Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 2 (Lateral), Valve Stations: 10 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 11
Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins, Entry Direction Adjustable), Connector Entry Direction: 2 (Lateral), Valve Stations: 11 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Manufacturer: 11 (YASKAWA Electric Corporation: MOTOMAN-HC10DT), Cup Series: ZP (Basic), Cup Diameter: 25 (ø25), Cup Form: C (Flat with Rib), Cup Material: N (NBR), Attachment: with (Guide) Attachment
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Manufacturer: 11 (YASKAWA Electric Corporation: MOTOMAN-HC10DT), Cup Series: ZP3P (Bellows Type for Film Packaging Workpieces), Cup Diameter: 25 (ø25), Cup Form: JT5 (5.5-stage Bellows), Cup Material: SF (Silicone Rubber, Blue), Attachment: with (Guide) Attachment
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Manufacturer: 11 (YASKAWA Electric Corporation: MOTOMAN-HC10DT), Cup Series: ZP (Basic), Cup Diameter: 25 (ø25), Cup Form: B (Bellows), Cup Material: N (NBR), Attachment: with (Guide) Attachment
(for std model)C85ISO cylinderC85Double acting, Single rodRefer to page 6-11-47.666
(for std model)C85ISO cylinderC85Double acting, Single rodRefer to page 6-11-47.666
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller.
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller.
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller.
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller.
N.O. 1/4 to 1 10 to 25 NEW Series VXH22 Series VX31/32/33 Series VX21/22/23 Brass Stainless steel Brass Stainless steel Brass NBR N.C. 1/4 to 1/2 10 For Air, Water, Oil Pilot Operated 2 Port Solenoid Valve for High Pressure For Air, Vacuum, Water, Steam, Oil Direct Operated 3 Port Solenoid Valve For Water, Oil, Steam, Air Direct Operated 2 Port Solenoid Valve Valve type Port size Body Seal
Assembly is required. 7 Technical Data Pressure dew point Condensed water calculation Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure
Fl 20 stafrons r (Not mounled) Base mounted / Type 40 (A porl: bottom porting) NVV3KF3-40-OD.01T stations^ --'11--t -o Applicable valves NVKF334O OOO Applicable blank plate ass'y vK300-42-1A 2 stations oplional accessory .
The speed can be changed by dragging the bar. (10) Distance of the pitch The distance of a pitch to move can be specified. (11) Pitch transfer The actuator moves through the specified pitch at the specified speed.
IDFA100F-40IDFA125F-40IDFA150F-40560 MPa 0.151.0 / K 0.151.6 () 245 (85%) 1 ) 860 1100 1340 m (ANR) 2 ) 875 1119 1363 3/h MPa 0.7 35 25 3 ) 3 (50Hz) kW 7.0 8.0 10.0 () 3 phase AC400V (50Hz) 4 ) kW 2.5 2.7 3.0 A 4.5 5.3 5.9 15 (30mA) 5 ) A R407C (HFC) (GWP: 1770) () V R2 R2 1/2 DIN 80 kg 245 270 350 1, 2 () kW 100 125 150 1(ANR)[2065%] 2[32] 3 4 5R 6.2 GWP (GWP)
R DIN DIN DIN DIN ISO#:EN ISO#:EN ISO#:EN ISO#:EN-175301 175301 175301 175301-803 803 803 803C C C C( ( ( ( DIN DIN DIN DIN 43650C)( 43650C)( 43650C)( 43650C)( 8mm) 8mm) 8mm) 8mm) DIN IP65() () 90 :3.57 ()JIS.C3306 0.5mm 2 3 1(p)3R2R5R1 3(R2 3(R2 3(R2 3(R2 R) R) R) R) 5(R1) 5(R1) 5(R1) 5(R1) 1 1 1 1 P P P P) ) ) ) VQZ100/1000 KQ2H06-M5 AN120-M5 KJS04-M5 VQZ200/2000 KQ2S06-01S INA-25
O: Sensor: OFF 1: Sensor: ON 3 Input block connector Connects the Input block. 12 8 Output block connector Connects the solenoid valve, Output block etc. 4 SW 1 5 13 9 Safety Instructions SI unit 5 Display window LED display shows the SI unit status. 2 6 14 10 HW 6 Switch protective cover Sets the address etc. with the switch inside. 31 29 27 25 23 17 3 7 21 19 15 11 Address setting mode
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller.
materials: NBR, Option: With light and surge voltage suppressor, Bracket: No bracket, Lead wire length(mm): 500, Lead wire electrical entry: DIN terminal (terminal pitch: 11 mm), Integrated pilot valve: 0.35‑W type (V116), Applicable switch: Without auto switch (without magnet), Number Of Switches: 2 pcs., Manual operation type: Non-locking, push type