SMC Corporation of America
Elite Part Number Search
Search Results "LECSN2-T9-9"

Plug Round type pressure gauge Digital pressure switch Part name Tools Tool size [mm] Recommended torque [N-m] Plug Hexagon wrench key 4 0.55 to 0.65 Round type pressure gauge Wrench 10 7 to 9 Digital pressure switch Wrench 12 7 to 9 -9- Panel mounting 1.

(Rear pressure gauge connection port) Regulator (Front pressure gauge connection port) Plug Round type pressure gauge Digital pressure switch Part name Tools Tool size [mm] Recommended torque [N-m] Plug Hexagon wrench key 4 0.55 to 0.65 Round type pressure gauge Wrench 12 7 to 9 Digital pressure switch Wrench 12 7 to 9 -10- Panel mounting 1.

No.EX-OME0014-F PRODUCT NAME Fieldbus system (SI unit PROFIBUS DP compatible) MODEL / Series / Product Number EX250-SPR1 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product Parts 8 Mounting and Installation 9 Installation 9 Wiring 10 Setting 15 Troubleshooting 22 Specification 28 Specifications 28 Dimensions 29 -1No.EX-OME0014-F Safety Instructions

Trouble Shooting 26 9. Disassembly Drawing 27 10. Dimensions 28~33 -1- These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

This product process data consists of switch output status and position measurement value Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Description 1 Position measurement value (PD) BDC4 BDC3 BDC2 BDC1 1: BDC = Binary Data Channel The process data of this product is Big-Endian type.

(In the case of external pilot specification) (15) Higher voltage or wrong coil used Burnt coil (9) Coil splashed by water (10) Air leaks through EXH. port [3(EB), 5(EA) port] of main valve.

How to Order 9 5. Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12.

Setting 9 Function Hold ON Hold the output pressure Clear OFF Exhaust the output pressure When switching off the power supply to ITV in the communication, output pressure is maintained. The condition that the communication begins from power supply re-investing time depends on the setting of dip switch No.9. Setting of dip switch This switch is selected to dip switch enable or disable.

If it used in an environment where there is possible contact with oil, weld spatter, etc., exercise preventive measures. 9. When the solenoid valve is mounted in a control panel or its energized for a long time, make sure ambient temperatures is within the specification of the valve. Air Supply 3.

Allowable Kinetic Energy 3 9. Precautions on Selection 4 10. Precautions on Design 4 11. Mounting Methods 5 12. Piping 7 13. Operating Environment 8 14. Speed Control 8 15. Troubleshooting 9 16. How to exchange seals 10 17. Construction 12 18. Auto Switch 14 Series MGQ Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

(Rear pressure gauge connection port) Regulator (Front pressure gauge connection port) Plug Round type pressure gauge Digital pressure switch Part name Tools Tool size [mm] Recommended torque [N-m] Plug Hexagon wrench key 4 0.55 to 0.65 Round type pressure gauge Wrench 12 7 to 9 Digital pressure switch Wrench 12 7 to 9 -10- Panel mounting 1.

Warning Caution Rc1/8 7 to 9 Rc1/4 12 to 14 Rc3/8 22 to 24 Rc1/2 28 to 30 Rc3/4 28 to 30 Rc1 36 to 38 Rc1 1/4 40 to 42 Operating Precautions 1. Valves will reach high temperatures from high temperature fluids. Use caution, as there is a danger of being burned if a valve is touched directly. 2.

. -13No.PS-OML0003-J Mounting and Installation Installation Mounting with bracket : The required tightening torque of the piping port is 7 to 9 Nm. The required tightening torque of the mounting bracket screws is 0.5 to 0.7 Nm. Fix the bracket to the Pressure switch with the set screws M35 L (2 pcs) supplied.

When turning over Impact load Clearance Clearance Good: With clearance Not good: No clearance Flipped over Impact load Clearance 9 - 3. Adjust the gripping point so that an excessive force will not be applied to the fingers when inserting a workpiece. Confirm that the gripper can operate without receiving any shock by testing it in manual operation mode or by low speed operation. 4.

(It is possible to blow the poppet valve.) (7) Install a tank on the supply side to stabilize the supply pressure. (8) Install a tank on the pilot pressure supply side to stabilize the pilot pressure. (9) Connect wires correctly. (10) Replace the part. (11) Replace the part or connect wires correctly.

40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.

Aluminum alloy Aluminum alloy Magnetic material Carbon steel Urethane Urethane Carbon steel Brass NBR NBR NBR Carbon steel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Note) The MXH series cannot be disassembled.

Dust-tight 91-Series 92-MSQB Series Material restriction + Lub-retainer + Heavy-duty scraper Dustproofing has been improved with a lub-retainer and heavy-duty scraper. 91--XC4 Series Compatible with main products to terminal devices C-E08-6A 1 2 3 4 5 6 7 8 9 0 Secondary battery manufacturing process Secondary battery manufacturing process Electrode production Environment Copper-free (prohibited

24 5 19 14.5 11.5 15 10 5 25 19 M22 X 1.5 20.5 4.5 17.5 15 31.5 27 24 Panel Mounting Style CJPB B C E G H K MM NN 5st 10st F 15st R 5st 10st S 15st W Q 5st 10st Z Bore (mm) 6 10 15 A 15st 7 12 13.9 6 12.5 19.5 26.5 8.5 9 3.5 M3 X 0.5 M10 X 1.0 9 18.5 25.5 32.5 3 27.5 34.5 41.5 3 10 19 22 6 14.5 21 28 12 12 3.5 M4 X 0.7 M15 X 1.5 13 20.5 27 34 4 32.5 39 46 5 12 27 31 7 16.5 22.5 29 19 14

Description Material Part no. t y u i 1429138 142964 9 x 7 x 1 M-5G1 Valve seat U seal O-ring Gasket Brass HNBR NBR PVC 15-9-29 3 Series AS Construction: AS2000/3000 Component Parts No. Description Model AS2000 AS3000 Aluminum alloy Brass Carbon steel Body Needle Zinc alloy Brass Brass q w r Lock nut Replacement Parts No.