F: Contents are added. [July 2016] G: Contents revised in several places. [August 2019] H: Modified errors in text. [ November 2019] I: Contents revised in several places.

Resistance to ground should be 100 ohms or less. -16No.EX-OMN0009-G LED Indication and Settings LED indication LED Description SF System fault BF BUS fault PWR Turns ON in green when SI unit operating voltage is supplied Turns ON in green when load voltage for the valve is supplied.

(Page 14) F: Limited warranty and Disclaimer are added. G: Contents revised in several places.

.(=0) 100%F.S. a EX.) To set pressure at 0.3MPa by ITV2030( for 0.5MPa type) (0.3MPa / 0.5MPa)1023614 A pressure of 0.3MPa is set by sending input data of SET 614 to the electro-pneumatic regulator through the master PLC. Set pressure F. S. Set dat a Pressure 100% 75% 50% 25% 0% 0 256 512 767 1023 Input data 7 - Communication protocol The character-code used to communicate is ASCII.

MHT2-32D L = 100 mm Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) MHZ Pressure 0.6 MPa MHF 0.4 MPa 0.2 MPa L Gripping point distance (mm) MHL Opening/Closing angle (Both sides) MHR MHT2-40D L = 120 mm MHK MHS MHC Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F , which is the thrust of one

Applicable cylinder bore size (mm) AS121-M5 Model Port size 4 6 8 10 12 M5 x 0.8 6, 10, 16, 20 Construction 1 8 AS221-01 R 20, 25, 32 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R 40, 50, 63 1 2 AS421-04 R 63, 80, 100 Note) marking is electroless nickel plated, provided as standard.

214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.

Free flow Controlled flow Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Model Port size Weight (g) AS420-02 2,500 1/4 38 3,600 55 0.34 AS420-03 5,000 3/8 77 4,800 74 0.33 63, 80, 100, 125 AS420-04 6,600 1/2 100 6,700 102 0.32 AS500-06 10,100 3/4 154 8,100 123 140, 160, 180, 200 0.36 AS600-10 15,100 1 230 16,900 258

1 Speed Exhaust Controller Series ASV Size: M3, M5, 1/8, 1/4, 3/8 How to Order Integration of a quick exhaust valve and an exhaust restrictor permits high-speed cylinder operation. 3 1 0 F 01 06 ASV S K Speed exhaust controller Option Nil None The effective area is two times larger.

MHS MHC Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F , which is the thrust of one finger, when both fingers and attachments are in full contact with the workpiece as shown in the figure below.

Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: T (Pressure Sensor, -100 to 100, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut), 1st Nominal Nozzle

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)

Stainless Steel Cylinder Se ries CJ5-S 10, 16 How to Order Bore size Standard stroke (mm) 10 16 10 16 10mm 16mm 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting Basic type Axial foot type Front flange type Double clevis type B L F D CJ5 L 16 S R 60 Without Auto Switch CDJ5 L 16 S R 60 H7BAL With Auto Switch With auto switch (built-in magnet) Number of