B RATE PWR L RUN SETTINGS MOD/NET ADDRESS NO. PWR PWR COM ERR ON ON L ERR.
Nil L/min oC Remote sensor G 1 L/min (gal/min) oC (oF) M L/min L oC G 1 gal/min gal oC Integrated display type F 1 gal/min gal oF J 1 L/min L oF Nil1 gal/min gal oC Integrated display type (IO-Link compatible) M L/min L oC : In accordance with the New Weights and Measures Act, use of the unit conversion function is not permitted in products for use in Japan.
Knuckle Pin (common with double clevis pin) Rod End Nut d d Dd9 C m l L t m t H B Material: Carbon steel mm Material: Rolled steel mm Part no. Applicable bore size (mm) 20 25 32, 40 50 Applicable bore size (mm) Snap ring l Part no.
Sensors (R) (P) 7.4 3 (13) M plug connector (M) L plug connector: 10-VQD1151-L-M5 M plug connector: 10-VQD1151-M-M5 5 5 5.5 2(B) 4(A) Direct manual override Lead wire length 300 mm 27 Indicator light 17.6 11.2 3 3(R) 9 0.3 3.8 10.9 3.5 5.5 9.1 2 x mounting hole 33.5 28.5 37 38 1(P) 1(P) 5.5 12 4-M5 x 0.8 13 L plug connector (L) (P, A, B, R port) 49 50.5 M plug connector (M) 598 4 Port Direct
Recommended shim thickness) Arm length L: 6 in 0.04 0.02 0.06 500 Clamping force (lbf) 400 0.7 MPa 300 0.5 MPa 0.3 MPa 200 100 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 186 Model Selection 2 Slim-line power clamp cylinder mounting 63 Arm length L: 200 mm 4000 Clamping force (N) 3000 CK1 CLK2 C(L)KQ MK2T/MK2/MK CKZ2N CKZT CLKZ1R CK/M(D)UKA 2000 1000 0 0 1 2 3 4 5 6 7 8 9 Shim
5.2 10 -44- LEYG / [Nm] [mm] M L M50.8 3.0 8 LEYG16 4 M L M61.0 5.2 11 LEYG25 / M L M61.0 5.2 12 LEYG32 [Nm] L[mm] M L M40.7 1.5 32 LEYG16 L M L M50.8 3.0 40.5 LEYG25 M L M50.8 3.0 50.5 LEYG32 / [Nm] [mm] M L M50.8 3.0 10 LEYG16 M L M61.0 5.2 12 LEYG25 M L M61.0 5.2 12 LEYG32 / [Nm] [mm] M L M40.7 1.5 7 LEYG16 M L M50.8 3.0 8 LEYG25 M L M61.0 5.2 10 LEYG32 LEY / 0.1mm / 0.05mm LEYG
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. DLead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.
ZSM PF2 IF Sensor Flow range Data 4 l/min 20 l/min 40 l/min 1.8 l/min 0.4 l/min 10 l/min 0.4 l/min 4 l/min PF2D504 4.5 l/min 0.25 l/min 1.8 l/min 20 l/min PF2D520 1.3 l/min 21 l/min 4 l/min 40 l/min PF2D540 2.5 l/min 45 l/min Rated flow rate range of sensor Set flow rate range of sensor 16-11-47
[particles/m3] Particle concentration [particles/m3] Suction flow rate: 30 L/min ISO Class 5 upper limit 10 10 ISO Class 5 upper limit 1000 1000 Suction flow rate: 30 L/min Suction flow rate: 60 L/min ISO Class 4 upper limit 100 100 Suction flow rate: 50 L/min ISO Class 4 upper limit 10 10 1 1 0 0.1 0.6 0.5 0.4 0.3 0.2 0 0.1 0.6 0.5 0.4 0.3 0.2 Particle diameter [m] Particle diameter [m]
(When L/A port1 LED is OFF.) L/A port1 or L/A port2 LEDs are OFF.
V W X E G T 0 0.1 D Width across flats K E Workpiece transfer direction 2 x N through 4 x O counterbore 2 x P (Rc, NPT, M thread) F Stroke Y Q S M L A + 2 stroke B + Stroke H + Stroke V G T 0 0.1 D E M L A + 2 stroke B + Stroke H + Stroke V Width across flats K Workpiece transfer direction 2 x P (Rc, NPT, G) F Z X Stroke S Q RSQB -DRZ (Double acting) 32 40 50 Bore size: 32, 40, 50 M E J
IODD file 1 1 ISE20B-L(-M)SMC-ISE20B-L-ymmdd-IODD1.1 2 ISE20B-L-PSMC-ISE20B-L-P-ymmdd-IODD1.1 3 ZSE20B-L(-M)SMC-ZSE20B-L-ymmdd-IODD1.1 4 ZSE20B-L-PSMC-ZSE20B-L-P-ymmdd-IODD1.1 5 ZSE20BF-L(-M)SMC-ZSE20BF-L-ymmdd-IODD1.1 6 ZSE20BF-L-PSMC-ZSE20BF-L-P-ymmdd-IODD1.1 1: "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.
IDX-OM-W022-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.
Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z : Manufactured upon receipt of order.
L RUN SERIAL UNIT L ERR.
limits, this will have an adverse effect on the life of the air gripper. 60 0.7MPa 0.6MPa 0.5MPa 0.3MPa 60 0.7MPa 0.4MPa 0.5MPa 0.6MPa 0.3MPa 0.4MPa 40 40 20 20 0 20 40 60 80 100 0 20 40 60 80 100 120 Gripping point L mm Gripping point L mm 36 Series MHZ2/MHZJ2 Model Selection Confirmation of external force on fingers: Series MHZ 2 Step 3 L L My Mr Mp Fv L L: Distance to the point at which
PNP open collector 2 outputs Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Panel mounting Specifications for Display Unit PF2D300/301 Model 0.25 to 4.5 l/min 1.3 to 21.0 l/min 2.5 to 45 l/min Flow rate measurement range Note 1) 0.25 to 4.5 l/min 1.3 to 21.0 l/min 2.5 to 45 l/min Set flow rate range Note 1) 0.05 l/min 0.1 l/min 0.5 l/min Minimum set unit Note 1) Accumulated
Knuckle pin (common with double clevis pin) Rod end nut d d Dd9 C m l L t m t H B Material: Carbon steel Material: Rolled steel (mm) (mm) Part no. Applicable bore size (mm) 20 25 32, 40 50, 63 80 100 Applicable bore size (mm) Snap ring l Part no.
Absorbed Energy Max. absorbed energy (J) Collision speed (m/s) Model 1 2 3 4 5 10 20 30 40 50 60 70 80 Soft type RJ0604 0.05 to 1 0.5 H : 0.05 to 2/L : 0.05 to 1 RJ0806H/L 1 H : 0.05 to 2/L : 0.05 to 1 RJ1007H/L 3 H : 0.05 to 2/L : 0.05 to 1 RJ1412H/L 10 H : 0.05 to 2/L : 0.05 to 1 RJ2015H/L 30 H : 0.05 to 1.5/L : 0.05 to 1 RJ2725H/L 70 Short stroke type RJ0805 0.05 to 1 0.5 RJ1006 0.05 to
EX600-ED2-l Handheld Terminal EX600-HT1A-l Power supply Model Power supplied from SI Unit connector (24 VDC) Current consumption 50 mA or less Display LCD with backlight Handheld Terminal cable (1 m EX600-AC010-1, 3 m EX600-AC030-1) Connection cable Enclosure IP20 Standards CE marking, RoHS recognition EX600-HT1A-l Weight 0.35 lbs (160 g) 8 Series EX600 Parts Description SI Unit w q e r