bracket 20Set screw (M4) Data Mounting bracket (b) Tie-rod Auto switch mounting screw (With hexagon socket head) M5 x 0.8 Auto switch Bracket set screw M5 x 0.8 x 12 l Mounting bracket (A) 1.
bracket 20Set screw (M4) Data Mounting bracket (b) Tie-rod Auto switch mounting screw (With hexagon socket head) M5 x 0.8 Auto switch Bracket set screw M5 x 0.8 x 12 l Mounting bracket (A) 1.
bracket 20Set screw (M4) Data Mounting bracket (b) Tie-rod Auto switch mounting screw (With hexagon socket head) M5 x 0.8 Auto switch Bracket set screw M5 x 0.8 x 12 l Mounting bracket (A) 1.
x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 12 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through
bracket -X Set screw (M4) 20Mounting bracket (b) Tie-rod Data Auto switch mounting screw (With hexagon socket head) M5 x 0.8 Auto switch Bracket set screw M5 x 0.8 x 12 l Mounting bracket (A) 1.
A A A-A r q e w A A-A e r q w Component Parts No.
M5 thread With 3.2 One-touch fittings With 4 One-touch fittings With 6 One-touch fittings M5 thread 2(B) (A)4 Side ported 5 (R1)5 1 (P) 3(R2) Note) For double solenoid specification, the function symbol below is D.
A scraper is not installed. A separate version -X324 (with a felt dust seal) is available in cases in which dust, etc. is dispersed throughout the environment. Mounting taps have been added on the surface opposite the standard positions.
port CEP1 C + Stroke B + Stroke A + Stroke M5 x 0.8 R port CE1 CE2 [ ]: Denotes AC.
Fluororubber is used for rubber seal materials. 80 IR 0 Ozone resistant X170 IR 0 Compatible with modular connection brackets Modular Combination Example Description Applicable model IR100--X170 AF20-A AFM20-A Y200-A Y200T-A IR20--X170 AF30-A AFM30-A Y300-A Y300T-A IR30--X170 AF40-A AFM40-A Y400-A Y400T-A qRegulator wAir filter eMist separator rInterface tInterface with bracket Note 1) The
Symmetric mounting Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
The plug (M5 x 0.8) in the standard dimensions becomes a relief port. Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
The plug (M5 x 0.8) in the standard dimensions becomes a relief port. Relief port size M5 x 0.8 Piston speed 50 to 400 mm/s Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.
Applicable bore (mm) d H1 B1 C1 4T counterbore A' 6 10 16 20 25 32 NTP-006 NTP-010 NTJ-015A NT-015A NT-02 NT-03 M3 x 0.5 1.8 2.4 4 5 5 6 5.5 7 8 10 13 17 6.4 8.1 9.2 11.5 15.0 19.6 S + Stroke Auto switch M4 x 0.7 Z + Stroke M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 Bore size (mm) A A' B C D E GA GB H J K L MM NN P Q QA 6 10 16 20 25 32 7 10 11 12 15.5 19.5 10 10 11.5 12.5 13 12.5 12.5 14 18
After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn for a port size of M3 x 0.5 or 1/6 turn for a port size of M5 x 0.8. For elbow type fittings, tighten an additional 1/2 turn for a port size of M3 x 0.5 or 1/3 turn for a port size of M5 x 0.8 if gaskets are mounted in two places.
x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 12 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through
hole & Double end tapped): MQQTB 10, 16, 20 H effective thread depth C 2-M5 x 0.8 2 x 4-OA effective depth RA 2 x 4-OB Depth of counterbore RB F Q Y I 4-N through 0.2 D E M L B + Stroke K 0.2 A + Stroke M E 25, 30, 40 H effective thread depth C 2-Rc1/8 (NPT1/8, G1/8) F Q Y 2 x 4-OB Depth of counterbore RB 2 x 4-OA effective depth RA J I 4-N through 0.2 D W E M K L B + Stroke 0.2 A + Stroke
L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420
This product should not be used as a stopper.