Series: 5 (VFA5000), Actuation: 4 (3 Position Exhaust Center), Body: 20, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 5 (3 Position Pressure Center), Body: 20, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 4 (3 Position Exhaust Center), Body: 20, A, B Port Size: 03 (3/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 1 (2 Position Single), Body: 20, A, B Port Size: 03 (3/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 3 (VFA3000), Actuation: 5 (3 Position Pressure Center), Body: 30, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 3 (VFA3000), Actuation: 4 (3 Position Exhaust Center), Body: 30, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 3 (VFA3000), Actuation: 1 (2 Position Single), Body: 30, A, B Port Size: 01 (1/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 3 (VFA3000), Actuation: 2 (2 Position Double), Body: 30, A, B Port Size: 01 (1/8), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 3 (VFA3000), Actuation: 2 (2 Position Double), Body: 30, A, B Port Size: 02 (1/4), Thread: T (NPTF), Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Series: 5 (VFA5000), Actuation: 2 (2 Position Double), Body: 44, Port Size: w/o Sub-plate, Pilot port: Rc, Thread: T (NPTF), Pilot Port Direction: P (Lateral)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket)
T Topology Connection configuration of the network -10No.EX-OMX1001 Installation and Wiring Installation Connect valve manifold to the SI unit.
[cm] -70No.PF-OMS0001CN-A PFMC7501/7102/7202 2x A B D E F H K L N PFMC7501/7102 Rc1/2NPT1/2 70 30 60.6 41.2 15 14 26 18 13.6 PFMC7202 Rc3/4NPT3/4G3/4 90 35 66.1 46.7 17.5 24 31 28 16.8 PFMC7501/7102 G1/2 76 30 60.6 41.2 15 14 26 18 13.6 S T U V W PFMC7501/7102 24 22 32 40 50 PFMC7202 30 30 42 48 58 -71No.PF-OMS0001CN-A M8 (ZS-40-A) -72No.PF-OMS0001CN-A Revision history A [September 2016]