4E-20 IDU6E-20, IDU8E-20, IDU11E-20 [mm] Dimensions Model A B C D E F IDF22E-20 59 40 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 25 46 IDF37E-20 IDF22E-30 39 30 mA 125 10 A 60 60 IDF37E-30 IDF55E-30 148 81 50 36 IDF75E-30 133 73 IDU22E-30 151 74 200 V
This produces an air cushion cylinder which retains the merits of a compact design. Operating principle A + A' A' qWhen the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. wAfter piston seal H has passed the air passage A, exhaust is discharged only from A'.
This is equivalent to a magnetic field of approximately 18 cm in radius from a welding area using a welding amperage of almost 15,000 amperes. To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit.
This is equivalent to a magnetic field of approximately 18 cm in radius from a welding area using a welding amperage of almost 15,000 amperes. To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit.
This is equivalent to a magnetic field of approximately 18 cm in radius from a welding area using a welding amperage of almost 15,000 amperes. To use the system in a magnetic field that exceeds this value, use a magnetic material to shield the sensor unit.
In order to measure with a discrimination of 0.01 mm, a counter with a 4 times multiplication function (CEU5) is required.
L R O D T H R E A D X A O P T I O N Thread Form Code M .
Part no.: RQB32-47 A special tube is manufactured for a 47mm stroke.
L R O D T H R E A D X A O P T I O N Thread Form Code M .
OUT OUT Proper Auto Switch Mounting Positions (Stroke End) Proper Auto Switch Mounting Positions(Series CE1) Auto switch (mm) Bore size (mm) Auto switch model Symbol 20 32 40 50 63 12 A B A B A B A B A B A B A B A B A B 40.5 47 55 79 82 85.5 D-A7, A8 4 13 17 39 44 41.5 41 47.5 55.5 79.5 82.5 86 D-A7lH, A80H, A73C, A80C, D-F7l, J79, F7lV, J79C 4.5 13.5 17.5 39.5 44.5 42 A B 38 44.5 52.5 76.5
This produces an air cushion cylinder which retains the merits of a compact design. Operating principle q When the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. A + A' A' w After piston seal H has passed the air passage A, exhaust is discharged only from A'.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Actuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 2. Effect of back pressure when using a manifold Use caution when valves are used on a manifold, as actuator malfunction due to back-pressure may occur.
Hv Auto Switch Proper Mounting Position Solid state auto switch Bore size (mm) 2-color indication solid state auto switch Reed auto switch B C A B Hv A B C A B Hv A B Hv A B C D-A9 D-A9V D-M9 D-M9V D-F8 D-M9W A B Hv D-M9WV A 36 25 16 36 25 15 32 21 20 32 21 17.5 18 7 25 32 21 20 32 21 17.5 8 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
Port size 01 C4 C6 Rc 1/8 4 cassette 6 cassette Solenoid on opposite A port Nil 1(P) port: Rc 1/8 3(R) port: Rc 1/8 Solenoid on same side as A port 2(A) port: Rc 1/8 S Valve stations Type S42 (Solenoid on same side as port A) 01 1 station 1(P) port: Rc 1/8 3(R) port: Rc 1/8 20 20 stations 2(A) port: Rc 1/8 4-13-7 8 Series VKF300 Dimensions: Manifold Body ported Common SUP, Common EXH/Top
The continuous duty AC type is equipped with a rectifier, so a diode will be provided. Construction Symbol (A)2 (R)3 1(P) Component Parts Material Aluminum die-casted No.
A B Hs A B Hs Hv Hv Hv Hv 12/16/20 12/16/20 Hs Hs 25/32/40 25/32/40 Proper Auto Switch Mounting Position Solid state switch Bore size (mm) 2-color indication solid state switch Reed switch D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV A B C A B Hs Hv A B A B Hs Hv A B C A B Hs Hv C 15.5 15 20 20 15 19.5 19.5 19.5 19.5 46 46 46 46 18 13 15.5 35.5 42 31.5 42 31.5 12 17 17 22 22 17 21 21 21 21 47.5 47.5
tubing T0604 (A port) (A port) Refer to the above drawing for DIN terminal dimensions.
Because tube fittings are provided, use a tube with a bore of 10mm, and keep the overall pipe length within 5m. AM850 type (N.O) Use a tube with a bore of 9mm or more, and keep the overall pipe length within 2.8m.