SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20CF-V-02-WA1"

V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 195 Thermo-chiller Basic Type HRSE Series

0.35 (With light: 0.4 (DIN terminal with light: 0.45)) 1 (P) 3 (R) 1 (P) 3 (R) Power consumption (W) DC 0.1 (With light only) External pilot 1.4 (With light: 1.5) 100 V 110 V [115 V] 200 V SYJ51 R 2 4 SYJ52 R 2 4 1.6 (With light: 1.7) [1.7 (With light: 1.8)] (A) 2 (A) 2 Apparent power (VA) AC X X 2.3 (With light: 2.4) 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 220 V [230 V] 1 (P) 3 (R

Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator

A DB BN BP BO DC eO eE F GA GB GC GO 10011500 50 136 Bore Size Stroke r.naecmm) (mm) WHhoot boot WHh boot GL GR J K MM 27 30 60 96 V V 44 16 32 10 as 15 26 54 40 500 20500 50 600 20-600 10 10 M8X1 .25 6 M14X1.5 32 35 70 108 V 'I, 52 20 40 10 95 17 27 59 32 35 86 11 5 V V 64 20 40 10 102 17 , 26 67 13 12 M8X1.25 7 M18X1.5 63 600 20-600 18 15 M10X1 .25 7 M18X 1.5 37 40 102 129 V V 78 25 52

P PNP Max.80 mA 1 V -S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -17No.PS-OMM0002CN-F -V/-T () PNP 2 Max.80 mA 1 V T15 V 1 k V420 mA 12 V 300 24 V 600 50 -V/-T () PNP 2 Max.80 mA 1 V -A NPN2 Max.28 V80 mA 1 V -B PNP2 Max.80 mA 1 V -18No.PS-OMM0002CN-F ONOFF () ON OFF ON5OFF 20 P 1 H_1 [Pa] ON OFF [s] -19No.PS-OMM0002CN-F

Type V regulator (AR) is modified to produce the micro mist separator regulator (AWD).

To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.

Float type auto drain AD44 Pressure gauge (V type only) Case assembly (N.O.)

Relay, PLC 100 V Reed switch Solid state switch PLC 100 V, 200 V Relay, PLC 12 V Yes Yes 24 V 2-wire Terminal conduit PLC 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V 24 V IC circuit Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC 12 V 3-wire (NPN

OFF: Solenoid valve power supply voltage is less than 19 V. PW(V) ON: Normal traffic OFF: Traffic disconnected (Timeover error) L RUN ON: Traffic error BLINKING: Station or baud rate switch is set while the power supply is ON. OFF: Normal traffic L ERR When the data link is normal, PW, PW (V) and L RUN are ON.

Solenord side. .9 fi V f--'.--ry] f+r-q | r + r i | | t-?-!+-<-{ l r l tF)-)-+++--(lr{ I , _ ' I{ANIFOLD BLOCK PART NO. NO. PRESSURE CYLII{OEF " A & 8 " EXHAUST "EA & E8" SIDE aoTTor !OYTOT MSA 1010.02 Yes '/f t2) Yes MBA 10't r.02 11 Yes 't"et t ' l Z YE MAA 4210.02 t6 Y5 v." 11) v.' t2\ t " t2:l t ' l a STATX)flS 2 3 a 5 6 7 I t t0 -1 nm) 5 .

02 Pressure center VFS2510-E-01 02 DIN terminal: Double VFS2210-D Y-01 02 Closed center VFS2310-D Y-01 02 Exhaust center VFS2410-D Y-01 02 Pressure center VFS2510-D Y-01 02 EVS VFN With light/surge voltage suppressor Lead wire O.D.

O.D. 4 2.5 1 4 1 4 3 8 KFF04-02 KFF06-02 KFF06-03 KFF08U-02 KFF08N-02 KFF10U-02 KFF10N-02 KFF12U-02 KFF12N-02 10 33.5 26.8 15 15 17 1.6 25 27 30 17 17 19 15.5 1.5 33.2 26.5 6 15.2 3 12 6 4 35.2 28.5 5 6 11 17 21 30 35 45 4 5 5.5 6.5 7 8 Connection thread Applicable tubing 14 17 1 4 33.2 26.5 15 16.2 28 8 10 6.5 7.5 1 4 32 17 17 34.8 27.5 15 18.8 12 8 9 35 36 1 4 19 17 35.3 28.5 15 19.3 15

TI/ TIL Table (2) Rated Voltage-Electrical Entry-Electrical Option Table (1) Connection Size and Applicable Model PA Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G Connection Applicable model VXD2130-02 VXD2130-03, VXD2140-03 VXD2130-04, VXD2140-04 VXD2150-06 VXD2260-10 VXD2270-32 VXD2380-40

Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Connector Terminal conduit DIN terminal Grommet 12 V 2-wire 24 V PLC Relay, PLC 100 V, 200 V Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC Yes 24 V 12 V 3-wire (NPN) 3-wire (PNP)

Common IN Individual IN Common IN Individual IN Bonnet Polyacetal w o ARM2500 -A-02 ARM2500 -B-02 ARM3000 -A-03 ARM3000 -B-03 1 Regulator Regulator Replacement Parts 1 1 1 End plate R End plate L O-ring !0 !1 !2 Description Material Part no. No.

Common IN Individual IN Common IN Individual IN Bonnet Polyacetal w o ARM2500 -A-02 ARM2500 -B-02 ARM3000 -A-03 ARM3000 -B-03 1 Regulator Regulator Replacement Parts 1 1 1 End plate R End plate L O-ring !0 !1 !2 Description Material Part no. No.

Note 2) Value on option V (Non-leak, Vacuum).

) 4 AC 200 V 2.3 (With light: 2.4) 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 220 V [230 V] 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) Surge voltage suppressor Diode (Non-polarity type: valistor) 3 position exhaust center 3 position exhaust center (B) 2 (A) 4 (B) 2 (A) 4 Indicator light LED In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.

circuit 0.35 (With light: 0.4) Power consumption (W) DC 0.1 (With light only) External pilot 1.4 (With light: 1.5) 100 V 110 V [115 V] 200 V SYJ31 R 2 4 SYJ32 R 2 4 1.6 (With light: 1.7) [1.7 (With light: 1.8)] (A) 2 (A) 2 Apparent power (VA) AC X X 2.3 (With light: 2.4) 220 V [230 V] 2.5 (With light: 2.6) [2.7 (With light: 2.8)] 1 (P) 3 (R) 1 (P) 3 (R) Surge voltage suppressor Indicator