SMC Corporation of America
Elite Part Number Search
Search Results "11-CDM2XB32-150"

Right angle type cable connector 3 m 52 10 ARJ (33) Straight type cable connector 3 m AR425 to 935 52 12.5 ARX AMR Setting part ARM 10 M12 x 1 Cable connection thread (Plug type) 5.5 8 ARP 111 11 Digital pressure display IR-A M5 x 0.8 Solenoid valve EXH Breathing IR M4 x 0.7 depth 8 F.G.

CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.

Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 4, 6, 10 and 11. 100% (Extended side) Note) Thrust 0% (Retracted side) Note) 100% Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 4, 6, 10 and 11. 23 Directional Control Driver Precautions 1 Be sure to read this before handling.

D2 Blue () COM 14-11-18 Digital Pressure Sensor Series GS40 Dimensions 14 10 F.R.L. Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type PT type 40 VBA VE SMC DIGITAL PRESSURE SENSOR ALM. SET 20 VY1 + G P.SET PPA AL 14-11-19

ITVH N Bracket dimensions With auto drain Model Port size A M L K J H G F E D C B L 178 211 277 321 B 260 298 366 436 T 9 9 11 11 S 8 16 21 26 R 78 97 98 115 P 50 35 45 46.5 U (Body) V (Adapter) 1 4, 3 8 1 4, 3 8 AMR3000 AMR4000 AMR5000 AMR6000 144 166 188 230 182 215 281 325 21.5 18 16 18.5 37 37 42 42 3.2 3.2 4.5 4.5 32 40 48 56 28 37 37 44 51 61 66 81 101 121 131 161 10 10 45 70 260 302

Material Valve 9 143145 NBR/Brass Spring 10 143146 Stainless steel Valve 8 NBR 14283 143022 O-ring 11 143147 NBR Spring 9 Stainless steel 14282 143023 Cross-recessed head cap screw 12 Note) AA00241 Steel wire Cross-recessed head cap screw 10 AA00241 AA00058 O-ring 11 14284 NBR 143021 Note) AS2000E: Stainless steel, AS3000E: Steel wire. 663 ASE Series Dimensions AS2000E/3000E 2 x port size

Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.

Description Material Note 9 10 11 12 O-ring Body Needle Lock nut Nipple Zinc alloy Stainless steel Steel Note) NBR Brass Brass Steel Needle guide Electroless nickel plated Electroless nickel plated Handle E type snap ring Stainless steel Note) Option: The round lock nut is made of electroless nickel plated brass. Replacement Parts No.

0 P1(11) port u R(4) Exhaust port r !5 o !7 A(2) port P2(12) port w !2 !6 !4 !

11 Symbol B A (A) 4 (B) 2 2 x Rc1/8 (Port 2, 4) 38.2 26.2 2 x M5 x 0.8 (Port 3, 5) 12 14 Rc1/8 (Port 1) 3 (EB) 1 (P) 5 (EA) Total Travel (T.T.) 2.5 Full Operating Force (Reference value)(F.O.F.) 55 N (at 0.5 MPa) 530.2 1590.2 Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.

Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. Caution If a positive pressure is applied to the switch, such as a vacuum break, the output will turn ON (illuminating the indicator light).

Piping diameter ZU05mA 0.5 90 48 7 13 14 3.9 18.6 ZU07mA 0.7 11 16 28 4.3 19.1 The piping diameter for each port should be the standard size of One-touch fitting.

CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.

AM Misc. 14-18-11 12 Series IDUS/IDFS Specific Product Precautions 2 Be sure to read before handling. Protection Circuit Time Delay for Restarting Caution Caution When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. Allow at least three minutes before restarting the dryer.

As a rough guide, tighten the screw an additional 90C after feeling a tight resistance. 4.3-11 Lever Detection Switch (Proximity Switch) Mounting Position Proximity Switch Specifications/Manufacturer: OMRON Co. Ltd. E2E-X1C1 E2E-X2D1-N Model no.

How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15, Closed Dimension L2(mm): 11, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 11, Gripping Force (Open Side at 0.5 Mpa)(N): 11, Environment, Applications: Dust Resistant / Drip-Proof, Additional Function

How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15, Closed Dimension L2(mm): 11, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 11, Gripping Force (Open Side at 0.5 Mpa)(N): 11, Environment, Applications: Dust Resistant / Drip-Proof, Additional Function

(B contact) 2 pcs. 1 R Axial entry Right entry 200/230VAC (50/60Hz) 2 Y 0 Without motor Bottom entry Specifications Intermediate strokes 100 5.1 200 5.9 300 6.7 400 7.4 500 8.2 5 to 40 (with no condensation) 5 150 600 mm kg C kg N mm/s mm Standard stroke Strokes other than the standard strokes on the left are available by special order. Consult P/A.