Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 400 (4"), Stroke: 175 (1 3/4")

Series: NCA1 (Standard), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 3000 (30")

Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 400 (4")

Series: NCA1 (Standard), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 0200 (2")

Magnet: D (Built-in), Mounting: T (MT4, Center trunnion), Bore Size: 400 (4"), Stroke: 2000 (20"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)

Magnet: D (Built-in), Mounting: T (MT4, Center trunnion), Bore Size: 400 (4"), Stroke: 2000 (20"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs.

Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 5000 (50"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)

Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)

Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0800 (8"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)

Magnet: D (Built-in), Mounting: S (MS2, Side Lug), Bore Size: 400 (4"), Stroke: 0400 (4"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

100/400 100/400 100/400 100/400 100/400 100/400 100/400 100/100 100/100 100/200 100/200 100/200 100/200 100/200 100/200 100/100 100/100 100/100 ** Non-Standard Product, consult factory for lead time. * Dimension A reference after installation.

FV6 MV6 TW6 FV8 MV8 TW8 FV12 MV12 TW12 50 0.34 2.00 (50.8) 40 0.28 5.22 (132.6) 30 0.21 4.00 (101.6) 20 0.14 5.22 (132.6) 2.50 (63.5) 4.34 (110.2) 10 0.07 6.26 (159.0) 0 0.00 0 200 400 600 800 1000120014001600 1800 2000 Flow rate (slpm, N2) 5.00 (127.0) Hastelloy is a registered trademark of Haynes International.

bar unit MPa unit Surface finish No gauge port No code Seat material Surface finish Ra 10 in. (0.25 m) Standard 25 in. (0.62 m) Code No pressure gauge (Connections: 1/4 inch face seal male) 0 Code Material PCTFE (Standard) Vespel 3) PTFE 4) 5) No code Q No code VS TF V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400

Contents 150 NC1A150-PS 150 NC1A150-PS-XB5 200 NC1A200-PS-XB5 200 NC1A200-PS 250 NC1A250-PS 250 NC1A250-PS-XB5 325 NC1A325-PS 325 NC1A325-PS-XB5 400 NC1A400-PS 400 NC1A400-PS-XB5 Rod Option: Double Rod Option: Double, Special Option: Oversized Rod Bore Size (mm) Kit no. Contents Bore Size (mm) Kit no.

pressure (psig) 0.48 70 0.41 60 45 0.31 0.34 50 0.28 30 0.21 40 0.21 30 0.14 15 0.10 20 0.00 0.07 0 10 0 0.00 0 200 400 600 800 1000 Flow rate (slpm, N2) 0 400 800 1200 1600 2000 Flow rate (slpm, N2) ) If connection size differs, flow characteristics also differ. 55 High flow (Tied-diaphragm) Single Stage Regulator for General Applications Series AK9200 3/4 inch port size Inlet pressure

Applicable Controller Power Supply Voltage 100VAC Specification Series LJ1H10 Series LJ1H20 LJ1H1021H-K (8mm lead) LJ1H2021F-K (5mm lead) 250 400 225 350 12kg 6kg 200 300 175 250 Speed (mm/s) Speed (mm/s) 150 8kg 13kg 125 200 10kg 100 150 14kg 75 100 15kg 50 50 25 0 100 200 Stroke (mm) 300 400 0 100 200 300 400 500 600 Stroke (mm) When an actuator is operated under conditions that exceed

Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs.

Surface finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code 0 M V X Specification Standard Sub-atmospheric Code V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7

Magnet: D (Built-in), Mounting: T (Rear Trunnion), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: Rc, Stroke: 400mm, Rod Boot: None

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: Air cushion on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification