Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure
], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type), Manifold Individual Supply: w/o Option, Manifold Common Release Pressure Supply: w/o Option, Exhaust Interference Prevention Valve: W (With Exhaust Interference Prevention Valve
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor
Rated Pressure Range: -0.1 to 1 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Motor output [W]/Size [mm] 750/80 Motor type AC servo motor200 VAC Encoder Absolute 22-bit encoderResolution4194304 p/rev Horizontal 135 Power consumption [W] *7 Vertical 150 Horizontal 15 Stnadby power consumption when operating [W] *8 Vertical 45 power [W] *9 Max.1100 Type *10 Non-magnetizing lock specifications 24 VDC Rated voltage [V] Power consumption at at20 [W] *11 Holding force [N
Printed in Japan. 1st printing May, 2002 D-DAD P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)
), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included), Option: B (Adapter Assembly for Bottom Mounting
), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included)