Note 5) Refer to cautions on page 9 if IZN10E-11-(Female threads for piping) is used.
Air and oil are adjusted with varying quantities by the air for mist from the mixing valve (9) and oil adjustment needles (10) and (11).
9 IL220 KT-IL220 Set of left nos. u, i, !1, !2, !4, !5, !
size 1/2 Port size EXH EXH 66 803 IR1000-A/2000-A/3000-A Series Dimensions Basic type (Knob): IR30l1 2-0ll-A 12.5 76 2.3 Bracket (Option) Bracket 48 76 Mounting hole for hexagon panel nut 48 Max. 4 Pressure gauge (Option) Panel 60 46 10.8 9 53 48 68.5 16 M12 x 1 Mounting hole 2.3 M28 x 1.5 9 9 BLEED 2 x 1/8 Pressure gauge port 141 43 91.7 76.1 65.3 22 48.1 EXH OUT IN 2 x 1/4 to 1/2 Port size
Plug: Without check valve Socket: Without check valve KKA4S-02M-1 KKA4P-02M-1 40.2 KKA KKA KKA6S-04M-1 KKA6P-04M-1 76.0 KP How to Order LQ KKA 4 P M 02 MQR Built-in check valve Body size With check valve Nil -1 Socket/Plug designation 1/8 1/4 1/2 3/4 1 1 1/4 3 4 6 7 8 9 T Without check valve P S Plug Socket Note) KKA7/8/9 is not available without a check valve.
Co., Ltd.: NJC-245-PF UL CSA Female connector 1 2 3 4 5 Female connector 6 7 8 9 Alarm output connector D-sub 9 pin (male type) M Communication connector Hirose Electric Co., Ltd.: CDE-9S Holding screw M2.6 Fitting connector: CDE-9P or equivalent Pin No.
JFA connector J4000 series SC02B-J42SK-GHXR 2 24 VDC (1000) 1 RS-485 BUS + 2 RS-232C RD 1 2 3 4 5 3 RS-232C SD 4 RUN/STOP signal input Alarm, RUN/STOP , Communication connector 5 SG 6 Output cutoff alarm (open when alarm occurs) 9 8 7 6 7 Common for output cutoff alarm D-sub 9 pin (socket type) Holding screw: M2.6 8 RUN/STOP signal input 9 RS-485 BUS 8 HEF Series Operation Display Panel
(Wire diameter 0.4 [9 to 11mm]) 10.2 [258] 3.0 [77] 6.2 [158] 1.7 [43] IDFB15E IDFB22E to 75E IDFB15E_Terminal block Signal cable outlet (Wire diameter 0.7 [17 mm]) Grommet with membrane Terminal block Terminal block C A Power cable outlet 0.7 [17 mm] (Wire diameter 0.4 [9 to 11mm]) Power cable outlet 0.7 [17 mm] (Wire diameter 0.4 [9 to 11 mm]) B A D IDFB22E_Terminal block D Dimensions Unit
Note 9) With lock only Note 10) For an actuator with lock, add the power consumption for the lock.
Electrical Entry TT Hazardous Location Class I, II, III Division 1 Groups A, B, C, D, E, F, G Electrical Entry L and LL Hazardous Location Class I Division 1 Groups A, B, C, D Single Unit Warning Do not install in Zone 0 (as defined in IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009)(Refer to page 40 for details) How to Order SY 53 20 01 5 1 LL 3 Bracket UL/CSA compliant 5 7 9
Please contact SMC. 8) Handle must be pulled to turn open from closed. 9) Refer to the specification for options.
Operating Parameters Status Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in
Material Note PBT PBT Description Body A Body B Needle Seat ring Spring U seal Cassette Seal O-ring O-ring O-ring O-ring Gasket 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Body A Elbow body Body B Needle Seat ring Spring U seal Cassette Seal O-ring O-ring O-ring O-ring O-ring Electroless nickel plated Electroless nickel plated Electroless nickel plated Brass
AS-14AB 5 147 2 AS-15AB 7 191 2 AS-16AB 9 236 2 AS-17AB AS-25A Threaded stud kit for manifold AS-9AB 1 set (Adapter for manifold mounting is included.) 3 111 2 AS-24AB 3 119 2 AS-19AB 5 179 2 AS-20AB 7 236 2 AS-21AB 9 258 2 AS-22AB 9 277 2 AS-25AB 9 293 2 AS-43B r Threaded stud kit for manifold AS-30A M4 4 M4 4 Adapter for manifold mounting 119 2 AS-45B 179 2 AS-47B 236 2 AS-48B 277 2 e L-bracket
Clamping block Fulcrum L Bore size: 50 Bore size: 63 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 300 10 9 8 7 6 5 4 3 2 1 0 50 100 150 200 250 300 Allowable load mass [kg] Allowable load mass [kg] 15 15 105 30 30, 45, 60 105 90 120 120 75 90 45, 60 75 Arm opening angle: 135 Arm opening angle: 135 Distance to the center of gravity [mm] Distance to the center of gravity [mm] Bore
9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 Note 1) Threaded through hole is used for the standard of 20 with 5 to 10 mm strokes and 25 with a 5 mm stroke.
Pressure gauge (Option) G46-10-01 VBA VBAT AP100 Applicable cable O.D. 4 to 6.5 1/4 external pilot port AN210-02 Silencer (Option) 1/4 Pilot EXH port 2 x 9 Mounting hole Bracket (Option) VEX5-32A Hexagon socket head cap screw M6 L = 10 (2 pcs.)
9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 Note 1) Threaded through hole is used for the standard of 20 with 5 to 10 mm strokes and 25 with a 5 mm stroke.
SMC's LECS series is an AC servo motor controller, available in incremental or absolute encoder compatible types. The LECSA is a pulse input, positioning type for an incremental encoder, and the LECSB is a pulse input type for an absolute encoder. Also available in the series are the LECSC, CC-Link direct input type for an absolute encoder, and the LECSS, SSCNETlll type for an absolute