Stations: 6 Stations, Port Size: 1/4" One-touch Fitting, SI Unit: Device Net, -COM, Number of Input Blocks: Input Block 4 pcs., Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: Back Pressure Check Valves, DIN Rail Mounting Bracket w/o Din Rail, Option 2: Built-in Silencer, Direct Exhaust, US Option: Preferred US Option
Stations: 3 Stations, Port Size: ø8 One-touch Fitting, SI Unit: Device Net, -COM, Number of Input Blocks: Input Block 3 pcs., Input Block: M12, 4 Inputs, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: Name Plate, Option 2: None, US Option: Preferred US Option
Stations: 1 Station, Port Size: 1/4" One-touch Fitting, SI Unit: Device Net, -COM, Number of Input Blocks: Input Block 2 pcs., Input Block: M12, 4 Inputs, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: Built-in Silencer, Direct Exhaust, US Option: Preferred US Option
Stations: 2 Stations, Port Size: 1/4" One-touch Fitting, SI Unit: Device Net, -COM, Number of Input Blocks: Input Block 2 pcs., Input Block: M12, 4 Inputs, Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: Built-in Silencer, Direct Exhaust, US Option: Preferred US Option
Stations: 8 Stations, Port Size: Bottom Ported Elbow w/ø5/16" NPT One-touch Fitting, SI Unit: Device Net, -COM, Number of Input Blocks: w/o Input Block, Input Block: w/o Input Block (SD0), Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: Name Plate, Option 2: Built-in Silencer, Direct Exhaust, US Option: Preferred US Option
Stations: 2 Stations, Port Size: 1/4" One-touch Fitting, SI Unit: Device Net, -COM, Number of Input Blocks: Input Block 1 pc., Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: Name Plate, Option 2: Built-in Silencer, Direct Exhaust, US Option: Preferred US Option
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Base mount EX500 type plug-in manifold for VQC2000 valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Maximum 16 stations available as standard, Optional DIN rail mount, 18 port sizes available, MFLD, DEVICE NET, VALVE, VV5QC21 MANIFOLD VQC 5-PORT, 1P, VV5QC21 OTHER SIZE RATING, 3.30000 lb
8 129 251.5 275 285.5 9 139.5 262 287.5 298 10 150 272.5 300 310.2 11 160.5 283 312.5 323 12 171 293.5 325 335.5 13 181.5 304 325 335.5 14 192 314.5 337.5 348 15 202.5 325 350 360.5 16 213 335.5 362.5 373 17 223.5 346 375 385.5 18 234 356.5 387.5 398 19 244.5 367 387.5 398 20 255 377.5 400 410.5 21 265.5 388 412.5 423 22 276 398.5 425 435.5 23 286.5 409 437.5 448 24 297 419.5 450 448 VV5QC21
8 129 251.5 275 285.5 9 139.5 262 287.5 298 10 150 272.5 300 310.2 11 160.5 283 312.5 323 12 171 293.5 325 335.5 13 181.5 304 325 335.5 14 192 314.5 337.5 348 15 202.5 325 350 360.5 16 213 335.5 362.5 373 17 223.5 346 375 385.5 18 234 356.5 387.5 398 19 244.5 367 387.5 398 20 255 377.5 400 410.5 21 265.5 388 412.5 423 22 276 398.5 425 435.5 23 286.5 409 437.5 448 24 297 419.5 450 448 VV5QC21
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding
Base mount EX500 type plug-in manifold for VQC2000 valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Maximum 16 stations available as standard, Optional DIN rail mount, 18 port sizes available, MFLD, W/O SI UNIT (ELBOW FIT), VALVE, VV5QC21 MANIFOLD VQC 5-PORT, UP, VV5QC21 BUILT IN FITTING(
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has
Base mount EX500 type plug-in manifold for VQC2000 valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Maximum 16 stations available as standard, Optional DIN rail mount, 18 port sizes available VV5QC21 MANIFOLD VQC 5-PORT. VV5QC21 BUILT IN FITTING(>1/4). VALVE. VV5QC21 BUILT IN FITTING(>1/4). 3.00073 lb. WP.
Base mount EX500 type plug-in manifold for VQC2000 valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Maximum 16 stations available as standard, Optional DIN rail mount, 18 port sizes available VV5QC21 MANIFOLD VQC 5-PORT. VV5QC21 BUILT IN FITTING(>1/4). VALVE. VV5QC21 BUILT IN FITTING(>1/4). 1.87392 lb. WP.
VV5QC21 BUILT IN FITTINGLESS THAN 1/4). 2.86395 lb. UP.
VV5QC21 BUILT IN FITTING(>1/4). 1.98416 lb. WP.
Base mount EX500 type plug-in manifold for VQC2000 valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Maximum 16 stations available as standard, Optional DIN rail mount, 18 port sizes available VV5QC21 MANIFOLD VQC 5-PORT. VV5QC21 BUILT IN FITTING(>1/4). VALVE. VV5QC21 BUILT IN FITTING(>1/4). 1.92904 lb. WP.
Base mount EX500 type plug-in manifold for VQC2000 valves, Protective enclosure conforms to IP67 for protection from dust and moisture, Gateway type serial transmission system, Maximum 16 stations available as standard, Optional DIN rail mount, 18 port sizes available VV5QC21 MANIFOLD VQC 5-PORT. VV5QC21 BUILT IN FITTING(>1/4). VALVE. VV5QC21 BUILT IN FITTING(>1/4). 3.24079 lb. WP.