~~ , A 00) 0(0) 0 (2.5) 2(6) 4(7. 5) ~ , 40 D-AG 43.5 49 55.5 3 D-AS 1(0 1(0) 5(1.5 I O{S.5) 8(4 3t 35 42 so 57 .5 ~ Ht A 00) 00) 0(2.5 26 417 .5) D-A3 B !
x 1.5 NBR O-ring JIS B 2401 P3 JIS B 2401 P4 JIS B 2401 P5 NBR O-ring (1) (1) (1) P36203015 NBR Seal (A) P36203016 NBR Seal (B) KT-IRV1000 KT-IRV2000 KT-IRV3000 Repair kit no.
(R) 1 (P) 1 (P) 25 17 2 4-Rc1/4, 3/8, 1/2 4-Rc3/4 VH43l-02 to 04 (Bottom piping) VH43l-06 (Bottom piping) 2 (A) 2 (A) 46 54 1 (P) 3 (R) 1 (P) 3 (R) 4 (B) 4 (B) 4-Rc3/4 4-Rc1/4, 3/8, 1/2 3.6-13 Hand Valve Series VH Precautions Be sure to read before handling.
Indication Item Setting and selection *1 A contact (normally open) Contact type B contact (normally closed) *1 Alternate Signal form (1) Input 1 Contact input signal 1 Momentary [Off] Disabled [External Switch] External switch signal Signal type [Run/Stop] *1 Run/stop signal [Run] *2 Run signal *1 A contact (normally open) Contact type B contact (normally closed) *1 Alternate (2) Input 2
Bit offset Item Notes 0 CH1: OUT1 output 0: OFF 1: ON 1 CH1: OUT2 output 0: OFF 1: ON 2 CH2: OUT1 output 0: OFF 1: ON 3 CH2: OUT2 output 0: OFF 1: ON 4 CH3: OUT1 output 0: OFF 1: ON 5 CH3: OUT2 output 0: OFF 1: ON 6 CH4: OUT1 output 0: OFF 1: ON 7 CH4: OUT2 output 0: OFF 1: ON 8 CH1: Diagnostics 0: OFF 1: ON Out of CH1 display range (When HHH and LLL are displayed). 9 CH2: Diagnostics 0:
I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10 15.5 1.5 1.6 13 23 14 25 36 16 25 37 16 24 36 32 40 65 31 39 64
06 10 1/4 01 02 03 04 06 10 1/8 3/8 1/4 1/2 3/8 3/4 1/2 1 3/4 Option Note 1) 1 Symbol Nil B G Note 2) Applicable model AR25 to 60 AR25 to 60 AR25 to 40 Description With bracket With round pressure gauge (with limit indicator) With set nut (for panel mount) Option Note 1) Symbol Nil B G Note 2) Applicable model AR20 to 60 AR20 to 60 AR20 to 40 Description With bracket With round pressure
M5 Port size M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Type 01 02 03 04 U10/32 N01 N02 N03 N04 Elbow Universal 2 3 Universal type Applicable tubing O.D.
FGDCA/B FGDEA/B FGDTA/B FGDFA/B (Rc) 3/81/23/4 (MPa) 1) 0.7 1.0 ( oC) 80 FGD*A:1 FGD*B:2 2) (mm ) FGD*A:6570250 FGD*B:6570500(2 :6570250) (MPa) 0.1 SCS14 SPCE SUS316 /O NBR () () 4) (kg) FGDCA/FGDEA:1.3 FGDCB/FGDEB:2.2 FGDTA/FGDFA:2.3 FGDTB/FGDFB:3.8 (L) FGD*A:1.7 FGD*B:3.4 1) 0.5MPa 2) (65500mm) 3) 4) 3. 001 -B FGD C A 03 B N 1 * -B * * A L250 B L500(L2502 ) 03 3/8 04
01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) 04 4 06 6 08 8 10 10 12 12 With One-touch fittings Example) AS2002F-04A-X214 10Clean Series Example) 10-AS2002F-04A 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing. *1 Fluorine grease is used. *2 The cleanliness class (ISO class) is 5.
3 8 KGE10-03 3 8 KGE12-03 37 14 92 59 12 M22 1 27 24 23 22 58.3 46.1 1 2 KGE12-04 41 18 3 8 KGE16-03 14 40 127 25 96 113 (96) 16 M28 1.5 32 29 30 1 2 KGE16-04 18 44 132 Note) ( ): Values for soft nylon.
Applicable Body Size All All 31, 41 31, 41 Symbol Nil B* C D Port Size 1/4 3/8 1/2 *Note: Bracket is not assembled and is supplied loose at time of shipment.
Applicable Body Size All All 31, 41 31, 41 Symbol Nil B* C D Port Size 1/4 3/8 1/2 *Note: Bracket is not assembled and is supplied loose at time of shipment.
-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4
button: White color) 2, 3.2, 4, 6, 8, 10, 12 Inch size (Release button: Orange color) 1/8", 5/32", 3/16", 1/4", 5/16", 3/8", 1/2" AS321F-02 AS331F-02 R1/4 AS321F-03 AS331F-03 R3/8 AS421F-04 AS431F-04 R1/2 Note 1) AS121F-M5-02 applicable cylinder bore sizes are 2.5, 4, 6.
NPT thread Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32 1/4 5/16 3/8 1/2 From One-touch fitting to male thread B Bushing type AKB 01 A 01 S With seal (Standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction Female/Male
EX) Base: 6 stations, common EXH, A & B port Rc 1/2 VVPA450-061-04 1 pc. VPA4154-00 3 pcs. VPA4254-00 2 pcs. XT038N-4A 1 pc.
Type Metric size Inch size Elbow Universal 2 3 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 23 3.2 4 6 8 10 12 03 05 07 09 11 13 04 06 08 10 12 Control type Meter-out Meter-in 0 1 Use 1/8" tube.
Note 1) Body size AS-F AS-F With indicator Metric size Inch size 2 1/8, 1/4 3 3/8 4 1/2 Type Tubing O.D. 23 3.2 Note 2) Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" TMH 2 Elbow 04 4 06 6 08 8 10 10 12 12 16 16 ASD Control type Note) AS 0 Meter-out 1 Meter-in Indicator window direction AS-FE Note) Meter-out and meter-in types can be visually identified by color of the knob
(With 2 input blocks) With External Pilot Specifications 46.5 (Pitch) 2-M12 M3 16.5 18.3 13.5 P = 10.5 14.1 8.4 SV 8.6 10 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 17.7 24.6 23 59.5 SZ 3 3 PWR 3 3 42.7 5 3 E 3 5 E 5 3 E 3 5 E T T 43 PWR 56.5 2 2 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 1 P 1 P 1 P 1 P One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 8 5/16" 1 1 1 1 BUS 4632