SMC Corporation of America
Elite Part Number Search
Search Results "ISE10-01-B-P"

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes), Flow Direction: R (Right to Left)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes), Flow Direction: R (Right to Left)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: N (w/o Lead Wire and M12 Connector)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Connector Type: S (M12 connector type)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Connector Type: S (M12 connector type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Connector Type: S (M12 connector type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8)

Stations: 01, Systems, Port Combinations: A [Ejector System, ø8 (Common PV)], Exhaust: 1 (Complex Exhaust), Wiring: P (Flat Ribbon Cable Connector), Bracket: w/o Option, Common Release Pressure Supply: D [w/Common Release Pressure Supply (PD) Port], Manifold Individual Supply: w/o Option

Stations: 01, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: 1 (Complex Exhaust), Wiring: P (Flat Ribbon Cable Connector), Bracket: w/o Option, Common Release Pressure Supply: w/o Option, Manifold Individual Supply: w/o Option

Stations: 01, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: 1 (Complex Exhaust), Wiring: P (Flat Ribbon Cable Connector), Bracket: w/o Option, Common Release Pressure Supply: D [w/Common Release Pressure Supply (PD) Port], Manifold Individual Supply: w/o Option